Numerical analysis of the internal biased flow mechanism of the siphon outlet pipe under the action of axial flow pump

被引:2
|
作者
Yang, Fan [1 ,2 ]
Sun, Shengjie [1 ]
Jin, Xiaoyu [1 ]
Li, Sihai [3 ]
Xu, Xudong [4 ]
Jin, Yan [1 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Jiangyang Middle Rd 131, Yangzhou 225009, Peoples R China
[2] Hydrodynam Engn Lab Jiangsu Prov, Yangzhou, Peoples R China
[3] Inst Water Machinery & Municipal Res, Key Lab Jinan Digital Twins & Intelligent Water Co, Jinan, Peoples R China
[4] Water Resources Res Inst Jiangsu Prov, Inst Mat Sturcture, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Axial flow pump; biased flow; energy conversion; numerical simulation; siphon outlet pipe; PRESSURE PULSATION;
D O I
10.1177/09576509231198906
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the often employed flow structures in vertical pumping stations is the siphon outlet pipe. It has a complicated geometric structure and internal flow field, which directly affects how effectively, safely, and steadily pumping stations operate. The entire flow conduit of the vertical axial flow pump device was adopted as the study object in order to elucidate the mechanism of the internal biased flow of the siphon outlet pipe caused by the axial flow pump under different flow conditions, and the three-dimensional unsteady flow field of the vertical axial flow pump device was numerically solved using the numerical simulation technique. Physical model tests were used to confirm the results of the numerical simulation. The findings demonstrate that there is a horizontal bias in the flow of the inlet surface and outlet surface of the elbow pipe of the siphon outlet pipe, and that when the flow rate rises, the degree of the horizontal bias in the flow gradually diminishes, and the ratio of biased flow gradually decreases. The flow in hump segment presents up-and-down flow, and when the flow rate increases, the ratios of biased flow first rises before falling. The major causes of the production of biased flow in the outlet pipe are residual velocity circulation at the guide vane's outlet, wall constraint at the elbow pipe, and flow inertia; Under various flow conditions, the morphologies of the vortex structures in the outlet pipe vary; the characteristics of the energy conversion of each part of the pump device are disclosed, with the inlet pipe having the lowest proportion of energy conversion. Under the optimal flow condition, the elbow-inlet pipe's proportion of energy conversion is only around 1.04%, and the proportions of the guide vane, 60 & DEG; elbow pipe, and siphon outlet pipe's energy conversion are significant and fluctuate with time. The proportion of energy conversion in the elbow-inlet pipe and siphon outlet pipe steadily increases as flow rate rises, but the proportion in the guide vane and 60 & DEG; elbow pipe drops initially before increasing.
引用
收藏
页码:58 / 72
页数:15
相关论文
共 50 条
  • [41] Numerical analysis of pressure pulsation in vertical submersible axial flow pump device under bidirectional operation
    Yang, Fan
    Chang, Pengcheng
    Li, Chao
    Shen, Qiangru
    Qian, Jun
    Li, Jindong
    AIP ADVANCES, 2022, 12 (02)
  • [42] Research on internal cavitation flow in axial flow pump focusing on the energy dissipation under varied operating conditions
    Jia, Xiaoqi
    Zhong, Shaosen
    Miao, Hongjiang
    Ren, Qile
    Liu, Guangbing
    Li, Xiaoqin
    Lin, Zhe
    Zhang, Shuaikang
    Zhu, Zuchao
    PHYSICS OF FLUIDS, 2025, 37 (03)
  • [43] PIV Experimental Study of the Axial Flow Blood Pump's Internal Flow Field Under Pulsatile Condition
    Wang Shuai
    Tan Jianping
    Yu Zheqin
    Xiao Zhiyong
    Wu Weiqiang
    Cheng Lizhi
    4TH INTERNATIONAL CONFERENCE ON APPLIED MATERIALS AND MANUFACTURING TECHNOLOGY, 2018, 423
  • [44] Analysis of Energy Characteristics and Internal Flow Field of "S" Shaped Airfoil Bidirectional Axial Flow Pump
    Xie, Chuanliu
    Feng, Andong
    Fu, Tenglong
    Zhang, Cheng
    Zhang, Tao
    Yang, Fan
    WATER, 2022, 14 (18)
  • [45] Simulation of Internal Flow Characteristics of an Axial Flow Pump with Variable Tip Clearance
    Shen, Jiantao
    Xu, Fengyang
    Cheng, Li
    Pan, Weifeng
    Ge, Yi
    Li, Jiaxu
    Zhang, Jiali
    WATER, 2022, 14 (10)
  • [46] Numerical analysis of internal-flow on two kinds of axial volutes
    College of Energy and Power Eng., Huazhong Univ. of Sci. and Technol., Wuhan 430074, China
    Huazhong Ligong Daxue Xuebao, 2006, 6 (96-98):
  • [47] Numerical and Experimental Investigation on Axial-flow Pump
    Zhang, DeSheng
    Shi, WeiDong
    Chen, Bin
    Guan, XingFan
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 7, 2009, : 76 - 83
  • [48] ANALYSIS OF COMMON AXIAL-FLOW PUMP UNDER REVERSE OPERATION
    Ma, Pengfei
    Wang, Jun
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1B: SYMPOSIA, 2014,
  • [49] Numerical simulation of the performance of tandem axial flow pump
    Wang, Guoyu
    Chen, Rongxin
    Yu, Zhiyi
    Liu, Shuyan
    Zhang, Zhimin
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (12): : 39 - 45
  • [50] Numerical Simulation of Internal Flow Field in a Mixed-flow Pump
    Zhou Hongbin
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON INFORMATIONIZATION, AUTOMATION AND ELECTRIFICATION IN AGRICULTURE, 2008, : 295 - 298