Managemental Impacts on Particulate Matter Emission in Tunnel-Ventilated Broiler Houses

被引:0
|
作者
Seo, Hyo-Jae [1 ]
Seo, Il-Hwan [1 ]
Oh, Byung-Wook [1 ]
机构
[1] Jeonbuk Natl Univ, Coll Agr & Life Sci, Dept Rural Construct Engn, 567 Baekje Daero, Jeonju 54896, South Korea
来源
AGRICULTURE-BASEL | 2024年 / 14卷 / 02期
关键词
aerosol spectrometer; fine dust; occupational exposure; personal exposure; real-time monitoring; working environment; OCCUPATIONAL-EXPOSURE; LIVESTOCK BUILDINGS; POULTRY WORKERS; AIRBORNE DUST; LUNG-FUNCTION; IDENTIFICATION; AEROSOL;
D O I
10.3390/agriculture14020204
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
In livestock houses, particulate matter (PM) is a critical factor not only for disease and odor spread but also for the work environment. In particular, workers are exposed to high concentrations of organic particulate matter and harmful gases while performing their tasks, and, as they age, they become more vulnerable to respiratory diseases. This study analyzed the PM concentrations in commercial broiler houses, focusing on the differences in ventilation rates according to the season and the type of work, categorized into a static work period (SWP) and dynamic work period (DWP). In the regional monitoring using gravimetric methods, the average PM concentrations were found to be within acceptable limits, with TSP at 1042 mu g/m3, PM-10 at 718 mu g/m3, and PM-2.5 at 137 mu g/m3. These values did not exceed the recommended exposure limits for inhalable dust at 2400 mu g/m3 and respirable dust at 160 mu g/m3 in chicken farmers. However, in the personal monitoring using a real-time aerosol spectrometer, it was revealed that the aerosol concentrations during DWP exceeded the standards by up to 214%. Specifically, during DWP, the concentrations were 1.74 times higher for TSP, 1.40 times higher for PM-10, and 1.22 times higher for PM-2.5 compared to SWP. It was observed that during the movement of workers, the physical generation of particles around 10 mu m, such as feed and bedding, occurred due to the movement of chickens, which influenced the aerosol concentration.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Particulate matter and ammonia emission factors for tunnel-ventilated broiler production houses in the Southern US
    Lacey, RE
    Redwine, JS
    Parnell, CB
    [J]. TRANSACTIONS OF THE ASAE, 2003, 46 (04): : 1203 - 1214
  • [2] Ammonia Emissions in Tunnel-Ventilated Broiler Houses
    Lima, K. A. O.
    Moura, D. J.
    Carvalho, T. M. R.
    Bueno, L. G. F.
    Vercellino, R. A.
    [J]. BRAZILIAN JOURNAL OF POULTRY SCIENCE, 2011, 13 (04) : 265 - 270
  • [3] Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas
    Redwine, JS
    Lacey, RE
    Mukhtar, S
    Carey, JB
    [J]. TRANSACTIONS OF THE ASAE, 2002, 45 (04): : 1101 - 1109
  • [4] Fine particle measurements inside and outside tunnel-ventilated broiler houses
    Visser, M. C.
    Fairchild, B.
    Czarick, M.
    Lacy, M.
    Worley, J.
    Thompson, S.
    Kastner, J.
    Ritz, C.
    Naeher, L. P.
    [J]. JOURNAL OF APPLIED POULTRY RESEARCH, 2006, 15 (03): : 394 - 405
  • [5] Comparison of ammonia measurement methods inside and outside tunnel-ventilated broiler houses
    Hale, B. D.
    Fairchild, B.
    Worley, J.
    Harper, L.
    Ritz, C.
    Czarick, M.
    Rathbun, S. L.
    Irvin, E. A.
    Naeher, L. P.
    [J]. JOURNAL OF APPLIED POULTRY RESEARCH, 2010, 19 (03): : 245 - 262
  • [6] EFFECT OF AIR DEFLECTORS ON FAN PERFORMANCE IN TUNNEL-VENTILATED BROILER HOUSES WITH A DROPPED CEILING
    Purswell, J. L.
    Luck, B. D.
    Davis, J. D.
    [J]. APPLIED ENGINEERING IN AGRICULTURE, 2014, 30 (03) : 471 - 475
  • [7] Concentration and particle size distribution of particulate matter inside tunnel-ventilated high-rise layer operation houses
    Wang-Li, Lingjuan
    Cao, Zihan
    Li, Qianfeng
    Liu, Zifei
    Beasley, David B.
    [J]. ATMOSPHERIC ENVIRONMENT, 2013, 66 : 8 - 16
  • [8] Measurement and Numerical Simulation of Air Velocity in a Tunnel-Ventilated Broiler House
    Bustamante, Eliseo
    Garcia-Diego, Fernando-Juan
    Calvet, Salvador
    Torres, Antonio G.
    Hospitaler, Antonio
    [J]. SUSTAINABILITY, 2015, 7 (02): : 2066 - 2085
  • [9] Size-segregated physicochemical properties of inhalable particulate matter in a tunnel-ventilated layer house in China
    Wang, Xiaoshuai
    Dai, Xiaorong
    Wang, Ailun
    Wang-Li, Lingjuan
    Yang, Mengrong
    Xiao, Hang
    He, Yong
    Wang, Kaiying
    [J]. ENVIRONMENTAL RESEARCH, 2022, 204
  • [10] Energy requirements for operating tunnel ventilated broiler houses
    Overhults, DG
    Gates, RS
    [J]. LIVESTOCK ENVIRONMENT V, VOLS I AND II, 1997, : 859 - 865