共 50 条
Matrix-assisted laser desorption/ionization mass spectrometry imaging sample preparation using wet-interface matrix deposition for lipid analysis
被引:2
|作者:
Mielczarek, Przemyslaw
[1
]
Suder, Piotr
[2
]
Kret, Paulina
[2
]
Slowik, Tymoteusz
[3
]
Gibula-Tarlowska, Ewa
[4
]
Kotlinska, Jolanta Helena
[4
]
Kotsan, Igor
[2
,5
]
Bodzon-Kulakowska, Anna
[2
,6
]
机构:
[1] Polish Acad Sci, Maj Inst Pharmacol, Lab Prote & Mass Spectrometry, Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Analyt Chem & Biochem, Krakow, Poland
[3] Med Univ Lublin, Expt Med Ctr, Lublin, Poland
[4] Med Univ Lublin, Med Univ, Dept Pharmacol & Pharmacodynam, Lublin, Poland
[5] Lesya Ukrainka Eastern European Natl Univ, Lutsk, Ukraine
[6] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Analyt Chem & Biochem, A Mickiewicza 30 Ave, PL-30059 Krakow, Poland
关键词:
SMALL-MOLECULE METABOLITES;
MALDI-MS;
PHOSPHOLIPIDS;
SECTIONS;
D O I:
10.1002/rcm.9531
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
RationaleSample preparation is one of the most crucial steps for matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Scientists beginning their study with this technique may be overwhelmed by the variety of matrices, solvents, and concentrations; the methods of their applications; and the lack of widely available knowledge of the effect of these parameters on the results. Here we present in depth the aspects of matrix deposition, which will be helpful for the scientific community. MethodsIn this study, we tested several MALDI matrices, such as 2,5-dihydroxybenzoic acid (DHB), norharmane, N-(1-naphthyl)ethylenediamine dihydrochloride (NEDC), and 9-aminoacridine (9AA), using the SunCollect system: wet-interface matrix deposition in the context of lipid analysis. We optimized the number of matrix layers and nozzle settings in terms of spectral intensity and the overall quality of the obtained ion maps. ResultsOur research presents the effect of the number of matrix layers and nozzle settings on the results and allows for choosing the optimal parameters for the analyses. In positive ionization mode, DHB matrix could be chosen first. In the negative ionization mode, 1,5-diaminonaphthalene matrix produces a higher peak intensity in a lower mass range and seems to provide more information than 9AA. We recommend NEDC for particular processes such as glucose analysis. Compared to the remaining matrices, norharmane shows significant changes in the obtained ion maps. ConclusionsSuch a large amount of data allow us to observe an interesting conclusion: the obtained ion image for a particular ion could differ dramatically with a change in the matrix, the solvent composition, or even the number of matrix layers. This must be considered when interpreting the result, impelling us to compare the results obtained with different matrices with caution.
引用
收藏
页数:10
相关论文