Would lead shielding the eye lenses during a head CT be beneficial?

被引:0
|
作者
Alqahtani, F. F. [1 ,2 ]
Saeed, M. K. [1 ]
Abdallah, Y. [3 ]
Alshamrani, K. [1 ]
机构
[1] Najran Univ, Appl Med Sci Coll, Dept Radiol Sci, Najran, Saudi Arabia
[2] Najran Univ, Hlth Res Ctr, Najran, Saudi Arabia
[3] Majmaah Univ, Coll Appl Med Sci, Dept Radiol Sci & Med Imaging, Al Majmaah 11952, Saudi Arabia
关键词
eye lenses; computed tomography; lead shielding; phantom; RADIATION-DOSE REDUCTION; SUPERFICIAL ORGANS; CURRENT MODULATION; IMAGE QUALITY; CATARACT; PROTECTION; RISK;
D O I
10.1051/radiopro/2023014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The lens of the eye is one of the radiosensitive organs. Patients receiving computed tomography (CT) scanning of the head, as well as patients undergoing repeated CT scanning of the head, are at risk for this consequence. The goal of this study was to see if a lead equivalent might reduce radiation reaching the eye's lens during regular cranial CT. The goal was accomplished by determining the ideal shielding thickness for patient applications by first evaluating the image quality using phantom measurements taken with and without lead shielding. LiF-thermoluminescent dosimeters were used to quantify the entrance surface doses (ESDs) to the eye lenses of the ATOM phantom without, with one, two, and three layers of lead shielding. The use of customized lead shields up to 0.1 mm thick might be used, according to ACR CT Phantom studies, without having a noticeable impact on the image quality for the central and posterior areas. In these experiments, 0.1 mm thick lead shielding reduces ESDs to the eye's lens by 31%. Eye shields significantly reduced image quality in the anterior region, but just slightly in the centre and posterior regions. Given the foregoing, using modified lead shields could drastically lower dose to the lens without severely affecting image quality.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 50 条
  • [21] Computed tomography of the head: An experimental study to investigate the effectiveness of lead shielding during three scanning protocols
    Williams, Lisa
    Adams, Caroline
    RADIOGRAPHY, 2006, 12 (02) : 143 - 152
  • [22] Neonatal Eye Shielding during Phototherapy: What Protects the Eye Better?
    Abdulkadir, Isa
    Slusher, Tina M.
    JOURNAL OF TROPICAL PEDIATRICS, 2021, 67 (06)
  • [23] APPLICATION OF GAFCHROMIC FILMS FOR THE EVALUATION OF LEAD EYE SHIELDING EFFICIENCY DURING SUPERFICIAL X-RAY TREATMENT
    Medvedevas, Nikolajus
    Rutkauskaite, Inga
    Adliene, Diana
    Laurikaitiene, Jurgita
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 84 - +
  • [24] Usefulness of a lead shielding device for reducing the radiation dose to tissues outside the primary beams during CT
    Jae-Joon Chung
    Eun-Suk Cho
    Sung Min Kang
    Jeong-Sik Yu
    Dae Jung Kim
    Joo Hee Kim
    La radiologia medica, 2014, 119 : 951 - 957
  • [25] Breast Surface Radiation Dose During Coronary CT Angiography: Reduction by Breast Displacement and Lead Shielding
    Foley, Shane J.
    McEntee, Mark F.
    Achenbach, Stephan
    Brennan, Patrick C.
    Rainford, Louise S.
    Dodd, Jonathan D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : 367 - 373
  • [26] Usefulness of a lead shielding device for reducing the radiation dose to tissues outside the primary beams during CT
    Chung, Jae-Joon
    Cho, Eun-Suk
    Kang, Sung Min
    Yu, Jeong-Sik
    Kim, Dae Jung
    Kim, Joo Hee
    RADIOLOGIA MEDICA, 2014, 119 (12): : 951 - 957
  • [27] Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head: A Monte Carlo study
    Perisinakis, K
    Raissaki, M
    Tzedakis, A
    Theocharopoulos, N
    Damilakis, J
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2005, 32 (04) : 1024 - 1030
  • [28] Eye and head coordination during reading
    Proudlock, FA
    Shekhar, H
    Gottlob, I
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U212 - U212
  • [29] Do diffractive intraocular lenses break the beneficial interaction between chromatic and monochromatic aberrations in the eye?
    Clave, Laura
    Millan, Maria s.
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (12): : 6977 - 6988
  • [30] Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures
    Hu, Panpan
    Kong, Yan
    Chen, Bo
    Liu, Qianqian
    Zhuo, Weihai
    Liu, Haikuan
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (01) : 136 - 140