Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping

被引:5
|
作者
Ludwig, Juliane [1 ]
Kerkering, Kirsten Miriam [1 ]
Speier, Peter [2 ]
Schaeffter, Tobias [3 ]
Kolbitsch, Christoph [1 ]
机构
[1] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[2] Siemens Healthcare, Erlangen, Germany
[3] Tech Univ Berlin, Dept Biomed Engn, Berlin, Germany
关键词
Prospective respiratory motion correction; T1; mapping; Pilot tone; Cardiovascular MR; MAGNETIC-RESONANCE; INVERSION-RECOVERY; T-1; MOLLI; REGISTRATION; RELAXATION; COIL; MRI;
D O I
10.1007/s10334-022-01032-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To provide respiratory motion correction for free-breathing myocardial T1 mapping using a pilot tone (PT) and a continuous golden-angle radial acquisition. Materials and methods During a 45 s prescan the PT is acquired together with a dynamic sagittal image covering multiple respiratory cycles. From these images, the respiratory heart motion in head-feet and anterior-posterior direction is estimated and two linear models are derived between the PT and heart motion. In the following scan through-plane motion is corrected prospectively with slice tracking based on the PT. In-plane motion is corrected for retrospectively. Our method was evaluated on a motion phantom and 11 healthy subjects. Results Non-motion corrected measurements using a moving phantom showed T1 errors of 14 +/- 4% (p < 0.05) compared to a reference measurement. The proposed motion correction approach reduced this error to 3 +/- 4% (p < 0.05). In vivo the respiratory motion led to an overestimation of T1 values by 26 +/- 31% compared to breathhold T1 maps, which was successfully corrected to an average difference of 3 +/- 2% (p < 0.05) between our free-breathing approach and breathhold data. Discussion Our proposed PT-based motion correction approach allows for T1 mapping during free-breathing with the same accuracy as a corresponding breathhold T1 mapping scan.
引用
收藏
页码:135 / 150
页数:16
相关论文
共 50 条
  • [41] A Novel Technique for Respiratory Motion Correction in Rapid Left Ventricular Myocardial T1 Mapping and Quantitative Analysis of Myocardial Fibrosis
    Kawaji, Keigo
    Marino, Marco
    Tanaka, Akiko
    Tarroni, Giacomo
    Ota, Takeyoshi
    Lang, Roberto M.
    Patel, Amit R.
    CIRCULATION, 2014, 130
  • [42] Respiratory motion correction in free-breathing ultrasound image sequence for quantification of hepatic perfusion
    Zhang, Ji
    Ding, Mingyue
    Meng, Fan
    Yuchi, Ming
    Zhang, Xuming
    MEDICAL PHYSICS, 2011, 38 (08) : 4737 - 4748
  • [43] Free-Breathing Combined Three-Dimensional Phase Sensitive Late Gadolinium Enhancement and T1 Mapping for Myocardial Tissue Characterization
    Weingaertner, Sebastian
    Akcakaya, Mehmet
    Roujol, Sebastien
    Basha, Tamer
    Tschabrunn, Cory
    Berg, Sophie
    Anter, Elad
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 1032 - 1041
  • [44] Prospective correction of patient-specific respiratory motion in myocardial T1and T2mapping
    Bush, Michael A.
    Pan, Yue
    Jin, Ning
    Liu, Yingmin
    Varghese, Juliet
    Ahmad, Rizwan
    Simonetti, Orlando P.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (02) : 855 - 867
  • [45] Free-breathing T2*mapping for MR myocardial iron assessment at 3 T
    Nazarova, E. E.
    Tereshchenko, G., V
    Kupriyanov, D. A.
    Smetanina, N. S.
    Novichkova, G. A.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [46] Free-breathing T2* mapping for MR myocardial iron assessment at 3 T
    E. E. Nazarova
    G. V. Tereshchenko
    D. A. Kupriyanov
    N. S. Smetanina
    G. A. Novichkova
    European Radiology Experimental, 4
  • [47] Free-breathing, non-ECG, simultaneous myocardial T1, T2, T2, and fat-fraction mapping with motion-resolved cardiovascular MR multitasking
    Cao, Tianle
    Wang, Nan
    Kwan, Alan C.
    Lee, Hsu-Lei
    Mao, Xianglun
    Xie, Yibin
    Nguyen, Kim-Lien
    Colbert, Caroline M.
    Han, Fei
    Han, Pei
    Han, Hui
    Christodoulou, Anthony G.
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1748 - 1763
  • [48] Evaluation of a free-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging in patient
    Jihye Jang
    Sébastien Roujol
    Tamer A Basha
    Shingo Kato
    Sophie Berg
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [49] Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model
    Manke, D
    Nehrke, K
    Börnert, P
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 122 - 131
  • [50] Fast Algorithm for Respiratory Motion Correction in Free-Breathing Contrast-Enhanced Ultrasound Imaging
    Zhang, Ji
    Ding, Mingyue
    Meng, Fan
    Ming Yuchi
    MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968