Quartz tuning fork-based biosensor for the direct detection of human cytomegalovirus

被引:5
|
作者
Assaifan, Abdulaziz K. [1 ,2 ,3 ]
Al-Gawati, Mahmoud A. [3 ]
Alzahrani, Khalid E. [2 ,3 ,4 ]
Alqahtani, Sultana F. [1 ]
Aldakhil, Shatha M. [1 ]
Alodhayb, Abdullah N. [2 ,3 ,4 ,5 ]
Rahman, Shofiur [3 ]
Albrithen, Hamad [2 ,3 ,4 ,5 ]
机构
[1] King Saud Univ, Coll Appl Med Sci, Dept Biomed Technol, Riyadh 11451, Saudi Arabia
[2] King Salman Ctr Disabil Res, Riyadh, Saudi Arabia
[3] King Saud Univ, King Abdullah Inst Nanotechnol, Biol & Environm Sensing Res Unit, POB 2455, Riyadh 11451, Saudi Arabia
[4] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
[5] King Saud Univ, Coll Sci, Res Chair Tribol Surface & Interface Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
关键词
Quartz tuning fork; Biosensor; Cytomegalovirus; Label; -free; Disability; AMPLIFICATION; INFECTION;
D O I
10.1016/j.jksus.2023.102703
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Human cytomegalovirus (HCMV) possess great threat to immunocompromised patients and pregnant women since It can cause disability if left untreated. Especially for unborn babies, if the virus was not detected at early stages, it can cause disabilities as the baby develops. Furthermore, the virus can be asymptomatic, hence, low-cost and rapid detection techniques are desirable. Currently available detection techniques of the virus are labor intensive and demand experienced technicians. For these reasons, new detection techniques are needed to overcome the current challenges associated with conventional techniques. In this work, quartz tuning fork (QTF)-based biosensor was developed for the detection of UL83-antigen of HCMV for the first time. Firstly, QTF coated with gold was functionalized with cysteamine and glutaraldehyde for UL83-antibody immobilization at the QTF surface. Then, the biosensor was tested against a variety of UL83-antigen concentrations. As the UL83-antigen concentration increased, the measured resonance frequency decreased due to increased mass loading at the QTF surface. The sensitivity of the biosensor is 15.91 Hz/ln(ng/mL). Whereas the limit of detection is 0.36 ng/mL. The biosensor showed comparable biosensing performances to those available in the literature. Furthermore, the biosensor demonstrated its selectivity towards UL83-antigen when tested against samples containing a mixture of biomarkers. The reported work demonstrates a platform for the direct and low-cost mass screening of diseases. & COPY; 2023 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Quartz tuning fork based sensor for detection of volatile organic compounds: towards breath analysis
    Sampson, Abraham
    Panchal, Suresh
    Phadke, Apoorva
    Kashyap, A.
    Suman, Jilma
    Unnikrishnan, G.
    Datar, Suwarna
    MATERIALS RESEARCH EXPRESS, 2018, 5 (04):
  • [42] Adsorption Thermodynamic Analysis of a Quartz Tuning Fork Based Sensor for Volatile Organic Compounds Detection
    Deng, Yue
    Liu, Nai-Yuan
    Tsow, Francis
    Xian, Xiaojun
    Forzani, Erica S.
    ACS SENSORS, 2017, 2 (11): : 1662 - 1668
  • [43] A Z-Axis Quartz Tuning Fork Micromachined Gyroscope Based on Shear Stress Detection
    Wu, Xuezhong
    Xie, Liqiang
    Xing, Jianchun
    Dong, Peitao
    Wang, Haoxu
    Su, Jianbin
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1246 - 1252
  • [44] Development of a fast humidity sensor based on quartz tuning fork
    Carullo, Alessio
    Vallan, Alberto
    Afify, Ahmed S.
    Tulliani, J-M
    2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 285 - 290
  • [45] Direct Detection of Anchor Damping in MEMS Tuning Fork Resonators
    Rodriguez, Janna
    Chandorkar, Saurabh Arun
    Glaze, Grant M.
    Gerrard, Dustin D.
    Chen, Yunhan
    Heinz, David B.
    Flader, Ian B.
    Kenny, Thomas W.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2018, 27 (05) : 800 - 809
  • [46] A comprehensive dual-spectroscopy detection technique based on TDLAS and QEPAS using a quartz tuning fork
    Wang, Zongliang
    Tian, Cunwei
    Qian, Siyu
    Yu, Yuanfang
    Chang, Jun
    Zhang, Qinduan
    Feng, Yiwen
    Li, Hefu
    Feng, Zhenbao
    OPTICS AND LASER TECHNOLOGY, 2022, 145
  • [47] Dynamics of quartz tuning fork force sensors used in standoff photoacoustic detection
    Zhang, Zhouqiang
    Jia, Shuhai
    Ma, Binshan
    Chen, Hualing
    Wei, Yuan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (08) : 3091 - 3096
  • [48] Dynamics of quartz tuning fork force sensors used in standoff photoacoustic detection
    Zhouqiang Zhang
    Shuhai Jia
    Binshan Ma
    Hualing Chen
    Yuan Wei
    Journal of Mechanical Science and Technology, 2015, 29 : 3091 - 3096
  • [49] Metrological scanning probe microscope based on a quartz tuning fork detector
    Babic, Bakir
    Freund, Christopher H.
    Herrmann, Jan
    Lawn, Malcolm A.
    Miles, John
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2012, 11 (01):
  • [50] A metrological Scanning Probe Microscope based on a quartz tuning fork detector
    Babic, Bakir
    Freund, Christopher H.
    Lawn, Malcolm
    Miles, John R.
    Herrmann, Jan
    SCANNING MICROSCOPIES 2011: ADVANCED MICROSCOPY TECHNOLOGIES FOR DEFENSE, HOMELAND SECURITY, FORENSIC, LIFE, ENVIRONMENTAL, AND INDUSTRIAL SCIENCES, 2011, 8036