Pre-Processing Based ECG Signal Analysis Using Emerging Tools

被引:11
|
作者
Gupta, Varun [1 ]
Sharma, Arvind Kumar [1 ]
Pandey, Pawan Kumar [2 ]
Jaiswal, Ritesh Kumar [3 ]
Gupta, Anshu [4 ]
机构
[1] KIET Grp Inst, Delhi NCR, Dept Elect & Elect Engn, Ghaziabad 201206, Uttar Pradesh, India
[2] GGITS, Dept Elect Engn, Jabalpur 482003, India
[3] JSS Acad Tech Educ, Dept Elect & Commun Engn, Noida 201301, Uttar Pradesh, India
[4] KLPG Coll, Dept Educ, Meerut, Uttar Pradesh, India
关键词
Independent Principal Component Analysis (IPCA); Electrocardiogram (ECG); Fractional Fourier Transform (FrFT); Fractional Wavelet Transform (FrWT); Pre-processing; Motion artefacts; WAVELET TRANSFORM; COMPRESSION; ARTIFACTS; NOISE;
D O I
10.1080/03772063.2023.2202162
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of the paper is to count the clear beats (R-peaks or QRS complexes) in the Electrocardiogram (ECG) signal after pre-processing step. Among the three selected techniques, Independent Principal Component Analysis (IPCA), Fractional Fourier Transform (FrFT) and Fractional Wavelet Transform (FrWT) have Sensitivity (Se) of 99.92%, 99.95% and 99.98%, Accuracy (Acc) of 99.88%, 99.93% and 99.96%, Detection Error Rate (DER) of 0.110%, 0.066% and 0.036% along with the disturbance of 2.3%, 2% and 1.7% respectively. The lowest DER in FrWT indicates that it outperforms the IPCA and FrFT. The False Negative plus False Positive (FN + FP) by using the three techniques was 32, 25 and 13 while the output Signal-to-Noise Ratio (SNR) was found to be 24.42, 26.19 and 34.37 dB respectively. These results were figured out on Real Time Database (RT DB). The values of output SNR, Se and Acc were recorded to be 34.37 dB, 99.98% and 99.96% while using FrWT based pre-processing on the data from RT DB. The same technique when used on the data from MIT-BIH arrhythmia Database (MB DB) gave the values of 24.81 dB, 99.96% and 99.93% respectively. It has been observed that all the attributes of the components of ECG signals were preserved when filtered with FrFT. On the other hand, the FrWT segregates the motion artefacts and ECG signal in a better way than FrFT. This is due to the fact that in FrWT decomposition takes place on the signal rotated at a selected angle resulting in less computationally complex decompositions at various levels. It reveals that FrWT retains important biology-related information as the originally recorded ECG signal has.
引用
收藏
页码:4219 / 4230
页数:12
相关论文
共 50 条
  • [41] Pre-processing using topographic mappings
    Wu, Y
    Fyfe, C
    PROCEEDINGS OF THE 2005 INTERNATIONAL CONFERENCE ON NEURAL NETWORKS AND BRAIN, VOLS 1-3, 2005, : 1881 - 1884
  • [42] Speech enhancement using pre-processing
    Singh, L
    Sridharan, S
    IEEE TENCON'97 - IEEE REGIONAL 10 ANNUAL CONFERENCE, PROCEEDINGS, VOLS 1 AND 2: SPEECH AND IMAGE TECHNOLOGIES FOR COMPUTING AND TELECOMMUNICATIONS, 1997, : 755 - 758
  • [43] Testing the effects of pre-processing on voxel based morphometry analysis
    Chaitanya, C., V
    Koirala, N.
    Mideksa, K. G.
    Anwar, A. R.
    Schmidt, G.
    Deuschl, G.
    Groppa, S.
    Muthuraman, M.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 4302 - 4305
  • [44] A hybrid signal pre-processing approach in processing ultrasonic signals with noise
    Palanisamy, S.
    Nagarajah, C. R.
    Graves, K.
    Iovenitti, P.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 42 (7-8): : 766 - 771
  • [45] Wavelet Transform Based Pre-processing for Side Channel Analysis
    Debande, Nicolas
    Souissi, Youssef
    El Aabid, M. Abdelaziz
    Guilley, Sylvain
    Danger, Jean-Luc
    2012 IEEE/ACM 45TH INTERNATIONAL SYMPOSIUM ON MICROARCHITECTURE WORKSHOPS, 2012, : 32 - 38
  • [46] A hybrid signal pre-processing approach in processing ultrasonic signals with noise
    S. Palanisamy
    C. R. Nagarajah
    K. Graves
    P. Iovenitti
    The International Journal of Advanced Manufacturing Technology, 2009, 42 : 766 - 771
  • [47] EEG energy analysis based on MEMD with ICA pre-processIng
    Yin, Yunchao
    Cao, Jianting
    Tanaka, Toshihisa
    2012 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC), 2012,
  • [48] Set-Based Pre-Processing for Points-To Analysis
    Smaragdakis, Yannis
    Balatsouras, George
    Kastrinis, George
    ACM SIGPLAN NOTICES, 2013, 48 (10) : 253 - 269
  • [49] Pre-Processing techniques and artificial intelligence algorithms for electrocardiogram (ECG) signals analysis: A comprehensive review
    Safdar, Muhammad Farhan
    Nowak, Robert Marek
    Palka, Piotr
    COMPUTERS IN BIOLOGY AND MEDICINE, 2024, 170
  • [50] Convergence analysis of stereophonic echo canceller with pre-processing - Relation between pre-processing and convergence
    Hirano, A
    Nakayama, K
    Watanabe, K
    ICASSP '99: 1999 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, PROCEEDINGS VOLS I-VI, 1999, : 861 - 864