Radiomics based automated quality assessment for T2W prostate MR images

被引:1
|
作者
Thijssen, Linda C. P. [1 ,2 ]
de Rooij, Maarten [1 ]
Barentsz, Jelle O. [1 ]
Huisman, Henkjan J. [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Nijmegen, Netherlands
[2] Radboud Univ Nijmegen Med Ctr, Dept Imaging, Geert Grootepl Zuid 10, NL-6525 GA Nijmegen, Netherlands
关键词
Prostatic neoplasms; Multiparametric magnetic resonance imaging; Artificial Intelligence; Proof of concept study; Quality assurance; Health care; IMAGING QUALITY; SYSTEM;
D O I
10.1016/j.ejrad.2023.110928
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The guidelines for prostate cancer recommend the use of MRI in the prostate cancer pathway. Due to the variability in prostate MR image quality, the reliability of this technique in the detection of prostate cancer is highly variable in clinical practice. This leads to the need for an objective and automated assessment of image quality to ensure an adequate acquisition and hereby to improve the reliability of MRI. The aim of this study is to investigate the feasibility of Blind/referenceless image spatial quality evaluator (Brisque) and radiomics in automated image quality assessment of T2-weighted (T2W) images.Method: Anonymized axial T2W images from 140 patients were scored for quality using a five-point Likert scale (low, suboptimal, acceptable, good, very good quality) in consensus by two readers. Images were dichotomized into clinically acceptable (very good, good and acceptable quality images) and clinically unacceptable (low and suboptimal quality images) in order to train and verify the model. Radiomics and Brisque features were extracted from a central cuboid volume including the prostate. A reduced feature set was used to fit a Linear Discriminant Analysis (LDA) model to predict image quality. Two hundred times repeated 5-fold cross-validation was used to train the model and test performance by assessing the classification accuracy, the discrimination accuracy as receiver operating curve - area under curve (ROC-AUC), and by generating confusion matrices. Results: Thirty-four images were classified as clinically unacceptable and 106 were classified as clinically acceptable. The accuracy of the independent test set (mean & PLUSMN; standard deviation) was 85.4 & PLUSMN; 5.5%. The ROCAUC was 0.856 (0.851 - 0.861) (mean; 95% confidence interval).Conclusions: Radiomics AI can automatically detect a significant portion of T2W images of suboptimal image quality. This can help improve image quality at the time of acquisition, thus reducing repeat scans and improving diagnostic accuracy.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Deep learning based correction of RF field induced inhomogeneities for T2w prostate imaging at 7 T
    Harrevelt, Seb D.
    Meliado, Ettore F. M.
    van Lier, Astrid L. H. M. W.
    Reesink, Daan
    Meijer, Richard P.
    Pluim, Josien P. W.
    Raaijmakers, Alexander J. E.
    [J]. NMR IN BIOMEDICINE, 2023,
  • [22] Deep learning based correction of RF field induced inhomogeneities for T2w prostate imaging at 7 T
    Harrevelt, Seb D.
    Meliado, Ettore F. M.
    van Lier, Astrid L. H. M. W.
    Reesink, Daan
    Meijer, Richard P.
    Pluim, Josien P. W.
    Raaijmakers, Alexander J. E.
    [J]. NMR IN BIOMEDICINE, 2023, 36 (12)
  • [23] Registration and image quality of T2w 3D TSE scans of the Unity MR-linac
    Van Pelt, V.
    Janssen, T.
    Walraven, I.
    Liskamp, C.
    Lambregts, D.
    Van der Heide, U.
    Nowee, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S271 - S271
  • [24] Prediction of prostate cancer recurrence after radiotherapy using a fused machine learning approach: utilizing radiomics from pretreatment T2W MRI images with clinical and pathological information
    Nanekaran, Negin Piran
    Felefly, Tony H.
    Schieda, Nicola
    Morgan, Scott C.
    Mittal, Richa
    Ukwatta, Eranga
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (06):
  • [25] Texture-based classification of different single liver lesion based on SPAIR T2W MRI images
    Li, Zhenjiang
    Mao, Yu
    Huang, Wei
    Li, Hongsheng
    Zhu, Jian
    Li, Wanhu
    Li, Baosheng
    [J]. BMC MEDICAL IMAGING, 2017, 17
  • [26] Texture-based classification of different single liver lesion based on SPAIR T2W MRI images
    Zhenjiang Li
    Yu Mao
    Wei Huang
    Hongsheng Li
    Jian Zhu
    Wanhu Li
    Baosheng Li
    [J]. BMC Medical Imaging, 17
  • [27] Fully automated quality control of rigid and affine registrations of T1w and T2w MRI in big data using machine learning
    Tummala, Sudhakar
    Thadikemalla, Venkata Sainath Gupta
    Kreilkamp, Barbara A. K.
    Dam, Erik B.
    Focke, Niels K.
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 139
  • [28] Evaluation of Deep Neural Networks for Semantic Segmentation of Prostate in T2W MRI
    Khan, Zia
    Yahya, Norashikin
    Alsaih, Khaled
    Ali, Syed Saad Azhar
    Meriaudeau, Fabrice
    [J]. SENSORS, 2020, 20 (11) : 1 - 17
  • [29] 3D-Vision-Transformer Stacking Ensemble for Assessing Prostate Cancer Aggressiveness from T2w Images
    Pachetti, Eva
    Colantonio, Sara
    [J]. BIOENGINEERING-BASEL, 2023, 10 (09):
  • [30] Evaluation of T2W FLAIR MR image quality using artificial intelligence image reconstruction techniques in the pediatric brain
    Nagaraj, Usha D.
    Dillman, Jonathan R.
    Tkach, Jean A.
    Greer, Joshua S.
    Leach, James L.
    [J]. PEDIATRIC RADIOLOGY, 2024, 54 (08) : 1337 - 1343