Development of an improved standard reference material for folate vitamers in human serum

被引:1
|
作者
Camara, Johanna E. [1 ]
Pritchett, Jeanita S. [1 ]
Daniels, Yasmine C. [1 ]
Bedner, Mary [1 ]
Nelson, Michael A. [1 ]
Lowenthal, Mark S. [1 ]
Fazili, Zia [2 ]
Pfeiffer, Christine M. [2 ]
Phinney, Karen W. [1 ]
Sharpless, Katherine E. [1 ]
Sander, Lane C. [1 ]
Lippa, Katrice A. [1 ]
Yen, James H. [1 ]
Kuszak, Adam J. [3 ]
Wise, Stephen A. [3 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Natl Ctr Environm Hlth, Ctr Dis Control & Prevent, Atlanta, GA 30341 USA
[3] NIH, Off Dietary Supplements, Bldg 10, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Folate; Reference material; Human serum; Liquid chromatography-tandem mass spectrometry; TANDEM MASS-SPECTROMETRY; HEALTH; NHANES; FORMS;
D O I
10.1007/s00216-022-04474-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material (R) (SRM (R)) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-mu g folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-alpha-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.
引用
下载
收藏
页码:809 / 821
页数:13
相关论文
共 50 条
  • [31] Development of a southern oceanic air standard reference material
    George C. Rhoderick
    Michael E. Kelley
    Walter R. Miller
    Gordon Brailsford
    Antonio Possolo
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1159 - 1169
  • [32] DEVELOPMENT OF THE NBS BERYLLIUM ISOTOPIC STANDARD REFERENCE MATERIAL
    FASSETT, JD
    INN, KGW
    WATTERS, RL
    RESONANCE IONIZATION SPECTROSCOPY 1988, 1989, 94 : 379 - 382
  • [33] Development of a Cigarette Tobacco Filler Standard Reference Material
    Sander, Lane C.
    Pritchett, Jeanita S.
    Daniels, Yasmine C.
    Wood, Laura J.
    Lang, Brian E.
    Wise, Stephen A.
    Yen, James H.
    Johnson, Tricia L.
    Walters, Matthew J.
    Phillips, Tracy
    Holman, Matthew R.
    Lee, Grace E.
    Lisko, Joseph G.
    Lane, Brian
    Valentin-Blasini, Liza
    Watson, Clifford
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10461 - 10467
  • [34] DEVELOPMENT OF A PROVISIONAL REFERENCE HUMAN CORD SERUM STANDARD FOR ALPHA-FETOPROTEIN DETERMINATION
    GRIFFITHS, BW
    PRINGLE, DN
    GODARD, A
    CLINICAL BIOCHEMISTRY, 1980, 13 (06) : 279 - 284
  • [35] Estimation of the reference interval for serum folate measured with assays traceable to the WHO International Standard
    Ferraro, Simona
    Panzeri, Andrea
    Borille, Simona
    Szoke, Dominika
    Panteghini, Mauro
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (09) : E195 - E196
  • [36] REFERENCE VALUES FOR SERUM FOLATE, ERYTHROCYTE FOLATE AND SERUM COBALAMIN IN NIGERIAN ADOLESCENTS
    OSIFO, BOA
    LUKANMBI, FA
    BOLODEOKU, JO
    TROPICAL AND GEOGRAPHICAL MEDICINE, 1986, 38 (03): : 259 - 264
  • [37] Development of a matrix-based candidate reference material of total homocysteine in human serum
    Liu, Yu
    Song, Dewei
    Xu, Bei
    Li, Hongmei
    Dai, Xinhua
    Chen, Baorong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (13) : 3329 - 3335
  • [38] Development of a matrix-based candidate reference material of total homocysteine in human serum
    Yu Liu
    Dewei Song
    Bei Xu
    Hongmei Li
    Xinhua Dai
    Baorong Chen
    Analytical and Bioanalytical Chemistry, 2017, 409 : 3329 - 3335
  • [39] Development and usage of a NIST standard reference material for real time PCR quantitation of human DNA
    Vallone, P. M.
    Kline, M. C.
    Duewer, D. L.
    Decker, A. E.
    Redman, J. W.
    Travis, J. C.
    Smith, M. V.
    Butler, J. M.
    FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2008, 1 (01) : 80 - 82
  • [40] Determination of folate vitamers in food and in Italian reference diet by high-performance liquid chromatography
    Ruggeri, S
    Vahteristo, LT
    Aguzzi, A
    Finglas, P
    Carnovale, E
    JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) : 237 - 245