A Comparative Study of Shade-Matching Reproducibility Using an Intraoral Scanner and a Spectrophotometer

被引:2
|
作者
Floriani, Franciele [1 ]
Jurado, Carlos A. [2 ]
Abuhammoud, Salahaldeen [1 ]
Vargas, Marcos [3 ]
Fischer, Nicholas G. [4 ]
Rojas-Rueda, Silvia [5 ]
Lopes, Guilherme Carpena [6 ]
机构
[1] Univ Iowa, Coll Dent & Dent Clin, Dept Prosthodont, Iowa City, IA 52242 USA
[2] Univ Tennessee, Hlth Sci Ctr, Coll Dent, Div Operat Dent,Dept Gen Dent, Memphis, TN 38103 USA
[3] Univ Iowa, Coll Dent & Dent Clin, Dept Family Dent, Iowa City, IA 52242 USA
[4] Univ Minnesota, Sch Dent, Minnesota Dent Res Ctr Biomat & Biomech, Minneapolis, MN 55108 USA
[5] Univ Javeriana, Sch Dent, Bogota 110231, Colombia
[6] Univ Fed Santa Catarina, Coll Dent, BR-88040900 Florianopolis, SC, Brazil
关键词
shade matching; color; color stability; intraoral scanner; spectrophotometer; COLOR STABILITY; TOOTH COLOR; BULK;
D O I
10.3390/dj12030062
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: We compared the repeatability of the shade determination of resin composite restorations and acrylic teeth in light and darker shades at baseline and after an aging process through two digital tooth color-matching methods: using a Trios 3Shape intraoral scanner and using a Vita Easyshade Compact spectrophotometer. Material and Methods: Forty upper central incisor acrylic teeth in the shade A1 (n = 10) and A3 (n = 10) were randomly assigned to be restored with Filtek Bulk Fill in the shade A1 (n = 10) or A3 (n = 10). Subsequently, 20 Class V cavities were prepared in a standardized manner (mesio-distal = 3.0 mm, cervical-occlusal = 2.0 mm, depth = 1.5 mm). Cavities were restored using an universal adhesive system and resin composite in two increments and were light-cured. The shade difference between the resin composite Class V restorations in acrylic teeth of the A1 and A3 shades was evaluated at baseline and after aging. Aging was simulated using ultraviolet light for 120 h. An Easyshade device and an intraoral scanner were used under D65 illumination. Measurements were taken five times, on top of the restoration and on the acrylic teeth, in a randomized manner. Results: Data analysis was on the calculation of the arithmetic mean for the percentage of repeatability conducted by the Trios scanner and the Easyshade device. There was no statistically significant comparison between the shade measurement devices (p > 0.05). At baseline, the repeatability for both the Trios intraoral scanner and the Vita Easyshade Compact device for artificial teeth in the shades A1 and A3 was 100%. After aging, the trueness recorded by the intraoral scanner and the Easyshade device for artificial teeth in the shade A1 was 80%. For Class V restoration with shade A1, the intraoral scanner recorded 80% trueness and the Easyshade device recorded 60% trueness at baseline. For shade A3, the intraoral scanner recorded 60% trueness and the Easyshade device recorded 60% trueness. Conclusions: The intraoral scanner and Easyshade device are reliable for baseline shade selection, but their accuracy decreases after aging, particularly for darker shades.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Reliability of qualitative occlusal tooth wear evaluation using an intraoral scanner: A pilot study
    da Rosa Moreira Bastos, Renata Travassos
    da Silva, Priscila Teixeira
    Normando, David
    PLOS ONE, 2021, 16 (03):
  • [42] Comparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study
    Ferrini, Francesco
    Mazzoleni, Federica
    Barbini, Matteo
    Coppo, Carlotta
    Di Domenico, Giovanna Laura
    Gherlone, Enrico Felice
    PROSTHESIS, 2024, 6 (02): : 401 - 412
  • [43] Comparative Analysis of Three Different Impression Techniques for Impression Defects and Dimensional Accuracy Using a Digital Intraoral Scanner for Fixed Partial Dentures: An In Vivo Study
    Khatuja, Neha G.
    Katiyar, Pratibha
    Tarannum, Fauzia
    Pandey, Kaushik Kumar
    Katiyar, Abhishek Kumar
    Afzal, Zoya
    Ali, Aman
    Roy, Ispita
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [44] Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
    Kernen, Florian
    Braendle, Dominik
    Wagendorf, Oliver
    Recca, Mario
    Mehrhof, Juergen
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (08) : 793 - 801
  • [45] Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner
    Rcch-Ortega, Cristina
    Fernandez-Estevan, Lucia
    Fernanda Sola-Ruiz, Ma
    Agustin-Panadero, Ruben
    Labaig-Rueda, Carlos
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (01): : E89 - E95
  • [46] Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study
    Hauschild, Uli
    Lerner, Henriette
    Weigl, Paul
    Porra, Tommaso
    Admakin, Oleg
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 150
  • [47] Detection of Erosive Changes on Smooth Surfaces with and without Orthodontic Brackets Using an Intraoral Scanner-An In Vitro Study
    Jablonski-Momeni, Anahita
    Hanselmann, Franka
    Bottenberg, Peter
    Korbmacher-Steiner, Heike
    DIAGNOSTICS, 2023, 13 (20)
  • [48] In vivo prospective randomised study of the wear of dental restorations using an intraoral scanner and its correlation with visual assessment
    Moreno, Nerea Urcelay
    Gessi, Sabina Francesca Bertuol
    M'Rabat, Meriem Benabdallah
    Thuissard, Israel John
    Santamaria-Laorden, Andrea
    JOURNAL OF DENTISTRY, 2025, 153
  • [49] Accuracy of Implant-Supported Copy Overdentures Fabricated Using Either an Intraoral Scanner and a 3D Printer or the Conventional Copy Denture Technique: A Comparative Study
    Tanaka, Jyoji
    Murakami, Takahiro
    Tanaka, Shinji
    Kanno, Takeshi
    Imada, Yuya
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 989 - 996
  • [50] Comparative study of shade matching performance of dental students under natural day light and day light lamp conditions
    Mete, Jitendra J.
    Mange, Shankar P.
    Khalikar, Arun N.
    Vaidya, Smita P.
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2013, 8 (02): : 192 - 199