A Novel Method to Determine the Maximum Output of Individual Patients for an Active Transcutaneous Bone Conduction Implant Using Clinical Routine Data

被引:1
|
作者
Ghoncheh, Mohammad [1 ,2 ,4 ]
Busch, Susan [1 ,2 ,3 ]
Lenarz, Thomas [1 ,2 ,3 ]
Maier, Hannes [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, Hannover, Germany
[2] Hannover Med Sch, Inst Audioneurotechnol VIANNA, Hannover, Germany
[3] Hannover Med Sch, Cluster Excellence Hearing4all, Hannover, Germany
[4] Hannover Med Sch, Klin Hals Nasen Ohrenheilkunde, Stadtfelddamm 34, D-30625 Hannover, Germany
来源
EAR AND HEARING | 2024年 / 45卷 / 01期
关键词
Audiometry; Bonebridge; Bone conduction; Maximum output hearing level; Maximum power output; Transcutaneous bone conduction implant; HEARING; SOUND; TRANSMISSION; THRESHOLD; DEVICE;
D O I
10.1097/AUD.0000000000001415
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: The maximum output provided by a bone conduction (BC) device is one of the main factors that determines the success when treating patients with conductive or mixed hearing loss. Different approaches such as sound pressure measurements using a probe microphone in the external auditory canal or a surface microphone on the forehead have been previously introduced to determine the maximum output of active transcutaneous BC devices that are not directly accessible after implantation. Here, we introduce a method to determine the maximum output hearing level (MOHL) of a transcutaneous active BC device using patients' audiometric data.Design: We determined the maximum output in terms of hearing level MOHL (dB HL) of the Bonebridge using the audiometric and direct BC threshold of the patient together with corresponding force levels at hearing threshold and the maximum force output of the device. Seventy-one patients implanted with the Bonebridge between 2011 and 2020 (average age 45 +/- 19 years ranging from 5 to 84 years) were included in this study. The analyses of MOHLs were performed by (1) dividing patients into two groups with better or worse average audiometric BC threshold (0.5, 1, 2, 4 kHz), on the ipsilateral side or (2) by separating the MOHLs based on better or worse frequency-by-frequency specific audiometric BC thresholds on the ipsilateral (implanted) side.Results: When using a frequency-by-frequency analysis obtained average ipsilateral MOHLs were in the range between 51 and 73 dB HL for frequencies from 0.5 to 6 kHz in the group with better audiometric BC threshold on the ipsilateral ears. The average contralateral MOHLs in the group with better contralateral hearing were in the range from 43 to 67 dB HL. The variability of the data was approximately 6 to 11 dB (SDs) across measured frequencies (0.5 to 6 kHz). The average MOHLs were 4 to 8 dB higher across frequencies in the group with better audiometric BC threshold on the ipsilateral ears than in the group with better audiometric BC threshold on the contralateral ears. The differences between groups were significant across measured frequencies (t test; p < 0.05).Conclusions: Our proposed method demonstrates that the individual frequency-specific MOHL on the ipsilateral and contralateral side of individual patients with a transcutaneous BC device can be determined mainly using direct and audiometric BC threshold data of the patients from clinical routine. The average MOHL of the implant was found 4 to 8 dB higher on the ipsilateral (implanted) side than on the contralateral side.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 27 条
  • [21] Analysis and Design of RF Power and Data Link Using Amplitude Modulation of Class-E for a Novel Bone Conduction Implant
    Taghavi, Hamidreza
    Hakansson, Bo
    Reinfeldt, Sabine
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (11) : 3050 - 3059
  • [22] Long-Term Stability, Survival, and Tolerability of a Novel Osseointegrated Implant for Bone Conduction Hearing: 3-Year Data From a Multicenter, Randomized, Controlled, Clinical Investigation
    Nelissen, Rik C.
    Stalfors, Joacim
    de Wolf, Maarten J. F.
    Flynn, Mark C.
    Wigren, Stina
    Eeg-Olofsson, Mans
    Green, Kevin
    Rothera, Kmichael P.
    Mylanus, Emmanuel A. M.
    Hol, Myrthe K. S.
    OTOLOGY & NEUROTOLOGY, 2014, 35 (08) : 1486 - 1491
  • [23] A novel method predicting clinical response using only background clinical data in RA patients before treatment with infliximab
    Miyoshi, Fumihiko
    Honne, Kyoko
    Minota, Seiji
    Okada, Masato
    Ogawa, Noriyoshi
    Mimura, Toshihide
    MODERN RHEUMATOLOGY, 2016, 26 (06) : 813 - 816
  • [24] A Novel Method Predicting Good Response Using Only Background Clinical Data In RA Patients Treated With Infliximab
    Miyoshi, Fumihiko
    Honne, Kyoko
    Minota, Seiji
    Okada, Masato
    Ogawa, Noriyoshi
    Mimura, Toshihide
    ARTHRITIS AND RHEUMATISM, 2013, 65 : S627 - S628
  • [25] VALIDATION OF A NOVEL METHOD FOR NONINVASIVE ESTIMATION OF CARDIAC OUTPUT USING BRACHIAL OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS IN PATIENTS WITH VARIOUS CLINICAL CONDITIONS
    Madrid-Munoz, Camilo
    Alvarez-Montoya, Diego
    Fernandez-Ruiz, Ricardo
    Gallo-Villegas, Jaime
    Aristizabal-Ocampo, Dagnovar
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [26] A Novel Type of Dental Tube Implant for Areas with Limited Bone Height. Clinical and Radiographic Data from Three Patients with 5-Year Follow-Up
    Lundgren, Dan
    Slotte, Christer
    Grondahl, Kerstin
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (04) : 509 - 516
  • [27] HD-PATIENTS WITH ATRIAL FIBRILLATION TREATED ADEQUATELY AND SAFE WITH DOAC BY INDIVIDUAL DOSING USING ROUTINE ANTI-XA DRUG-EFFECT MONITORING: LONG-TERM CLINICAL PRACTICE DATA
    Brensing, Karl August
    Raab, Peter
    Heidkamp, Peter
    Poege, Uwe
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2021, 36 : 415 - 415