Radiomics based automated quality assessment for T2W prostate MR images

被引:1
|
作者
Thijssen, Linda C. P. [1 ,2 ]
de Rooij, Maarten [1 ]
Barentsz, Jelle O. [1 ]
Huisman, Henkjan J. [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Nijmegen, Netherlands
[2] Radboud Univ Nijmegen Med Ctr, Dept Imaging, Geert Grootepl Zuid 10, NL-6525 GA Nijmegen, Netherlands
关键词
Prostatic neoplasms; Multiparametric magnetic resonance imaging; Artificial Intelligence; Proof of concept study; Quality assurance; Health care; IMAGING QUALITY; SYSTEM;
D O I
10.1016/j.ejrad.2023.110928
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The guidelines for prostate cancer recommend the use of MRI in the prostate cancer pathway. Due to the variability in prostate MR image quality, the reliability of this technique in the detection of prostate cancer is highly variable in clinical practice. This leads to the need for an objective and automated assessment of image quality to ensure an adequate acquisition and hereby to improve the reliability of MRI. The aim of this study is to investigate the feasibility of Blind/referenceless image spatial quality evaluator (Brisque) and radiomics in automated image quality assessment of T2-weighted (T2W) images.Method: Anonymized axial T2W images from 140 patients were scored for quality using a five-point Likert scale (low, suboptimal, acceptable, good, very good quality) in consensus by two readers. Images were dichotomized into clinically acceptable (very good, good and acceptable quality images) and clinically unacceptable (low and suboptimal quality images) in order to train and verify the model. Radiomics and Brisque features were extracted from a central cuboid volume including the prostate. A reduced feature set was used to fit a Linear Discriminant Analysis (LDA) model to predict image quality. Two hundred times repeated 5-fold cross-validation was used to train the model and test performance by assessing the classification accuracy, the discrimination accuracy as receiver operating curve - area under curve (ROC-AUC), and by generating confusion matrices. Results: Thirty-four images were classified as clinically unacceptable and 106 were classified as clinically acceptable. The accuracy of the independent test set (mean & PLUSMN; standard deviation) was 85.4 & PLUSMN; 5.5%. The ROCAUC was 0.856 (0.851 - 0.861) (mean; 95% confidence interval).Conclusions: Radiomics AI can automatically detect a significant portion of T2W images of suboptimal image quality. This can help improve image quality at the time of acquisition, thus reducing repeat scans and improving diagnostic accuracy.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Evaluation of unenhanced axial T1W and T2W liver MR images acquired from institutions within the Republic of Ireland and the Kingdom of Saudi Arabia
    Al-Dahery, S.
    McGee, A.
    Rainford, L.
    Khashoggi, K.
    Misha, N.
    [J]. RADIOGRAPHY, 2019, 25 (02) : E45 - E51
  • [32] Gd-DTPA增强的T1W与T2W MR尿路成像对比
    G.Staatz
    C.C.A.Nolte-Ernsting
    P.Haage
    张可
    [J]. 放射学实践, 2002, (05) : 430 - 430
  • [33] MULTI-PLANAR T2W MRI FOR AN IMPROVED PROSTATE CANCER LESION CLASSIFICATION
    Fernandez-Quilez, Alvaro
    Eftestol, Trygve
    Kjosavik, Svein Reidar
    Goodwin, Morten
    Oppedal, Ketil
    [J]. 2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [34] A two-step automated quality assessment for liver MR images based on convolutional neural network
    Wang, Yida
    Song, Yang
    Wang, Fang
    Sun, Jingjing
    Gao, Xinyi
    Han, Zhe
    Shi, Lei
    Shao, Guoliang
    Fan, Mingxia
    Yang, Guang
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [35] Automated Quality Assessment of Cardiac MR Images Using Convolutional Neural Networks
    Zhang, Le
    Gooya, Ali
    Dong, Bo
    Hua, Rui
    Petersen, Steffen E.
    Medrano-Gracia, Pau
    Frangi, Alejandro F.
    [J]. SIMULATION AND SYNTHESIS IN MEDICAL IMAGING, SASHIMI 2016, 2016, 9968 : 138 - 145
  • [36] Thinking Beyond Adenocarcinoma of Prostate: A Case Series of T2W Hyperintense Prostatic Lesions
    Swarna
    Sharma, Rohit
    Jain, Shalabh
    Sharma, Anuradha
    Kanaujia, Reeta
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (09) : TR1 - TR4
  • [37] Can T1w/T2w ratio be used as a myelin-specific measure in subcortical structures? Comparisons between FSE-based T1w/T2w ratios, GRASE-based T1w/T2w ratios and multi-echo GRASE-based myelin water fractions
    Uddin, Md Nasir
    Figley, Teresa D.
    Marrie, Ruth Ann
    Figley, Chase R.
    [J]. NMR IN BIOMEDICINE, 2018, 31 (03)
  • [38] Shearlet Transform Applied to a Prostate Cancer Radiomics Analysis on MR Images
    Corso, Rosario
    Stefano, Alessandro
    Salvaggio, Giuseppe
    Comelli, Albert
    [J]. MATHEMATICS, 2024, 12 (09)
  • [39] Automated reference tissue normalization of T2-weighted MR images of the prostate using object recognition
    Mohammed R. S. Sunoqrot
    Gabriel A. Nketiah
    Kirsten M. Selnæs
    Tone F. Bathen
    Mattijs Elschot
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 309 - 321
  • [40] Automated reference tissue normalization of T2-weighted MR images of the prostate using object recognition
    Sunoqrot, Mohammed R. S.
    Nketiah, Gabriel A.
    Selnaes, Kirsten M.
    Bathen, Tone F.
    Elschot, Mattijs
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (02) : 309 - 321