Microfluidic device using metallic nanostructure arrays for the isolation, detection, and purification of exosomes

被引:5
|
作者
Hsiao, Yu-Sheng [1 ]
Chen, Chun-Wei [1 ]
Haliq, Ridhwan [1 ]
Yiu, Pak-Man [2 ]
Wu, Po-I. [1 ]
Chu, Jinn P. [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mat Sci & Engn, Taipei 106335, Taiwan
[2] Ming Chi Univ Technol, Dept Mat Engn, New Taipei City 243303, Taiwan
关键词
Microfluidic; Metallic nanostructure arrays (MeNTAs); Exosome; Liquid biopsy; CAPTURE; RELEASE;
D O I
10.1016/j.jallcom.2023.169658
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Microfluidic devices are widely used in disease detection and specimen separation due to their low cost, rapid processing, and the ability to use even minuscule samples. This study reports on the embedding of metallic nanostructure arrays (MeNTAs) with tube-like features in microfluidic devices for the im-munoaffinity-based detection and efficient isolation of exosomes. We assessed MeNTA candidates in terms of their ability to withstand the mechanical stress of microfluidic operations (indentation analysis) as well as X-ray diffraction, zeta potential, and electrostatic interactions involving antibody coatings. Note that Zr60Cu25Al10Ni5 thin film metallic glass (Zr-TFMG) features outstanding mechanical properties and a ne-gative zeta potential exceeding those of other common materials (e.g., Cu, Bronze, Ag, 7075Al, Ti64, 718Ni, SS316, Cu-TFMG, W-TFMG, and Al-TFMG). The resulting microfluidic device featured Zr-based MeNTAs with an interdigital electrode embedded in a microchannel. When applied to MCF-7 derived exosomes using a liquid biopsy of only 500 mu L, the proposed device (similar to 6.25 million nanostructures/cm2) achieved an exosome recovery rate of 95.3% within 1 h, while resisting nonspecific binding to HeLa-derived exosomes (recovery rate of < 0.1%). The device enabled the isolation of 1 x 108 exosome particles per mL-1 for detection via electrochemical impedance spectroscopy. It also enabled the efficient release of captured exosomes via cyclic voltammetry (CV) operations over a potential range of -0.8 to +0.8 V. The proposed Zr-MeNTA mi-crofluidic device has considerable potential for the isolation, detection, and purification of exosomes in liquid biopsy samples for cancer diagnosis.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Bacterial concentration and detection using an ultrasonic nanosieve within a microfluidic device
    Ang, Bryan
    Habibi, Ruhollah
    Kett, Ciaren
    Chin, Wai Hoe
    Tuck, Kellie L.
    Neild, Adrian
    Cadarso, Victor J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 374
  • [32] Peanut Detection Using Droplet Microfluidic Polymerase Chain Reaction Device
    Ma, Shou-Yu
    Chiang, Yu-Cheng
    Hsu, Chia-Hsien
    Chen, Jyh-Jian
    Hsu, Chin-Chi
    Chao, An-Chong
    Lin, Yung-Sheng
    JOURNAL OF SENSORS, 2019, 2019
  • [33] DEBRIS DETECTION IN HYDRAULIC OIL USING A MICROFLUIDIC INDUCTIVE PULSE DEVICE
    Zhang, Hongpeng
    Huang, Wen
    Jin, Junwei
    Guo, Li
    Li, Dongqing
    PROCEEDINGS OF THE ASME MICRO/NANOSCALE HEAT AND MASS TRANSFER INTERNATIONAL CONFERENCE, 2012, 2012, : 51 - 57
  • [34] Real-time detection of neurite outgrowth using microfluidic device
    Kim, Samhwan
    Jang, Jongmoon
    Choi, Hongsoo
    Moon, Cheil
    NANO-BIO SENSING, IMAGING, AND SPECTROSCOPY, 2013, 8879
  • [35] Colorimetric Detection of Extracellular Hydrogen Peroxide Using an Integrated Microfluidic Device
    Dervisevic, Esma
    Voelcker, Nicolas H.
    Risbridger, Gail
    Tuck, Kellie L.
    Cadarso, Victor J.
    ANALYTICAL CHEMISTRY, 2022, 94 (03) : 1726 - 1732
  • [36] Isolation and Detection of Exosomes Using Fe2O3 Nanoparticles
    Farhana, Fatema Zerin
    Umer, Muhammad
    Saeed, Ayad
    Pannu, Amandeep Singh
    Shahbazi, Mahboobeh
    Jabur, Aiden
    Nam, Hyun Jae
    Ostrikov, Kostya
    Sonar, Prashant
    Firoz, Shakhawat H.
    Shiddiky, Muhammad J. A.
    ACS APPLIED NANO MATERIALS, 2021, 4 (02) : 1175 - 1186
  • [37] Microsphere mediated exosome isolation and ultra-sensitive detection on a dielectrophoresis integrated microfluidic device
    Zhao, Wenjie
    Zhang, Lingqian
    Ye, Yifei
    Li, Yuang
    Luan, Xiaofeng
    Liu, Jinlong
    Cheng, Jie
    Zhao, Yang
    Li, Mingxiao
    Huang, Chengjun
    ANALYST, 2021, 146 (19) : 5962 - 5972
  • [38] Simultaneous colorimetric detection of metallic salts contained in low explosives residue using a microfluidic paper-based analytical device (μPAD)
    Chabaud, Kathryn R.
    Thomas, Jennifer L.
    Torres, Michelle N.
    Oliveira, Sheila
    McCord, Bruce R.
    FORENSIC CHEMISTRY, 2018, 9 : 35 - 41
  • [39] Rapid, continuous purification of proteins in a microfluidic device using genetically-engineered partition tags
    Meagher, Robert J.
    Light, Yooli K.
    Singh, Anup K.
    LAB ON A CHIP, 2008, 8 (04) : 527 - 532
  • [40] Purification of microalgae from bacterial contamination using a disposable inertia-based microfluidic device
    Godino, Neus
    Jorde, Felix
    Lawlor, Daryl
    Jaeger, Magnus
    Duschl, Claus
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2015, 25 (08)