Development of an improved standard reference material for folate vitamers in human serum

被引:1
|
作者
Camara, Johanna E. [1 ]
Pritchett, Jeanita S. [1 ]
Daniels, Yasmine C. [1 ]
Bedner, Mary [1 ]
Nelson, Michael A. [1 ]
Lowenthal, Mark S. [1 ]
Fazili, Zia [2 ]
Pfeiffer, Christine M. [2 ]
Phinney, Karen W. [1 ]
Sharpless, Katherine E. [1 ]
Sander, Lane C. [1 ]
Lippa, Katrice A. [1 ]
Yen, James H. [1 ]
Kuszak, Adam J. [3 ]
Wise, Stephen A. [3 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Natl Ctr Environm Hlth, Ctr Dis Control & Prevent, Atlanta, GA 30341 USA
[3] NIH, Off Dietary Supplements, Bldg 10, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Folate; Reference material; Human serum; Liquid chromatography-tandem mass spectrometry; TANDEM MASS-SPECTROMETRY; HEALTH; NHANES; FORMS;
D O I
10.1007/s00216-022-04474-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material (R) (SRM (R)) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-mu g folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-alpha-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.
引用
下载
收藏
页码:809 / 821
页数:13
相关论文
共 50 条
  • [41] Development of bovine serum albumin certified reference material
    Liqing Wu
    Bin Yang
    Jiaming Bi
    Jing Wang
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3443 - 3449
  • [42] Development of a standard reference material for Cr(VI) in contaminated soil
    Nagourney, Stuart J.
    Wilson, Stephen A.
    Buckley, Brian
    Kingston, H. M. Skip
    Yang, Shen-Yi
    Long, Stephen E.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (11) : 1550 - 1554
  • [43] Development of a kelp powder (Thallus laminariae) Standard Reference Material
    Lee L. Yu
    Joseph F. Browning
    Carolyn Q. Burdette
    George C. Caceres
    Kaitlyn D. Chieh
    W. Clay Davis
    Brittany L. Kassim
    Stephen E. Long
    Karen E. Murphy
    Rabia Oflaz
    Rick L. Paul
    Katherine E. Sharpless
    Laura J. Wood
    James H. Yen
    Rolf Zeisler
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1265 - 1278
  • [44] Development of a kelp powder (Thallus laminariae) Standard Reference Material
    Yu, Lee L.
    Browning, Joseph F.
    Burdette, Carolyn Q.
    Caceres, George C.
    Chieh, Kaitlyn D.
    Davis, W. Clay
    Kassim, Brittany L.
    Long, Stephen E.
    Murphy, Karen E.
    Oflaz, Rabia
    Paul, Rick L.
    Sharpless, Katherine E.
    Wood, Laura J.
    Yen, James H.
    Zeisler, Rolf
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (04) : 1265 - 1278
  • [45] THE CERTIFICATION OF MORPHINE AND CODEINE IN A HUMAN URINE STANDARD REFERENCE MATERIAL
    TAI, SSC
    CHRISTENSEN, RG
    PAULE, RC
    SANDER, LC
    WELCH, MJ
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (01) : 7 - 12
  • [46] Standard Reference Material 2366 for Measurement of Human Cytomegalovirus DNA
    Haynes, Ross J.
    Kline, Margaret C.
    Toman, Blaza
    Scott, Calum
    Wallace, Paul
    Butler, John M.
    Holden, Marcia J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (02): : 177 - 185
  • [47] THE CERTIFICATION OF COCAINE AND BENZOYLECGONINE IN A HUMAN URINE STANDARD REFERENCE MATERIAL
    ELLERBE, P
    TAI, SSC
    CHRISTENSEN, RG
    ESPINOSALENIZ, R
    PAULE, RC
    SANDER, LC
    SNIEGOSKI, LT
    WELCH, MJ
    WHITE, E
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (03) : 158 - 162
  • [48] Determination of folate vitamers in human serum by stable-isotope-dilution tandem mass spectrometry and comparison with radioassay and microbiologic assay
    Pfeiffer, CM
    Fazili, Z
    McCoy, L
    Zhang, M
    Gunter, EW
    CLINICAL CHEMISTRY, 2004, 50 (02) : 423 - 432
  • [49] Certification of fat soluble vitamins, carotenoids, and cholesterol in human serum: Standard reference material 968b
    Thomas, JBR
    Kline, MC
    Schiller, SB
    Ellerbe, PM
    Sniegoski, LT
    Duewer, DL
    Sharpless, KE
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (01): : 1 - 9
  • [50] Development of NIST Standard Reference Material 2082, a Pathlength Standard for Measurements in the Ultraviolet Spectrum
    Lang, Brian
    Urbas, Aaron
    DeRose, Paul
    Liu, Hung-Kung
    Travis, John
    Choquette, Steve
    Cole, Kenneth D.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2017, 122 : 1 - 14