The Scleral Cap Technique for Porous and Nonporous Orbital Implants

被引:1
|
作者
Jordan, David R. [1 ,2 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Eye Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Ottawa Hosp, Eye Inst, 301 OConnor St, Ottawa, ON K2P 1V6, Canada
来源
关键词
ANOPHTHALMIC SOCKET; VICRYL-MESH; CORALLINE HYDROXYAPATITE; FIBROVASCULAR INGROWTH; ENUCLEATION SURGERY; AMERICAN-ACADEMY; EXPOSURE RATE; TRANSMISSION; COMPLICATIONS; EXPERIENCE;
D O I
10.1097/IOP.0000000000002299
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To describe the results and potential benefit of a banked homologous donor scleral cap over the anterior surface of polyglactin 910 mesh-wrapped porous and nonporous orbital implants during enucleation and secondary orbital implant surgery. Methods:This is a single center, retrospective, clinical case series of 83 patients who received a polyglactin 910 mesh (Vicryl knitted mesh, undyed, Ethicon, Sommerville, New Jersey, USA) wrapped bioceramic or polymethylmethacrylate orbital implant (sphere or mounded) following enucleation and secondary orbital implant surgery by one surgeon over a 10-year period. A homologous donor scleral cap (approximately 1.5 x 1.5 cm diameter) was also placed over the anterior mesh-wrapped implant surface as an additional barrier. A minimum of 1-year follow up was required to be included in the study. The author analyzed patient demographics, type of surgery, implant type, implant size, follow-up duration, and presence or absence of implant exposure. The data from patients with greater than 1-year follow up are detailed in this report. Results:The author identified 100 patients in his case files that had a scleral cap put in place over their implant. Seventeen patients were either lost to follow up or did not have at least a 1-year follow up, leaving 83 patients (44 enucleations, 39 secondary implants) that were followed for 12 to 120 months (average 60.5 months). There were no cases of implant exposure identified in either group of patients during this time period. Conclusions:Implant exposure can occur anytime post implant placement with a porous or nonporous orbital implant. This review suggests that a homologous donor scleral cap (approximately 1.5 x 1.5 cm diameter) over the polyglactin 910 mesh-wrapped implant surface may help prevent implant exposure. Patients with porous and nonporous orbital implants should be followed on a long-term basis as exposure can occur at anytime postsurgery, even several years later.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 50 条
  • [21] Porous polyethylene implants in orbital floor reconstruction
    Villarreal, PM
    Monje, F
    Morillo, AJ
    Junquera, LM
    González, C
    Barbón, JJ
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 109 (03) : 877 - 885
  • [22] Porous polyethylene implants in orbital floor reconstruction
    Lin, I-Chan
    Liao, Shu-Lang
    Lin, Luke L. K.
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2007, 106 (01) : 51 - 57
  • [23] Re: "Implant infection in porous orbital implants"
    Jordan, David R.
    Brownstein, Seymour
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (06): : 502 - 503
  • [24] Integrated Orbital Implants-A Comparison of Hydroxyapatite and Porous Polyethylene Implants
    Sadiq, S. Ahmed
    Mengher, Lakbir S.
    Lowry, John
    Downes, Richard
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2008, 27 (01): : 37 - 40
  • [25] Removal of MIRAgel Scleral Buckle Implants: The Direct Aspiration Technique
    Santorum, Paolo
    De Vitto, Antonia Maria Luce
    Bertelli, Enrico
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (10): : 2013 - 2017
  • [26] Primary banked scleral patch graft in the prevention of exposure of hydroxyapatite orbital implants
    Inkster, CF
    Ng, SGJ
    Leatherbarrow, B
    OPHTHALMOLOGY, 2002, 109 (02) : 389 - 392
  • [27] A SIMPLIFIED SCLERAL GRAFT TECHNIQUE FOR COVERING AN EXPOSED ORBITAL IMPLANT
    GOLDBERG, MF
    OPHTHALMIC SURGERY AND LASERS, 1988, 19 (03): : 206 - 211
  • [28] CLINICAL-EVALUATION OF POROUS AND NONPOROUS HYDROXYAPATITE IMPLANTS IN THE TREATMENT OF PERIODONTAL OSSEOUS DEFECTS
    KREJCI, C
    FARAH, C
    GREENWELL, H
    BISSADA, N
    JOURNAL OF DENTAL RESEARCH, 1987, 66 : 196 - 196
  • [29] Scanning electron microscopic examination of porous orbital implants
    Mawn, LA
    Jordan, DR
    Gilberg, S
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1998, 33 (04): : 203 - 209
  • [30] Experience with orbital implants in particular with porous hydroxyapatite materials
    Norda, AG
    Meyer-Rüsenberg, HW
    OPHTHALMOLOGE, 2003, 100 (06): : 437 - 444