Simultaneous Spectrofluorometric Determination of Fluoroquinolones Using Principal Component Analysis in Biological Samples

被引:1
|
作者
Hosseini, Firuzeh [1 ]
Naddaf, Ezzat [2 ]
Kakhki, Javad Fadaee [3 ]
Ebrahimi, Mahmoud [4 ]
机构
[1] Farhangian Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] Islamic Azad Univ, Dept Appl Chem, Mashhad Branch, Mashhad, Iran
[3] Police Sci & Social Studies Inst, Technol Management Dept, Tehran, Iran
[4] Islamic Azad Univ Mashhad, Dept Chem, Mashhad Branch, Mashhad, Iran
来源
CHEMICAL METHODOLOGIES | 2023年 / 7卷 / 05期
关键词
Fluoroquinolnes; Principal component; Artificial neural network; Partial least squares; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; ANTIBIOTICS; CALIBRATION; COMPLEXES; SEPARATION; FOODSTUFFS; POTASSIUM; WATERS;
D O I
10.22034/CHEMM.2023.379205.1637
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present work, a very sensitive, reliable, and simple spectrofluorometric procedure was improved for concurrent determination of ofloxacin, enrofloxacin, and levofloxacin in the absence of separation treads. Despite a spectral cover, a part of fluoroquinolones have been concurrently resolved by chemometric come near to involving principal component analysis artificial neural network and partial least squares. Artificial varieties mixtures of fluoroquinolones were evaluated and the results acquired by the implementations of these chemometric approaches were evaluated and compared. It was found that the principal component, artificial neural network method provided relatively better accuracy than that of PLS method. This method was applied satisfactorily for determining mixtures of fluoroquinolones in tilapia, chicken samples, and synthetic samples (with concentration ranging over 0.05-1.1 jig/mL for ofloxacin as well as 0.06-0.6 jig/mL and 0.01-0.23 jig/mL for enrofloxacin and levofloxacin), respectively. The suggested method enables detection limits of 0.04, 0.01, and 0.009 jig/mL for ofloxacin, enrofloxacin, and levofloxacin, correspondingly. The recoveries in the tilapia and chicken matrices ranged from 114% to 92%. All experiments that needed to be repeated were repeated 4 times.
引用
收藏
页码:348 / 357
页数:10
相关论文
共 50 条
  • [41] Simultaneous spectrofluorometric determination of piroxicam and pyridoxine using generalized rank annihilation method
    Abdollahi, H
    Sororaddin, MH
    Naseri, A
    ANALYTICAL SCIENCES, 2006, 22 (02) : 263 - 267
  • [42] Determination of femoral artery occlusion using principal component analysis of Doppler signals
    Kara, S
    Kemaloglu, S
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2005, 33 (03) : 329 - 338
  • [43] Simultaneous determination of trace uranium and vanadium in biological samples by radiochemical neutron activation analysis
    Repinc, U
    Benedik, L
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (01) : 77 - 81
  • [44] Simultaneous determination of trace uranium and vanadium in biological samples by radiochemical neutron activation analysis
    U. Repinc
    L. Benedik
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 77 - 81
  • [45] SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE IN BIOLOGICAL SAMPLES BY MULTICHANNEL FLOW-INJECTION ANALYSIS
    PRATT, PF
    NITHIPATIKOM, K
    CAMPBELL, WB
    ANALYTICAL BIOCHEMISTRY, 1995, 231 (02) : 383 - 386
  • [46] Multiresolution using principal component analysis
    Brennan, V
    Principe, J
    2000 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, PROCEEDINGS, VOLS I-VI, 2000, : 3474 - 3477
  • [47] SIMULTANEOUS DETERMINATION OF IODINE AND SELENIUM IN BIOLOGICAL SAMPLES BY RADIOCHEMICAL NEUTRON-ACTIVATION ANALYSIS
    DERMELJ, M
    STIBILJ, V
    STEKAR, J
    BYRNE, AR
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (04): : 258 - 261
  • [48] Simultaneous Spectrofluorometric Determination of Piroxicam and Pyridoxine Using Generalized Rank Annihilation Method
    Hamid Abdollahi
    Mohammad Hossein Sororaddin
    Abdolhossein Naseri
    Analytical Sciences, 2006, 22 : 263 - 267
  • [49] Data Analysis Using Principal Component Analysis
    Sehgal, Shrub
    Singh, Harpreet
    Agarwal, Mohit
    Bhasker, V.
    Shantanu
    2014 INTERNATIONAL CONFERENCE ON MEDICAL IMAGING, M-HEALTH & EMERGING COMMUNICATION SYSTEMS (MEDCOM), 2015, : 45 - 48
  • [50] Simultaneous determination of iodate and periodate by kinetic spectrophotometric method using principal component artificial neural network
    Benvidi, A.
    Heidari, F.
    Tabaraki, R.
    Mazloum-Ardakani, Mohammad
    JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (07) : 661 - 668