Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping

被引:5
|
作者
Ludwig, Juliane [1 ]
Kerkering, Kirsten Miriam [1 ]
Speier, Peter [2 ]
Schaeffter, Tobias [3 ]
Kolbitsch, Christoph [1 ]
机构
[1] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[2] Siemens Healthcare, Erlangen, Germany
[3] Tech Univ Berlin, Dept Biomed Engn, Berlin, Germany
关键词
Prospective respiratory motion correction; T1; mapping; Pilot tone; Cardiovascular MR; MAGNETIC-RESONANCE; INVERSION-RECOVERY; T-1; MOLLI; REGISTRATION; RELAXATION; COIL; MRI;
D O I
10.1007/s10334-022-01032-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To provide respiratory motion correction for free-breathing myocardial T1 mapping using a pilot tone (PT) and a continuous golden-angle radial acquisition. Materials and methods During a 45 s prescan the PT is acquired together with a dynamic sagittal image covering multiple respiratory cycles. From these images, the respiratory heart motion in head-feet and anterior-posterior direction is estimated and two linear models are derived between the PT and heart motion. In the following scan through-plane motion is corrected prospectively with slice tracking based on the PT. In-plane motion is corrected for retrospectively. Our method was evaluated on a motion phantom and 11 healthy subjects. Results Non-motion corrected measurements using a moving phantom showed T1 errors of 14 +/- 4% (p < 0.05) compared to a reference measurement. The proposed motion correction approach reduced this error to 3 +/- 4% (p < 0.05). In vivo the respiratory motion led to an overestimation of T1 values by 26 +/- 31% compared to breathhold T1 maps, which was successfully corrected to an average difference of 3 +/- 2% (p < 0.05) between our free-breathing approach and breathhold data. Discussion Our proposed PT-based motion correction approach allows for T1 mapping during free-breathing with the same accuracy as a corresponding breathhold T1 mapping scan.
引用
收藏
页码:135 / 150
页数:16
相关论文
共 50 条
  • [21] Deep-Learning based Motion Correction for Myocardial T1 Mapping
    Arava, Dar
    Masarwy, Mohammad
    Khawaled, Samah
    Freiman, Moti
    2021 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, ANTENNAS, COMMUNICATIONS AND ELECTRONIC SYSTEMS (COMCAS), 2021, : 55 - 59
  • [22] Exploiting Quasiperiodicity in Motion Correction of Free-Breathing Myocardial Perfusion MRI
    Wollny, Gert
    Ledesma-Carbayo, Maria J.
    Kellman, Peter
    Santos, Andres
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (08) : 1516 - 1527
  • [23] Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle
    Yon Mi Sung
    Hwanseok Yong
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [24] Free-breathing abdominal T1 mapping using an optimized MR fingerprinting sequence
    van Riel, Max H. C.
    Yu, Zidan
    Hodono, Shota
    Xia, Ding
    Chandarana, Hersh
    Fujimoto, Koji
    Cloos, Martijn A.
    NMR IN BIOMEDICINE, 2021, 34 (07)
  • [25] Reproducibility of free-breathing multi-slice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence
    Jihye Jang
    Sébastien Roujol
    Sebastian Weingärtner
    Tamer A Basha
    Sophie Berg
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [26] Accelerated 3D free-breathing high-resolution myocardial T1ρ mapping at 3 Tesla
    Qi, Haikun
    Lv, Zhenfeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2520 - 2531
  • [27] Free breathing motion-corrected T1 mapping for robust assessment of myocardial injury post myocardial infarction
    Nazir, Sheraz A.
    Khan, Jamal N.
    McCann, Gerry P.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01): : 123 - 124
  • [28] Free breathing motion-corrected T1 mapping for robust assessment of myocardial injury post myocardial infarction
    Sheraz A. Nazir
    Jamal N. Khan
    Gerry P. McCann
    The International Journal of Cardiovascular Imaging, 2015, 31 : 123 - 124
  • [29] Fast myocardial T1 mapping using cardiac motion correction
    Becker, Kirsten M.
    Blaszczyk, Edyta
    Funk, Stephanie
    Nuesslein, Andre
    Schulz-Menger, Jeanette
    Schaeffter, Tobias
    Kolbitsch, Christoph
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 438 - 451
  • [30] Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping
    Le, Johnathan V.
    Mendes, Jason K.
    Sideris, Konstantinos
    Bieging, Erik
    Carter, Spencer
    Stehlik, Josef
    Dibella, Edward V. R.
    Adluru, Ganesh
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,