Long-Term Stability, Survival, and Tolerability of a Novel Osseointegrated Implant for Bone Conduction Hearing: 3-Year Data From a Multicenter, Randomized, Controlled, Clinical Investigation

被引:0
|
作者
Nelissen, Rik C. [1 ]
Stalfors, Joacim [2 ]
de Wolf, Maarten J. F. [1 ]
Flynn, Mark C. [3 ]
Wigren, Stina [3 ]
Eeg-Olofsson, Mans [2 ,4 ]
Green, Kevin
Rothera, Kmichael P. [5 ]
Mylanus, Emmanuel A. M. [1 ]
Hol, Myrthe K. S. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, Dept Otorhinolaryngol, NL-6500 HB Nijmegen, Netherlands
[2] Sahlgrens Univ Hosp, Dept Otorhinolaryngol, Gothenburg, Sweden
[3] Cochlear Bone Anchored Solut AB, Molnlycke, Sweden
[4] Manchester Royal Infirm, Manchester M13 9WL, Lancs, England
[5] Salford Royal Hosp, Salford, Lancs, England
关键词
Bone-Anchored Hearing Aid; Bone-anchored hearing system; Bone conduction; Implant stability quotient; Moderately rough surface; Osseointegration; Resonance frequency analysis; Skin reaction; Wide implant; RESONANCE FREQUENCY-ANALYSIS; BAHA IMPLANT; AIDS; DEVICES;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare the 3-year stability, survival, and tolerability of 2 osseointegrated implants for bone conduction hearing: a wide 4.5-mm-diameter moderately roughened implant with a rounded 6-mm abutment (test) and a 3.75-mm diameter as-machined implant with a conically shaped 5.5-mm abutment (control). Study Design: In this randomized, prospective, controlled, multi-center clinical study, 77 adult patients were included. Test and control implants were randomly assigned in proportions of 2:1. The implants were loaded with the sound processor from 6 weeks postimplantation. Follow-up after surgery was conducted at 10 days; at 4, 6, 8, and 12 weeks; and at 6, 12, 24, and 36 months after surgery. At every visit, implant stability quotient (ISQ) values were recorded by means of resonance frequency analysis (RFA), and skin reactions were evaluated according to Holgers' classification. Results: Statistically significantly higher mean ISQ values were recorded for the test implant compared with the control implant at each evaluation time point. Between 2 and 3 years after surgery, ISQ values decreased but remained above baseline values. Implant survival was high for both implants: 96.2% of the test implants and 100% of the control implants survived these 3 years. Statistically significantly improved soft tissue outcomes were observed in the test implant group. Conclusion: This extensive long-term clinical investigation demonstrated that the test implant is more stable in terms of ISQ-values and provides high tolerability for the soft tissue. The results show that implant loading at 6 weeks is safe.
引用
收藏
页码:1486 / 1491
页数:6
相关论文
共 50 条
  • [1] Stability, Survival, and Tolerability of an Auditory Osseointegrated Implant for Bone Conduction Hearing: Long-Term Follow-Up of a Randomized Controlled Trial
    den Besten, Christine A.
    Stalfors, Joacim
    Wigren, Stina
    Blechert, Johan Ivarsson
    Flynn, Mark
    Eeg-Olofsson, Mans
    Aggarwal, Rohini
    Green, Kevin
    Nelissen, Rik C.
    Mylanus, Emmanuel A. M.
    Hol, Myrthe K. S.
    OTOLOGY & NEUROTOLOGY, 2016, 37 (08) : 1077 - 1083
  • [2] Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
    Rik C. Nelissen
    Christine A. den Besten
    Hubert T. Faber
    Catharina A. J. Dun
    Emmanuel A. M. Mylanus
    Myrthe K. S. Hol
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 1731 - 1737
  • [3] Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability
    Nelissen, Rik C.
    den Besten, Christine A.
    Faber, Hubert T.
    Dun, Catharina A. J.
    Mylanus, Emmanuel A. M.
    Hol, Myrthe K. S.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (07) : 1731 - 1737
  • [4] Stability, Survival, and Tolerability of a Novel Baha Implant System: Six-Month Data From a Multicenter Clinical Investigation
    Dun, Catharina A. J.
    de Wolf, Maarten J. F.
    Hol, Myrthe K. S.
    Wigren, Stina
    Eeg-Olofsson, Mans
    Green, Kevin
    Karlsmo, Anneli
    Flynn, Mark C.
    Stalfors, Joacim
    Rothera, Mike
    Mylanus, Emmanuel A. M.
    Cremers, Cor W. R. J.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (06) : 1001 - 1007
  • [5] Results of a 2-Year Prospective Multicenter Study Evaluating Long-term Audiological and Clinical Outcomes of a Transcutaneous Implant for Bone Conduction Hearing
    Kruyt, Ivo J.
    Monksfield, Peter
    Skarzynski, Piotr H.
    Green, Kevin
    Runge, Christina
    Bosman, Arjan
    Blechert, Johan I.
    Wigren, Stina
    Mylanus, Emmanuel A. M.
    Hol, Myrthe K. S.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (07) : 901 - 911
  • [6] Stability, survival, and tolerability of a 4.5-mm-wide bone-anchored hearing implant: 6-month data from a randomized controlled clinical trial
    Rik C. Nelissen
    Christine A. den Besten
    Emmanuel A. M. Mylanus
    Myrthe K. S. Hol
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 105 - 111
  • [7] Clinical Performance of a New Magnetic Bone Conduction Hearing Implant System: Results From a Prospective, Multicenter, Clinical Investigation
    Briggs, Robert
    Van Hasselt, Andrew
    Luntz, Michal
    Goycoolea, Marcos
    Wigren, Stina
    Weber, Peter
    Smeds, Henrik
    Flynn, Mark
    Cowan, Robert
    OTOLOGY & NEUROTOLOGY, 2015, 36 (05) : 834 - 841
  • [8] Long-Term Follow-up of a Wide-Diameter Bone-Anchored Hearing Implant: 10-Year Experience on Stability, Survival, and Tolerability of an Implant-Abutment Combination
    Teunissen, Emma Margaretha
    Caspers, Coosje Jacoba Isabella
    Vijverberg, Maarten Adriaan
    Mylanus, Emmanuel Antonius Maria
    Hol, Myrthe Karianne Sophie
    OTOLOGY & NEUROTOLOGY, 2023, 44 (01) : 40 - 46
  • [9] Long-term efficacy and tolerability of lanthanum carbonate:: Results from a 3-year study
    Hutchison, AJ
    Maes, B
    Vanwalleghem, J
    Asmus, G
    Mohamed, E
    Schmieder, R
    Backs, W
    Jamar, R
    Vosskühler, A
    NEPHRON CLINICAL PRACTICE, 2006, 102 (02): : 61 - 71
  • [10] Fluocinolone Acetonide Intravitreal Implant for Diabetic Macular Edema: A 3-Year Multicenter, Randomized, Controlled Clinical Trial
    Pearson, P. Andrew
    Comstock, Timothy L.
    Ip, Michael
    Callanan, David
    Morse, Lawrence S.
    Ashton, Paul
    Levy, Brian
    Mann, Eric S.
    Eliott, Dean
    OPHTHALMOLOGY, 2011, 118 (08) : 1580 - 1587