Ammonia Emissions in Tunnel-Ventilated Broiler Houses

被引:0
|
作者
Lima, K. A. O. [1 ]
Moura, D. J. [1 ]
Carvalho, T. M. R. [1 ]
Bueno, L. G. F. [2 ]
Vercellino, R. A. [1 ]
机构
[1] Univ Estadual Campinas, Agr Engn Sch, BR-13081970 Campinas, SP, Brazil
[2] Univ Estadual Julio de Mesquita Filho, Sch Anim Sci, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Broiler production; gas emissions; ventilation systems; LIVESTOCK BUILDINGS; PARTICULATE MATTER; LITTER; PROTEIN; RATES;
D O I
暂无
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Gas production in broiler houses and their emissions are closely related to the microclimate established inside the house according to air temperature, humidity, and velocity. Therefore, the internal house environment is influenced by building typology and ventilation system. The objective of the present study was to evaluate ammonia emission rates in broiler houses equipped with different ventilation systems (negative or positive pressure) and litter conditions (new or built-up). The environment of six commercial broiler houses was evaluated internal and external NH3 concentrations. Ventilation rates were recorded to estimate ammonia emission rates. The efficiency of circulation and exhaust fans was assessed, and higher ventilation rates were determined in negative-pressure houses due to the higher flow of the fans. Houses with new litter increased ammonia emission rates along the rearing period, indicating the relationship between gas emissions, bird age and ventilation rates, and presented a typical curve of NH3 emission increase. Negative-pressure houses with built-up litter presented higher emission rates during the first rearing week due to the high NH3 concentration during the brooding period, when the ventilation rates required to maintain chick thermal comfort are low. Although the results of the present study indicate an advantage of the positive-pressure systems as to gas emissions, further research is needed reduce gas emissions in broiler houses with negative-pressure systems.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [1] Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas
    Redwine, Jarah S.
    Lacey, Ronald E.
    Mukhtar, Saqib
    Carey, John B.
    [J]. Transactions of the American Society of Agricultural Engineers, 2002, 45 (04): : 1101 - 1109
  • [2] Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas
    Redwine, JS
    Lacey, RE
    Mukhtar, S
    Carey, JB
    [J]. TRANSACTIONS OF THE ASAE, 2002, 45 (04): : 1101 - 1109
  • [3] Comparison of ammonia measurement methods inside and outside tunnel-ventilated broiler houses
    Hale, B. D.
    Fairchild, B.
    Worley, J.
    Harper, L.
    Ritz, C.
    Czarick, M.
    Rathbun, S. L.
    Irvin, E. A.
    Naeher, L. P.
    [J]. JOURNAL OF APPLIED POULTRY RESEARCH, 2010, 19 (03): : 245 - 262
  • [4] Particulate matter and ammonia emission factors for tunnel-ventilated broiler production houses in the Southern US
    Lacey, RE
    Redwine, JS
    Parnell, CB
    [J]. TRANSACTIONS OF THE ASAE, 2003, 46 (04): : 1203 - 1214
  • [5] Managemental Impacts on Particulate Matter Emission in Tunnel-Ventilated Broiler Houses
    Seo, Hyo-Jae
    Seo, Il-Hwan
    Oh, Byung-Wook
    [J]. AGRICULTURE-BASEL, 2024, 14 (02):
  • [6] Fine particle measurements inside and outside tunnel-ventilated broiler houses
    Visser, M. C.
    Fairchild, B.
    Czarick, M.
    Lacy, M.
    Worley, J.
    Thompson, S.
    Kastner, J.
    Ritz, C.
    Naeher, L. P.
    [J]. JOURNAL OF APPLIED POULTRY RESEARCH, 2006, 15 (03): : 394 - 405
  • [7] Effect of air deflectors on fan performance in tunnel-ventilated broiler houses with a dropped ceiling
    [J]. Purswell, J.L. (joseph.purswell@ars.usda.gov), 1600, American Society of Agricultural and Biological Engineers (30):
  • [8] EFFECT OF AIR DEFLECTORS ON FAN PERFORMANCE IN TUNNEL-VENTILATED BROILER HOUSES WITH A DROPPED CEILING
    Purswell, J. L.
    Luck, B. D.
    Davis, J. D.
    [J]. APPLIED ENGINEERING IN AGRICULTURE, 2014, 30 (03) : 471 - 475
  • [9] Odour emissions from tunnel-ventilated broiler sheds: case study of nine Queensland farms
    Dunlop, Mark
    Gallagher, Erin
    Sohn, Jae Ho
    [J]. ANIMAL PRODUCTION SCIENCE, 2010, 50 (5-6): : 546 - 551
  • [10] Dust emissions from a tunnel-ventilated broiler poultry shed with fresh and partially reused litter
    Modini, Robin L.
    Agranovski, Victoria
    Meyer, N. K.
    Gallagher, Erin
    Dunlop, Mark
    Ristovski, Zoran D.
    [J]. ANIMAL PRODUCTION SCIENCE, 2010, 50 (5-6) : 552 - 556