A comparison of two techniques of internal jugular vein cannulation: Landmark-guided technique versus ultrasound-guided technique

被引:0
|
作者
Davis, Josemine [1 ,6 ]
Dwivedi, Deepak [2 ]
Sawhney, Sadhan [3 ]
Rai, Amit [1 ]
Dua, Amit [4 ]
Singh, Satyen Kumar [5 ]
机构
[1] Command Hosp Western Command, Dept Anaesthesiol & Crit Care, Chandigarh, India
[2] Command Hosp Eastern Command, Dept Anaesthesiol & Crit Care, Kolkata, India
[3] Command Hosp Southern Command, Dept Anaesthesiol & Crit Care, Pune, India
[4] Army Hosp R&R, Dept Anaesthesiol & Crit Care, New Delhi, India
[5] Base Hosp, Dept Anaesthesiol & Crit Care, Lucknow, India
[6] Command Hosp Western Command Chandimandir, Dept Anaesthesiol & Crit Care, Panchkula, Haryana, India
关键词
Cannulation; central venous catheterization; jugular vein; landmark; ultrasonography; CENTRAL VENOUS CANNULATION; COMPLICATIONS; CATHETERIZATION; PLACEMENT; INSERTION; ARTERIAL; GUIDANCE; RATES;
D O I
10.4103/jmms.jmms_13_22
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: This study was designed to compare the overall success rates and complications of two techniques of internal jugular vein (IJV) catheterization, namely the landmark (LM)-based technique and ultrasound (US)-guided technique in a heterogeneous Indian population at an Armed Forces Tertiary Care Hospital. Methods: Ninety consenting patients were assigned to two groups: LM and US groups. Patients with known coagulation abnormalities, body mass index > 30, infection at the insertion site, known vascular abnormalities, burn contractures, and other dermatologic conditions that precluded an LM technique were excluded. Central venous catheterizations during the code blue scenarios were excluded due to the emergent nature of the procedure. Three operators from the author group with requisite experience in LM and US techniques performed the 90 catheterizations. In LM group, a finder needle with a 2 ml syringe was used to aspirate venous blood from the IJV. A 16G needle was guided in the same direction as the finder needle till venous blood was aspirated, followed by guidewire insertion and cannulation. In the US group, a 6-12 MHz linear US probe was used to identify the IJV in real time and a 16G needle was used to access the IJV under US guidance in the cross-sectional view. Results: The overall success rate was 84.4% in LM group and 100% in US group (P = 0.0059). The first attempt success rate was similar in both groups (71.1% and 86.6%, P = 0.07). The overall complication rates in LM group were 20%, whereas complications in the US group were 2.2% (P = 0.0073). Notably, vascular complications occurred less frequently in US group with fewer arterial punctures and hematomas. Hemothorax and pneumothorax did not occur in any group. The mean cannulation time decreased by 69 s, i.e., from 276 s in the LM group to 207 s in the US group (P < 0.001). Conclusion: US-guided central venous catheter insertion to IJV improves the overall success rate and reduces cannulation time as compared to conventional LM-based technique.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [41] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    WANG Yao
    WANG Gang
    GAO Chang-qing
    中华医学杂志(英文版), 2013, 126 (13) : 2414 - 2417
  • [42] Absence of the Right Internal Jugular Vein During Ultrasound-Guided Cannulation
    Alagoz, Ali
    Tunc, Mehtap
    Sazak, Hilal
    Pehlivanoglu, Polat
    Gokcek, Atila
    Ulus, Fatma
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (03) : 212 - 214
  • [43] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    Wang Yao
    Wang Gang
    Gao Chang-qing
    CHINESE MEDICAL JOURNAL, 2013, 126 (13) : 2414 - 2417
  • [44] Neonatologist-Performed Ultrasound-Guided Internal Jugular Vein Cannulation
    Anup Thakur
    Manoj Modi
    Neelam Kler
    Pankaj Garg
    Indian Pediatrics, 2023, 60 : 72 - 74
  • [45] Needle and guidewire visualization in ultrasound-guided internal jugular vein cannulation
    Moak, James H.
    Lyons, Michael S.
    Wright, Stewart W.
    Lindsell, Christopher J.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (04): : 432 - 436
  • [46] Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Praveen Maheshwari
    Parul Maheshwari
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 362 - 363
  • [47] Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients
    Dimitrios Karakitsos
    Nicolaos Labropoulos
    Eric De Groot
    Alexandros P Patrianakos
    Gregorios Kouraklis
    John Poularas
    George Samonis
    Dimosthenis A Tsoutsos
    Manousos M Konstadoulakis
    Andreas Karabinis
    Critical Care, 10
  • [48] Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Maheshwari, Praveen
    Maheshwari, Parul
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2016, 63 (03): : 362 - 363
  • [49] Eal-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients
    Karakitsos, Dimitrios
    Labropoulos, Nicolaos
    De Groot, Eric
    Patrianakos, Alexandros P.
    Kouraklis, Gregorios
    Poularas, John
    Samonis, George
    Tsoutsos, Dimosthenis A.
    Konstadoulakis, Manousos M.
    Karabinis, Andreas
    CRITICAL CARE, 2006, 10 (06):
  • [50] Comparison between long- and short-axis techniques for ultrasound-guided cannulation of internal jugular vein
    Shrestha, Gentle Sunder
    Gurung, Arjun
    Koirala, Sabin
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (02) : 288 - 292