Pre-Processing Based ECG Signal Analysis Using Emerging Tools

被引:11
|
作者
Gupta, Varun [1 ]
Sharma, Arvind Kumar [1 ]
Pandey, Pawan Kumar [2 ]
Jaiswal, Ritesh Kumar [3 ]
Gupta, Anshu [4 ]
机构
[1] KIET Grp Inst, Delhi NCR, Dept Elect & Elect Engn, Ghaziabad 201206, Uttar Pradesh, India
[2] GGITS, Dept Elect Engn, Jabalpur 482003, India
[3] JSS Acad Tech Educ, Dept Elect & Commun Engn, Noida 201301, Uttar Pradesh, India
[4] KLPG Coll, Dept Educ, Meerut, Uttar Pradesh, India
关键词
Independent Principal Component Analysis (IPCA); Electrocardiogram (ECG); Fractional Fourier Transform (FrFT); Fractional Wavelet Transform (FrWT); Pre-processing; Motion artefacts; WAVELET TRANSFORM; COMPRESSION; ARTIFACTS; NOISE;
D O I
10.1080/03772063.2023.2202162
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of the paper is to count the clear beats (R-peaks or QRS complexes) in the Electrocardiogram (ECG) signal after pre-processing step. Among the three selected techniques, Independent Principal Component Analysis (IPCA), Fractional Fourier Transform (FrFT) and Fractional Wavelet Transform (FrWT) have Sensitivity (Se) of 99.92%, 99.95% and 99.98%, Accuracy (Acc) of 99.88%, 99.93% and 99.96%, Detection Error Rate (DER) of 0.110%, 0.066% and 0.036% along with the disturbance of 2.3%, 2% and 1.7% respectively. The lowest DER in FrWT indicates that it outperforms the IPCA and FrFT. The False Negative plus False Positive (FN + FP) by using the three techniques was 32, 25 and 13 while the output Signal-to-Noise Ratio (SNR) was found to be 24.42, 26.19 and 34.37 dB respectively. These results were figured out on Real Time Database (RT DB). The values of output SNR, Se and Acc were recorded to be 34.37 dB, 99.98% and 99.96% while using FrWT based pre-processing on the data from RT DB. The same technique when used on the data from MIT-BIH arrhythmia Database (MB DB) gave the values of 24.81 dB, 99.96% and 99.93% respectively. It has been observed that all the attributes of the components of ECG signals were preserved when filtered with FrFT. On the other hand, the FrWT segregates the motion artefacts and ECG signal in a better way than FrFT. This is due to the fact that in FrWT decomposition takes place on the signal rotated at a selected angle resulting in less computationally complex decompositions at various levels. It reveals that FrWT retains important biology-related information as the originally recorded ECG signal has.
引用
收藏
页码:4219 / 4230
页数:12
相关论文
共 50 条
  • [21] New cepstral methods of signal pre-processing for operational modal analysis
    Randall, R. B.
    Peeters, B.
    Antoni, J.
    Manzato, S.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2012) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2012), 2012, : 755 - 764
  • [22] Pre-processing for segmentation using independent component analysis
    Nakai, T
    Muraki, S
    Isoda, H
    Takehara, Y
    Sakahara, H
    Matsuo, K
    Kato, C
    Miki, Y
    NEUROIMAGE, 2001, 13 (06) : S207 - S207
  • [23] Signal pre-processing using cepstral editing for vibration-based bearing fault detection
    Peeters, C.
    Guillaume, P.
    Helsen, J.
    PROCEEDINGS OF ISMA2016 INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING AND USD2016 INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS, 2016, : 2489 - 2501
  • [24] Signal Processing Algorithm for Pre-processing the Surface Plasmon Resonance Signal Response
    Anshori, Isa
    Solihin, Aminul
    Alrasyid, Muhammad Harun
    Harimurti, Suksmandhira
    Gumilar, Gilang
    Yusuf, Muhammad
    Sari, Silmina Prastriyati
    Yuliarto, Brian
    Arnafia, Wyanda
    2020 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET): FOSTERING INNOVATION THROUGH ICTS FOR SUSTAINABLE SMART SOCIETY, 2020, : 348 - 351
  • [25] Design of pre-processing circuit for wireless ECG monitoring system
    Zhu, Jie
    Rao, Nini
    Liang, Dasong
    Chen, Wei
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 598 - 602
  • [26] Pre-processing ECG signals for smart home material application
    Vidhya, R. Bharathi
    Jerritta, S.
    MATERIALS TODAY-PROCEEDINGS, 2022, 49 : 2955 - 2961
  • [27] Pre-processing deconvolution based technique for improving the performances of ECG codecs: Comparison to SPIHT
    El Khansa, Lina
    Nait-Ali, Amine
    Khalil, Mohamad
    DIGITAL SIGNAL PROCESSING, 2008, 18 (06) : 900 - 906
  • [28] Pre Processing the Abdominal ECG signal using combination of FIR filter and Principal Component Analysis
    Savitha, R., V
    Breesha, S. R.
    Joseph, X. Felix
    2015 INTERNATIONAL CONFERENCED ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2015), 2015,
  • [30] SIGNAL PRE-PROCESSING SUBSYSTEM FOR THE PURPOSE OF INDUSTRIAL CONTROL
    Puchr, Ivan
    Herout, Pavel
    ICINCO 2011: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 1, 2011, : 415 - 418