Numerical analysis of the internal biased flow mechanism of the siphon outlet pipe under the action of axial flow pump

被引:2
|
作者
Yang, Fan [1 ,2 ]
Sun, Shengjie [1 ]
Jin, Xiaoyu [1 ]
Li, Sihai [3 ]
Xu, Xudong [4 ]
Jin, Yan [1 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Jiangyang Middle Rd 131, Yangzhou 225009, Peoples R China
[2] Hydrodynam Engn Lab Jiangsu Prov, Yangzhou, Peoples R China
[3] Inst Water Machinery & Municipal Res, Key Lab Jinan Digital Twins & Intelligent Water Co, Jinan, Peoples R China
[4] Water Resources Res Inst Jiangsu Prov, Inst Mat Sturcture, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Axial flow pump; biased flow; energy conversion; numerical simulation; siphon outlet pipe; PRESSURE PULSATION;
D O I
10.1177/09576509231198906
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the often employed flow structures in vertical pumping stations is the siphon outlet pipe. It has a complicated geometric structure and internal flow field, which directly affects how effectively, safely, and steadily pumping stations operate. The entire flow conduit of the vertical axial flow pump device was adopted as the study object in order to elucidate the mechanism of the internal biased flow of the siphon outlet pipe caused by the axial flow pump under different flow conditions, and the three-dimensional unsteady flow field of the vertical axial flow pump device was numerically solved using the numerical simulation technique. Physical model tests were used to confirm the results of the numerical simulation. The findings demonstrate that there is a horizontal bias in the flow of the inlet surface and outlet surface of the elbow pipe of the siphon outlet pipe, and that when the flow rate rises, the degree of the horizontal bias in the flow gradually diminishes, and the ratio of biased flow gradually decreases. The flow in hump segment presents up-and-down flow, and when the flow rate increases, the ratios of biased flow first rises before falling. The major causes of the production of biased flow in the outlet pipe are residual velocity circulation at the guide vane's outlet, wall constraint at the elbow pipe, and flow inertia; Under various flow conditions, the morphologies of the vortex structures in the outlet pipe vary; the characteristics of the energy conversion of each part of the pump device are disclosed, with the inlet pipe having the lowest proportion of energy conversion. Under the optimal flow condition, the elbow-inlet pipe's proportion of energy conversion is only around 1.04%, and the proportions of the guide vane, 60 & DEG; elbow pipe, and siphon outlet pipe's energy conversion are significant and fluctuate with time. The proportion of energy conversion in the elbow-inlet pipe and siphon outlet pipe steadily increases as flow rate rises, but the proportion in the guide vane and 60 & DEG; elbow pipe drops initially before increasing.
引用
收藏
页码:58 / 72
页数:15
相关论文
共 50 条
  • [1] Numerical and Experimental Analysis of Flow and Pulsation in Hump Section of Siphon Outlet Conduit of Axial Flow Pump Device
    Yang, Fan
    Zhang, Yiqi
    Yuan, Yao
    Liu, Chao
    Li, Zhongbin
    Nasr, Ahmed
    APPLIED SCIENCES-BASEL, 2021, 11 (11):
  • [2] Influence of spiral flow on the hydraulic performance of a siphon outlet conduit in an axial flow pump system
    Xu, Lei
    Karney, Bryan
    Shi, Wei
    Ji, Dongtao
    Xu, Bo
    Lu, Weigang
    JOURNAL OF HYDRAULIC RESEARCH, 2022, 60 (04) : 515 - 526
  • [3] Numerical Analysis of Unsteady Internal Flow Characteristics in a Bidirectional Axial Flow Pump
    Dai, Yurui
    Shi, Weidong
    Yang, Yongfei
    Xie, Zhanshan
    Zhang, Qinghong
    SUSTAINABILITY, 2024, 16 (01)
  • [4] Numerical investigation of internal flow mechanisms of siphon outlet passage in pumping system
    Yang, Fan
    Liu, Chao
    Sun, Dandan
    Xie, Rongsheng
    Zhang, Liping
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (06): : 60 - 65
  • [5] Numerical study on the internal flow characteristics of an axial-flow pump under stall conditions
    Kan, Kan
    Zheng, Yuan
    Chen, Yujie
    Xie, Zhanshan
    Yang, Guang
    Yang, Chunxia
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (10) : 4683 - 4695
  • [6] Numerical study on the internal flow characteristics of an axial-flow pump under stall conditions
    Kan Kan
    Yuan Zheng
    Yujie Chen
    Zhanshan Xie
    Guang Yang
    Chunxia Yang
    Journal of Mechanical Science and Technology, 2018, 32 : 4683 - 4695
  • [7] Experimental study and numerical simulation of internal flow dissipation mechanism of an axial-flow pump under different design parameters
    Shi, Lijian
    Han, Yi
    Xu, Pengfei
    Sun, Yi
    Qiao, Fengquan
    Chen, Yiyu
    Xue, Muzi
    Chai, Yao
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Numerical Simulation of Internal Flow in a Contra-rotating Axial Flow Pump
    Momosaki, S.
    Usami, S.
    Watanabe, S.
    Furukawa, A.
    25TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2010, 12
  • [9] Internal Flow Mechanism of Axial-Flow Pump with Adjustable Guide Vanes
    Zhu Honggeng
    Zhang Rentian
    Xi Bin
    Hu Dapeng
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2013, VOL 1A: SYMPOSIA, 2014,
  • [10] Investigation into the Influence of Division Pier on the Internal Flow and Pulsation in the Outlet Conduit of an Axial-Flow Pump
    Yang, Fan
    Jiang, Dongjin
    Wang, Tieli
    Chang, Pengcheng
    Liu, Chao
    Liu, Dongsheng
    APPLIED SCIENCES-BASEL, 2021, 11 (15):