Matrix-assisted laser desorption/ionization mass spectrometry imaging sample preparation using wet-interface matrix deposition for lipid analysis

被引:2
|
作者
Mielczarek, Przemyslaw [1 ]
Suder, Piotr [2 ]
Kret, Paulina [2 ]
Slowik, Tymoteusz [3 ]
Gibula-Tarlowska, Ewa [4 ]
Kotlinska, Jolanta Helena [4 ]
Kotsan, Igor [2 ,5 ]
Bodzon-Kulakowska, Anna [2 ,6 ]
机构
[1] Polish Acad Sci, Maj Inst Pharmacol, Lab Prote & Mass Spectrometry, Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Analyt Chem & Biochem, Krakow, Poland
[3] Med Univ Lublin, Expt Med Ctr, Lublin, Poland
[4] Med Univ Lublin, Med Univ, Dept Pharmacol & Pharmacodynam, Lublin, Poland
[5] Lesya Ukrainka Eastern European Natl Univ, Lutsk, Ukraine
[6] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Analyt Chem & Biochem, A Mickiewicza 30 Ave, PL-30059 Krakow, Poland
关键词
SMALL-MOLECULE METABOLITES; MALDI-MS; PHOSPHOLIPIDS; SECTIONS;
D O I
10.1002/rcm.9531
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleSample preparation is one of the most crucial steps for matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Scientists beginning their study with this technique may be overwhelmed by the variety of matrices, solvents, and concentrations; the methods of their applications; and the lack of widely available knowledge of the effect of these parameters on the results. Here we present in depth the aspects of matrix deposition, which will be helpful for the scientific community. MethodsIn this study, we tested several MALDI matrices, such as 2,5-dihydroxybenzoic acid (DHB), norharmane, N-(1-naphthyl)ethylenediamine dihydrochloride (NEDC), and 9-aminoacridine (9AA), using the SunCollect system: wet-interface matrix deposition in the context of lipid analysis. We optimized the number of matrix layers and nozzle settings in terms of spectral intensity and the overall quality of the obtained ion maps. ResultsOur research presents the effect of the number of matrix layers and nozzle settings on the results and allows for choosing the optimal parameters for the analyses. In positive ionization mode, DHB matrix could be chosen first. In the negative ionization mode, 1,5-diaminonaphthalene matrix produces a higher peak intensity in a lower mass range and seems to provide more information than 9AA. We recommend NEDC for particular processes such as glucose analysis. Compared to the remaining matrices, norharmane shows significant changes in the obtained ion maps. ConclusionsSuch a large amount of data allow us to observe an interesting conclusion: the obtained ion image for a particular ion could differ dramatically with a change in the matrix, the solvent composition, or even the number of matrix layers. This must be considered when interpreting the result, impelling us to compare the results obtained with different matrices with caution.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Matrix-assisted laser desorption ionization mass spectrometry: An overview
    Limbach, PA
    SPECTROSCOPY, 1998, 13 (10) : 16 - +
  • [32] Genesis of matrix-assisted laser desorption ionization mass spectrometry
    Busch, KL
    SPECTROSCOPY, 1999, 14 (04) : 20 - +
  • [33] Preparation of Hard Palm Seeds for Matrix-Assisted Laser Desorption/Ionization-Imaging Mass Spectrometry Analysis
    Martins, Gabriel R.
    Brum, Felipe L.
    Miranda Carvalho da Silva, Davi Marconi
    Barbosa, Livia C.
    Mohana-Borges, Ronaldo
    da Silva, Ayla Sant'Ana
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (196):
  • [34] Sample preparation for lipid analysis of intra-articular adipose tissue by using matrix-assisted laser desorption/ionization imaging
    Haartmans, Mirella J. J.
    Claes, Britt S. R.
    Emanuel, Kaj S.
    Tuijthof, Gabrielle J. M.
    Heeren, Ron M. A.
    Emans, Pieter J.
    Cillero-Pastor, Berta
    ANALYTICAL BIOCHEMISTRY, 2023, 662
  • [35] Review of Matrix-Assisted Laser Desorption Ionization-Imaging Mass Spectrometry for Lipid Biochemical Histopathology
    Yalcin, Emine B.
    de la Monte, Suzanne M.
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2015, 63 (10) : 762 - 771
  • [36] Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging analysis of biospecimens
    Bokhart, M. T.
    Muddiman, D. C.
    ANALYST, 2016, 141 (18) : 5236 - 5245
  • [37] Matrix-Assisted Laser Desorption-Ionization Imaging Mass Spectrometry for Direct Tissue Analysis
    Pallua, J. D.
    Schaefer, G.
    Bittner, L. K.
    Pezzei, C.
    Huck-Pezzei, V.
    Schoenbichler, S. A.
    Meding, S.
    Rauser, S.
    Walch, A.
    Handler, M.
    Netzer, M.
    Osl, M.
    Seger, M.
    Pfeifer, B.
    Baumgartner, C.
    Lindner, H.
    Kremser, L.
    Sarg, B.
    Klocker, H.
    Bartsch, G.
    Bonn, G. K.
    Huck, C. W.
    LC GC NORTH AMERICA, 2011, : 21 - 28
  • [38] A Review of the Application of Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging in Food Analysis
    Yin, Xiaoyu
    Chen, Qian
    Han, Qi
    Kong, Baohua
    Shipin Kexue/Food Science, 2018, 39 (07): : 298 - 304
  • [39] Mechanisms of energy deposition in infrared matrix-assisted laser desorption/ionization mass spectrometry
    Menzel, C
    Dreisewerd, K
    Berkenkamp, S
    Hillenkamp, F
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 207 (1-2) : 73 - 96
  • [40] A comparative study on methods of optimal sample preparation for the analysis of oligonucleotides by matrix-assisted laser desorption/ionization mass spectrometry
    Ragas, JA
    Simmons, TA
    Limbach, PA
    ANALYST, 2000, 125 (04) : 575 - 581