New algorithm for estimating parameters from interrupted thermal response tests of ground heat exchangers

被引:2
|
作者
Li, Min [1 ,2 ,4 ]
Tan, Yu [1 ]
Wu, Youjian [1 ]
Wang, Qiwei [3 ]
Li, Yong [3 ]
机构
[1] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Hunan, Peoples R China
[2] Cent South Univ, Hunan Prov Key Lab Bioinformat, Changsha 410083, Hunan, Peoples R China
[3] PLA Army Univ Engn, Inst Mil Environm Teaching & Res, Nanjing 210007, Jiangsu, Peoples R China
[4] Cent South Univ, Sch Energy Sci & Engn, Energy Bldg, Changsha 410083, Hunan, Peoples R China
关键词
Ground heat exchangers; Interrupted thermal response tests; Parameter estimation; Tikhonov regularization; Temperature derivative; Short-time G function; BOREHOLE; TIME; UNCERTAINTY; SOIL;
D O I
10.1016/j.applthermaleng.2023.122088
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is a long-standing challenge to determine soil thermal properties from interrupted thermal response tests (TRTs). To meet this challenge, this study develops a new parameter estimation algorithm by integrating three key elements: a short-time model, a derivative-enhanced objective function, and the zero-order Tikhonov regularization strategy. The algorithm is validated to be reliable by a reference sandbox dataset. Whereas interruption reduces the test duration and the number of available test data, it also increases the independence of sensitivity coefficients, thus resulting in high identifiability. To achieve this identifiability, a reliable short-time temperature response model is the prerequisite. Whereas temperature derivatives can boost the temperature data as a set of independent experimental data, regularization is highly necessary to stabilize the iterative solution process by suppressing the influence of the data noise amplified by the temperature derivatives.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Computational methods for ground thermal response of multiple borehole heat exchangers: A review
    Zhang, Changxing
    Wang, Yusheng
    Liu, Yufeng
    Kong, Xiangqiang
    Wang, Qing
    RENEWABLE ENERGY, 2018, 127 : 461 - 473
  • [22] Numerical modeling of ground thermal response with borehole heat exchangers connected in parallel
    Monzo, Patricia
    Puttige, Anjan Rao
    Acuna, Jose
    Mogensen, Palne
    Cazorla, Antonio
    Rodriguez, Juan
    Montagud, Carla
    Cerdeira, Fernando
    ENERGY AND BUILDINGS, 2018, 172 : 371 - 384
  • [23] RECOVERY TIMES AFTER THERMAL RESPONSE TESTS ON VERTICAL BOREHOLE HEAT EXCHANGERS
    Javed, S.
    Claesson, J.
    Ra, Beier
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2034 - +
  • [24] Distributed thermal response tests on pipe-in-pipe borehole heat exchangers
    Acuna, Jose
    Palm, Bjorn
    APPLIED ENERGY, 2013, 109 : 312 - 320
  • [25] Use of temperature derivative to analyze thermal response tests on borehole heat exchangers
    Beier, Richard A.
    APPLIED THERMAL ENGINEERING, 2018, 134 : 298 - 309
  • [26] Method of Averaging the Effective Thermal Conductivity Based on Thermal Response Tests of Borehole Heat Exchangers
    Sapinska-Sliwa, Aneta
    Sliwa, Tomasz
    Twardowski, Kazimierz
    Szymski, Krzysztof
    Gonet, Andrzej
    Zuk, Pawel
    ENERGIES, 2020, 13 (14)
  • [27] Prediction of ground thermal diffusivity from thermal response tests
    Yoon, Seok
    Kim, Min Jun
    ENERGY AND BUILDINGS, 2019, 185 : 239 - 246
  • [28] Estimating Uncertainty of the Design Length of Borehole Ground Heat Exchangers
    Mikhaylova, Olga
    Johnston, Ian W.
    Narsilio, Guillermo A.
    FROM FUNDAMENTALS TO APPLICATIONS IN GEOTECHNICS, 2015, : 688 - 695
  • [29] Stepwise algorithm and new analytical model for estimating multi-parameter of energy piles from thermal response tests
    Zeng, Shu
    Yan, Zhenguo
    Yang, Jun
    ENERGY AND BUILDINGS, 2022, 256
  • [30] On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat Exchangers
    Badenes, Borja
    Mateo Pla, Miguel Angel
    Lemus-Zuniga, Lenin G.
    Saiz Mauleon, Begon
    Urchueguia, Javier F.
    ENERGIES, 2017, 10 (09):