A Deep Learning Model for Automated Segmentation of Geographic Atrophy Imaged Using Swept-Source OCT

被引:11
|
作者
Pramil, Varsha [1 ,2 ]
de Sisternes, Luis [3 ]
Omlor, Lars [3 ]
Lewis, Warren [3 ,4 ]
Sheikh, Harris [2 ]
Chu, Zhongdi [5 ]
Manivannan, Niranchana [3 ]
Durbin, Mary [6 ]
Wang, Ruikang K. [5 ]
Rosenfeld, Philip J. [7 ]
Shen, Mengxi [7 ]
Guymer, Robyn [8 ]
Liang, Michelle C. [1 ,2 ]
Gregori, Giovanni [7 ]
Waheed, Nadia K. [1 ,2 ,9 ]
机构
[1] Tufts Univ, Sch Med, Boston, MA USA
[2] Tufts Univ New England Med Ctr, New England Eye Ctr, Boston, MA USA
[3] Carl Zeiss Meditec Inc, California, Dublin, Ireland
[4] Bayside Photon Inc, Yellow Springs, OH USA
[5] Univ Washington Seattle, Dept Biomed Engn, Seattle, WA USA
[6] Heru Inc, Miami, FL USA
[7] Univ Miami Miller, Bascom Palmer Eye Inst, Sch Med, Miami, FL USA
[8] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, Dept Surg Ophthalmol, Melbourne, Australia
[9] New England Eye Ctr, 260 Tremont St,9th Floor, Boston, MA 02116 USA
来源
OPHTHALMOLOGY RETINA | 2023年 / 7卷 / 02期
基金
美国国家卫生研究院;
关键词
Automated algorithm; Deep learning; Geographic atrophy; SS-OCT; Swept-source OCT; OPTICAL COHERENCE TOMOGRAPHY; MACULAR DEGENERATION; END-POINTS; PROGRESSION; SECONDARY; VALIDATION;
D O I
10.1016/j.oret.2022.08.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To present a deep learning algorithm for segmentation of geographic atrophy (GA) using en face swept-source OCT (SS-OCT) images that is accurate and reproducible for the assessment of GA growth over time.Design: Retrospective review of images obtained as part of a prospective natural history study.Subjects: Patients with GA (n = 90), patients with early or intermediate age-related macular degeneration (n = 32), and healthy controls (n = 16).Methods: An automated algorithm using scan volume data to generate 3 image inputs characterizing the main OCT features of GAdhypertransmission in subretinal pigment epithelium (sub-RPE) slab, regions of RPE loss, and loss of retinal thicknessdwas trained using 126 images (93 with GA and 33 without GA, from the same number of eyes) using a fivefold cross-validation method and data augmentation techniques. It was tested in an independent set of one hundred eighty 6 x 6-mm2 macular SS-OCT scans consisting of 3 repeated scans of 30 eyes with GA at baseline and follow-up as well as 45 images obtained from 42 eyes without GA.Main Outcome Measures: The GA area, enlargement rate of GA area, square root of GA area, and square root of the enlargement rate of GA area measurements were calculated using the automated algorithm and compared with ground truth calculations performed by 2 manual graders. The repeatability of these measure-ments was determined using intraclass coefficients (ICCs).Results: There were no significant differences in the GA areas, enlargement rates of GA area, square roots of GA area, and square roots of the enlargement rates of GA area between the graders and the automated algorithm. The algorithm showed high repeatability, with ICCs of 0.99 and 0.94 for the GA area measurements and the enlargement rates of GA area, respectively. The repeatability limit for the GA area measurements made by grader 1, grader 2, and the automated algorithm was 0.28, 0.33, and 0.92 mm2, respectively.Conclusions: When compared with manual methods, this proposed deep learning-based automated algo-rithm for GA segmentation using en face SS-OCT images was able to accurately delineate GA and produce reproducible measurements of the enlargement rates of GA. Ophthalmology Retina 2023;7:127-141 (c) 2022 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:127 / 141
页数:15
相关论文
共 50 条
  • [31] Correlations Between Choriocapillaris and Choroidal Measurements and the Growth of Geographic Atrophy Using Swept Source OCT Imaging
    Shi, Yingying
    Zhang, Qinqin
    Zhou, Hao
    Wang, Liang
    Chu, Zhongdi
    Jiang, Xiaoshuang
    Shen, Mengxi
    Thulliez, Marie
    Lyu, Cancan
    Feuer, William
    de Sisternes, Luis
    Durbin, Mary K.
    Gregori, Giovanni
    Wang, Ruikang K.
    Rosenfeld, Philip J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 224 : 321 - 331
  • [32] Measuring central macular thickness in diabetes using swept-source OCT
    Aitchison, Ross Thomas
    Kennedy, Graeme J.
    Shu, Xinhua
    Mansfield, David C.
    Shahani, Uma
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [33] Comparative analysis of 2 biometers using swept-source OCT technology
    Panthier, Christophe
    Rouger, Helene
    Gozlan, Yoni
    Moran, Sarah
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (01): : 26 - 31
  • [34] Reproducibility of automated choroidal thickness measurements: swept-source OCT and spectral-domain OCT using enhanced depth imaging
    Zhang, Li
    Abramoff, Michael David
    Waldstein, Sebastian M.
    Gerendas, Bianca
    Glodan, Ana-Maria
    Simader, Christian
    Schmidt-Erfurth, Ursula
    Sonka, Milan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [35] Swept-source OCT using pulsed mid-infrared light
    Lin, Wai Ching
    Matcher, Stephen J.
    LABEL-FREE BIOMEDICAL IMAGING AND SENSING (LBIS) 2019, 2019, 10890
  • [36] Retinal Arteriovenous Malformation Assessment Using Swept-Source OCT Angiography
    Chawla, Rohan
    Pujari, Amar
    Mittal, Kanhaiya
    Rakheja, Vaishali
    Markan, Ashish
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2018, 49 (03): : 216 - 219
  • [37] Posterior Vitreous Assessment in Pneumatic Retinopexy using Swept-Source OCT
    Melo, Isabela Martins
    Shor, Reut
    Oquendo, Paol
    Muni, Rajeev H.
    Wong, David T.
    OPHTHALMOLOGY RETINA, 2023, 7 (08): : 737 - 739
  • [38] A unified deep learning model for geographic atrophy segmentation: Adaptable to SS-OCT and SD-OCT data with multiple scan patterns
    Zhang, Qinqin
    Herrera, Gissel
    Shen, Mengxi
    Gregori, Giovanni
    Rosenfeld, Philip J.
    Salehi, Ali
    Manivannan, Niranchana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [39] Automated Segmentation of Microvessels in Intravascular OCT Images Using Deep Learning
    Lee, Juhwan
    Kim, Justin N. N.
    Gomez-Perez, Lia
    Gharaibeh, Yazan
    Motairek, Issam
    Pereira, Gabriel T. R.
    Zimin, Vladislav N. N.
    Dallan, Luis A. P.
    Hoori, Ammar
    Al-Kindi, Sadeer
    Guagliumi, Giulio
    Bezerra, Hiram G. G.
    Wilson, David L. L.
    BIOENGINEERING-BASEL, 2022, 9 (11):
  • [40] Anterior segment dewarping using swept-source OCT (SS-OCT) cube scans
    Tate, Nelson
    Bagherinia, Homayoun
    Nafar, Zahra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)