Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?

被引:0
|
作者
Cetinkaya, Zeki [1 ]
Elcik, Deniz [2 ]
Kelesoglu, Saban [2 ]
Cesur, Burak [3 ]
Yasan, Mustafa [4 ]
Karabiyik, Ugur [5 ]
Bingol, Bilge [6 ]
Kalay, Nihat [2 ]
Topsakal, Ramazan [2 ]
Tuncay, Aydin [7 ]
Dogan, Ali [2 ]
Inanc, Mehmet Tugrul [2 ]
机构
[1] Elazig Fethi Sekin City Hosp, Dept Cardiol, Elazig, Turkiye
[2] Erciyes Univ, Fac Med, Dept Cardiol, Kayseri, Turkiye
[3] Kayseri State Hosp, Dept Cardiol, Kayseri, Turkiye
[4] Kastamonu Training & Res Hosp, Dept Cardiol, Kastamonu, Turkiye
[5] Nigde Training & Res Hosp, Dept Cardiol, Nigde, Turkiye
[6] Kirsehir Training & Res Hosp, Dept Cardiol, Kirsehir, Turkiye
[7] Erciyes Univ, Dept Cardiovasc Surg, Fac Med, Kayseri, Turkiye
关键词
Transcatheter aortic valve implantation; bundle branch block; AV block; atrial-his interval; REPLACEMENT; STENOSIS; BLOCK; PROSTHESIS;
D O I
10.55730/1300-0144.5750
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: Despite advancements in valve technology and increased clinical experience, complications related to conduction defects after transcatheter aortic valve implantation (TAVR) have not improved as rapidly as expected. In this study, we aimed to predict the development of complete atrioventricular (AV) block and bundle branch block during and after the TAVR procedure and to investigate any changes in the cardiac conduction system before and after the procedure using electrophysiological study.Materials and methods: A total of 30 patients who were scheduled for TAVR at our cardiovascular council were planned to be included in the study. TAVR was performed on patients at Erciyes University Medical Faculty Hospital as a single center between May 2019 and August 2020 Diagnostic electrophysiological study was performed before the TAVR procedure and after its completion. Changes in the cardiac conduction system during the preprocedure, intra-procedure, and postprocedure periods were recorded.Results: Significant increases in baseline cycle length, atrial-His (AH) interval, his-ventricular (HV) interval and atrioventricular (AV) distance were observed before and after the TAVR procedure (p = 0.039, p < 0.001, p = 0.018, p < 0.001, respectively). During the TAVR procedure, the preprocedural HV interval was longer in patients who developed AV block and bundle branch block compared to those who did not and this difference was statistically significant (p = 0.024). ROC curve analysis revealed that a TAVR preprocedure HV value >59.5 ms had 86% specificity and 75% sensitivity in detecting AV block and bundle branch block (AUC = 0.83, 95% CI: 0.664-0.996, p = 0.013). The preprocedure HV distance was 98 +/- 10.55ms in the group with permanent pacemaker implantation and the mean value in the group without permanent pacemaker implantation was 66.27 +/- 15.55 ms, showing a borderline significant difference (p = 0.049).Conclusion: The prolongation of HV interval in patients with AV block and bundle branch block suggests that the block predominantly occurs at the infrahisian level. Patients with longer preprocedural HV intervals should be closely monitored for the need for permanent pacemaker implantation after the TAVR procedure.
引用
收藏
页码:1799 / 1806
页数:10
相关论文
共 50 条
  • [41] Mechanical dispersion is a predictor of 30-day permanent pacemaker implantation after transcatheter aortic valve replacement
    Manshad, A. S.
    Hemu, M.
    Ballout, F. A.
    Zimmerman, A.
    Hein, K. Z.
    Kavinsky, C. J.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3659 - 3659
  • [42] Hemodynamic Impact and Outcome of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Implantation
    Biner, Simon
    Michowitz, Yoav
    Leshem-Rubinow, Eran
    Topilsky, Yan
    Ben-Assa, Eyal
    Shimiaie, Jason
    Banai, Shmuel
    Keren, Gad
    Steinvil, Arie
    Finkelstein, Ariel
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (01): : 132 - 137
  • [43] Conduction disorders in transcatheter aortic valve implantation: which patients for permanent pacemaker implantation?
    Conti, S.
    Pruiti, G. P.
    Tempio, D.
    Romano, S. A.
    Di Grazia, A.
    Ussia, G. P.
    Tamburino, C.
    Calvi, V.
    EUROPEAN HEART JOURNAL, 2012, 33 : 545 - 545
  • [44] Geometry of the aortoventricular annulus as a predictor of pacemaker implantation following transcatheter aortic valve implantation
    Barkagan, M. B.
    Topilsky, Y.
    Steinvil, A.
    Aviram, G.
    Finkelstein, A.
    Banai, S.
    Keren, G.
    Shmilovich, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 1019 - 1019
  • [45] The effect of permanent pacemaker implantation following transcatheter aortic valve implantation upon survival
    Soulaidopoulos, S.
    Drakopoulou, M.
    Stathogiannis, K.
    Xanthopoulou, M.
    Oikonomou, G.
    Toskas, P.
    Kouroutzoglou, A.
    Synetos, A.
    Papanikolaou, A.
    Latsios, G.
    Sideris, S.
    Tousoulis, D.
    Toutouzas, K.
    EUROPEAN HEART JOURNAL, 2020, 41 : 460 - 460
  • [46] Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis
    Jilaihawi, Hasan
    Chin, Derek
    Vasa-Nicotera, Mariuca
    Jeilan, Mohamed
    Spyt, Tomasz
    Ng, G. Andre
    Bence, Johan
    Logtens, Elaine
    Kovac, Jan
    AMERICAN HEART JOURNAL, 2009, 157 (05) : 860 - 866
  • [47] Risk Prediction Model for Permanent Pacemaker Implantation after Transcatheter Aortic Valve Replacement
    Vejpongsa, Pimprapa
    Zhang, Xu
    Bhise, Viraj
    Kitkungvan, Danai
    Shivamurthy, Poojita
    Anderson, H. Vernon
    Balan, Prakash
    Nguyen, Tom C.
    Estrera, Anthony L.
    Dougherty, Anne H.
    Smalling, Richard W.
    Dhoble, Abhijeet
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2018, 2 (04): : 328 - 335
  • [48] Electrocardiographic and further predictors for permanent pacemaker requirements after transcatheter aortic valve implantation
    Nuis, Rutger-Jan
    de Jaegere, Peter
    EUROPACE, 2010, 12 (08): : 1061 - 1062
  • [49] In-Hospital and Readmission Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Megaly, Michael
    Sedhom, Ramy
    Elbadawi, Ayman
    Saad, Marwan
    Cavalcante, Joao
    Sengupta, Jay
    Garcia, Santiago
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B80 - B80
  • [50] Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation
    Erkapic, Damir
    Kim, Won K.
    Weber, Michael
    Moellmann, Helge
    Berkowitsch, Alexander
    Zaltsberg, Sergey
    Pajitnev, Dmitri J.
    Rixe, Johannes
    Neumann, Thomas
    Kuniss, Malte
    Sperzel, Johannes
    Hamm, Christian W.
    Pitschner, Heinz F.
    EUROPACE, 2010, 12 (08): : 1188 - 1190