Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?

被引:0
|
作者
Cetinkaya, Zeki [1 ]
Elcik, Deniz [2 ]
Kelesoglu, Saban [2 ]
Cesur, Burak [3 ]
Yasan, Mustafa [4 ]
Karabiyik, Ugur [5 ]
Bingol, Bilge [6 ]
Kalay, Nihat [2 ]
Topsakal, Ramazan [2 ]
Tuncay, Aydin [7 ]
Dogan, Ali [2 ]
Inanc, Mehmet Tugrul [2 ]
机构
[1] Elazig Fethi Sekin City Hosp, Dept Cardiol, Elazig, Turkiye
[2] Erciyes Univ, Fac Med, Dept Cardiol, Kayseri, Turkiye
[3] Kayseri State Hosp, Dept Cardiol, Kayseri, Turkiye
[4] Kastamonu Training & Res Hosp, Dept Cardiol, Kastamonu, Turkiye
[5] Nigde Training & Res Hosp, Dept Cardiol, Nigde, Turkiye
[6] Kirsehir Training & Res Hosp, Dept Cardiol, Kirsehir, Turkiye
[7] Erciyes Univ, Dept Cardiovasc Surg, Fac Med, Kayseri, Turkiye
关键词
Transcatheter aortic valve implantation; bundle branch block; AV block; atrial-his interval; REPLACEMENT; STENOSIS; BLOCK; PROSTHESIS;
D O I
10.55730/1300-0144.5750
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: Despite advancements in valve technology and increased clinical experience, complications related to conduction defects after transcatheter aortic valve implantation (TAVR) have not improved as rapidly as expected. In this study, we aimed to predict the development of complete atrioventricular (AV) block and bundle branch block during and after the TAVR procedure and to investigate any changes in the cardiac conduction system before and after the procedure using electrophysiological study.Materials and methods: A total of 30 patients who were scheduled for TAVR at our cardiovascular council were planned to be included in the study. TAVR was performed on patients at Erciyes University Medical Faculty Hospital as a single center between May 2019 and August 2020 Diagnostic electrophysiological study was performed before the TAVR procedure and after its completion. Changes in the cardiac conduction system during the preprocedure, intra-procedure, and postprocedure periods were recorded.Results: Significant increases in baseline cycle length, atrial-His (AH) interval, his-ventricular (HV) interval and atrioventricular (AV) distance were observed before and after the TAVR procedure (p = 0.039, p < 0.001, p = 0.018, p < 0.001, respectively). During the TAVR procedure, the preprocedural HV interval was longer in patients who developed AV block and bundle branch block compared to those who did not and this difference was statistically significant (p = 0.024). ROC curve analysis revealed that a TAVR preprocedure HV value >59.5 ms had 86% specificity and 75% sensitivity in detecting AV block and bundle branch block (AUC = 0.83, 95% CI: 0.664-0.996, p = 0.013). The preprocedure HV distance was 98 +/- 10.55ms in the group with permanent pacemaker implantation and the mean value in the group without permanent pacemaker implantation was 66.27 +/- 15.55 ms, showing a borderline significant difference (p = 0.049).Conclusion: The prolongation of HV interval in patients with AV block and bundle branch block suggests that the block predominantly occurs at the infrahisian level. Patients with longer preprocedural HV intervals should be closely monitored for the need for permanent pacemaker implantation after the TAVR procedure.
引用
收藏
页码:1799 / 1806
页数:10
相关论文
共 50 条
  • [31] Incidence and determinants of permanent pacemaker implantation after transcatheter aortic valve replacement
    Bellantoni, Antonio
    Sorrentino, Sabato
    Boccuto, Fabiola
    Carabett, Nicole
    Giordano, Salvatore
    Cacia, Michele Antonio
    Polimeni, Alberto
    Leo, Isabella
    Varano, Ylenia
    Augusto, Florinda Maria
    Mongiardo, Annalisa
    De Rosa, Salvatore
    Indolfi, Ciro
    Spaccarotella, Carmen
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0G) : G196 - G196
  • [32] Quality Control for Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Yazdchi, Farhang
    Hirji, Sameer
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2020, 110 (01): : 347 - 348
  • [33] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Yiming Qi
    Xiaolei Lin
    Wenzhi Pan
    Xiaochun Zhang
    Yuefan Ding
    Shasha Chen
    Lei Zhang
    Daxin Zhou
    Junbo Ge
    European Journal of Medical Research, 28
  • [34] Permanent Pacemaker Implantation after Transcatheter Aortic Valve Replacement - National Experience
    Dhoble, Abhijeet
    Bhise, Viraj
    Balan, Prakash
    Nguyen, Tuyen C.
    Loyalka, Pranav
    Kar, Biswajit
    Smalling, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B293 - B293
  • [35] Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Cost Analysis
    Ahmad, Mansoor
    Patel, Jay N.
    Loc, Brian L.
    Vipparthy, Sharath C.
    Divecha, Chirag
    Barzallo, Pablo X.
    Kim, Minchul
    Baman, Timir
    Barzallo, Marco
    Mungee, Sudhir
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [36] Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement
    Savino, Danielle C.
    McCarthy, Fenton H.
    Spragan, Danielle D.
    Dibble, Taylor
    Graves, Desmond
    Dufendach, Keith
    Giri, Jay S.
    Szeto, Wilson Y.
    Groeneveld, Peter W.
    Herrmann, Howard C.
    Bavaria, Joseph E.
    Desai, Nimesh D.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12) : 1276 - 1278
  • [37] Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation
    Fujita, Buntaro
    Kuetting, Maximilian
    Seiffert, Moritz
    Scholtz, Smita
    Egron, Sandrine
    Prashovikj, Emir
    Boergermann, Jochen
    Schaefer, Timm
    Scholtz, Werner
    Preuss, Rainer
    Gummert, Jan
    Steinseifer, Ulrich
    Ensminger, Stephan M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (12) : 1385 - 1393
  • [38] Influence of permanent pacemaker implantation after transcatheter aortic valve implantation with new-generation devices
    B. Gonska
    M. Keßler
    J. Wöhrle
    W. Rottbauer
    J. Seeger
    Netherlands Heart Journal, 2018, 26 : 620 - 627
  • [39] Impact on late clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve implantation.
    Munoz-Garcia, E.
    Ruiz-Salas, A.
    Munoz-Garcia, M.
    Munoz Garcia, A. J. Antonio Jesus
    Fernandez-Pastor, J.
    Pena, J.
    Dominguez-Franco, A. J.
    Hernandez-Garcia, J. M.
    Alzueta-Rodriguez, J.
    De Teresa-Galvan, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 413 - 413
  • [40] Influence of permanent pacemaker implantation after transcatheter aortic valve implantation with new-generation devices
    Gonska, B.
    Kessler, M.
    Woehrle, J.
    Rottbauer, W.
    Seeger, J.
    NETHERLANDS HEART JOURNAL, 2018, 26 (12) : 620 - 627