Numerical analysis of the internal biased flow mechanism of the siphon outlet pipe under the action of axial flow pump

被引:2
|
作者
Yang, Fan [1 ,2 ]
Sun, Shengjie [1 ]
Jin, Xiaoyu [1 ]
Li, Sihai [3 ]
Xu, Xudong [4 ]
Jin, Yan [1 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Jiangyang Middle Rd 131, Yangzhou 225009, Peoples R China
[2] Hydrodynam Engn Lab Jiangsu Prov, Yangzhou, Peoples R China
[3] Inst Water Machinery & Municipal Res, Key Lab Jinan Digital Twins & Intelligent Water Co, Jinan, Peoples R China
[4] Water Resources Res Inst Jiangsu Prov, Inst Mat Sturcture, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Axial flow pump; biased flow; energy conversion; numerical simulation; siphon outlet pipe; PRESSURE PULSATION;
D O I
10.1177/09576509231198906
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the often employed flow structures in vertical pumping stations is the siphon outlet pipe. It has a complicated geometric structure and internal flow field, which directly affects how effectively, safely, and steadily pumping stations operate. The entire flow conduit of the vertical axial flow pump device was adopted as the study object in order to elucidate the mechanism of the internal biased flow of the siphon outlet pipe caused by the axial flow pump under different flow conditions, and the three-dimensional unsteady flow field of the vertical axial flow pump device was numerically solved using the numerical simulation technique. Physical model tests were used to confirm the results of the numerical simulation. The findings demonstrate that there is a horizontal bias in the flow of the inlet surface and outlet surface of the elbow pipe of the siphon outlet pipe, and that when the flow rate rises, the degree of the horizontal bias in the flow gradually diminishes, and the ratio of biased flow gradually decreases. The flow in hump segment presents up-and-down flow, and when the flow rate increases, the ratios of biased flow first rises before falling. The major causes of the production of biased flow in the outlet pipe are residual velocity circulation at the guide vane's outlet, wall constraint at the elbow pipe, and flow inertia; Under various flow conditions, the morphologies of the vortex structures in the outlet pipe vary; the characteristics of the energy conversion of each part of the pump device are disclosed, with the inlet pipe having the lowest proportion of energy conversion. Under the optimal flow condition, the elbow-inlet pipe's proportion of energy conversion is only around 1.04%, and the proportions of the guide vane, 60 & DEG; elbow pipe, and siphon outlet pipe's energy conversion are significant and fluctuate with time. The proportion of energy conversion in the elbow-inlet pipe and siphon outlet pipe steadily increases as flow rate rises, but the proportion in the guide vane and 60 & DEG; elbow pipe drops initially before increasing.
引用
收藏
页码:58 / 72
页数:15
相关论文
共 50 条
  • [31] Numerical analysis of vortex and cavitation dynamics of an axial-flow pump
    Gong, Jie
    Luo, Wan-zhen
    Wu, Tie-cheng
    Zhang, Zhi-yuan
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2022, 16 (01) : 1921 - 1938
  • [32] Numerical calculation of cavitating flow in impeller of axial-flow pump
    Yang M.
    Ji K.
    Li Z.
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2010, 41 (SUPPL. 1): : 10 - 14
  • [33] Computer-aided design and numerical flow analysis of axial-flow pump with inducer
    Li, Yaojun
    Wang, Fujun
    Proceedings of the 8th Biennial Conference on Engineering Systems Design and Analysis, Vol 2, 2006, : 717 - 722
  • [34] Numerical simulation and experimental study on flow field in an axial flow pump
    Huang, Huan-Ming
    Gao, Hong
    Du, Zhao-Hui
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2009, 43 (01): : 124 - 128
  • [35] Evolution mechanism of internal flow in the hump region and hump optimization of axial-flow reactor coolant pump
    Chen, Huazheng
    Liu, Xiangsong
    Lu, Yonggang
    Fu, Qiang
    Zhu, Rongsheng
    Li, Huairui
    Su, Haonan
    ENERGY, 2024, 311
  • [36] Numerical study on the mechanism of fluid energy transfer in an axial flow pump impeller under the rotating coordinate system
    Guo, Yanlei
    Yang, Congxin
    Mo, Yingxiang
    Wang, Yan
    Lv, Tianzhi
    Zhao, Sen
    FRONTIERS IN ENERGY RESEARCH, 2023, 10
  • [37] Investigation of internal flow pattern of a multiphase axial pump
    Sano, T.
    Wakai, T.
    Reclari, M.
    Xu, Y.
    Cao, S. L.
    29TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2019, 240
  • [38] Internal Flow and Axial Thrust Balancing of a Rocket Pump
    Shimura, Takashi
    Kawasaki, Satoshi
    Uchiumi, Masaharu
    Kimura, Toshiya
    Matsui, Jun
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (04):
  • [39] Siphon outlet conduit on full passage cavitation characteristics of axial-flow pumping unit
    Zhou D.
    Liu M.
    Chen H.
    2017, Huazhong University of Science and Technology (45): : 128 - 132
  • [40] Experimental and numerical analysis of hydraulic performance in an axial-flow pump under diverse inflow conditions
    Wang, Dongsheng
    Mu, Tong
    Feng, Jiangang
    Zhang, Rui
    Fei, Zhaodan
    Xu, Hui
    Zhang, Peipei
    PHYSICS OF FLUIDS, 2025, 37 (01)