Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures

被引:1
|
作者
Fleifel, Dominik [1 ,2 ]
Pytiak, Andrew V. [3 ]
Jin, Xin [4 ]
Cizmic, Zlatan [5 ]
Vaidya, Rahul [1 ,2 ]
机构
[1] Wayne State Univ, Dept Orthopaed Surg, Sch Med, Detroit, MI 48202 USA
[2] Detroit Med Ctr, Dept Orthopaed Surg, Detroit, MI 48201 USA
[3] Rocky Mt Hosp Children, Dept Pediat Orthopaed Surg, Denver, CO USA
[4] Wayne State Univ, Dept Biomed Engn, Sch Med, Detroit, MI USA
[5] St John Providence Hosp, Dept Orthopaed Surg, Southfield, MI USA
关键词
burke plate; fracture; radius; subcutaneous; external fixator; internal fixation; DISTRACTION PLATE; INTERNAL-FIXATION; OPEN REDUCTION; LOCKING PLATE; BRIDGE PLATE; VOLAR; DORSAL; COMPLICATIONS; PINS; COMPRESSION;
D O I
10.7759/cureus.39142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background External fixators that span the wrist have been the historical norm in treating distal radius fractures. We have modified a dorsal distraction approach by using a subcutaneously applied locked bridge plate through two small incisions superficial to the extensor tendons and outside the extensor compartment. The purpose of this study was to biomechanically evaluate this modified method of fixation for comminuted distal radius fractures in comparison with two established constructs. Methods Matched cadaver specimens were used to model an AO Type 23-C3 distal radius fracture. Biochemical testing for stiffness during axial compressive loading was done on three constructs: a conventional Burke distraction plate, the subcutaneous internal fixation plating technique, and an external fixator. All specimens were cyclically loaded for 3000 cycles and then retested. Results The modified construct was found to be stiffer than the external fixator (p=0.013). When compared to the Burke plate, the modified construct was significantly less stiff before axial cycling (p=0.025). However, the difference was not maintained after cycling, and the post-axial loading stiffness difference was nonsignificant (p=0.456). Conclusion Our data demonstrate the biomechanical integrity of the subcutaneous plating technique for the fixation of comminuted distal radius fractures. It is stiffer than an external fixator and has the theoretical advantage of avoiding pin-tract infections. In addition, it is subcutaneous and not a cumbersome external construct. Our construct is minimally invasive, and it does not violate the dorsal extensor compartments. This allows for finger movement even while the construct is in place.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Prospective study of comminuted articular distal radius fractures stabilized by volar plating in the elderly
    Daniel Martinez-Mendez
    Alejandro Lizaur-Utrilla
    Joaquin de Juan-Herrero
    International Orthopaedics, 2018, 42 : 2243 - 2248
  • [42] Dorsal bridge plating versus bridging external fixation for management of complex distal radius fractures
    Mohamed, Mohamed A.
    Abdel-Wanis, Mohamed E.
    Said, Elsayed
    Abdel-Aziz, Islam A.
    Ahmed, Ahmed M.
    Addosooki, Ahmad
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3344 - 3351
  • [43] Open Reduction and Plate Fixation, External Fixator, and Conservative Treatment for Intra- articular Distal Radius Fractures
    Akdemir, Mehmet
    Kilic, Ali Ihsan
    Kurt, Cengizhan
    Capkin, Sercan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [44] Comparison of External Fixation vs Volar Plating for Comminuted Fracture of the Distal End Radius
    Shah, Syed Habib Ullah
    Iqbal, Mazhar
    Muhammad, Eid
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (04): : 1342 - 1343
  • [45] Outcome following plate-osteosynthesis of comminuted intraarticular distal radius fractures
    Lenzlinger, PM
    Stärkle, R
    Büchel, H
    Melcher, GA
    BRITISH JOURNAL OF SURGERY, 2004, 91 (07) : 915 - 916
  • [46] THE RESULTS OF EXTERNAL FIXATION OF THE RADIUS IN THE TREATMENT OF COMMINUTED INTRAARTICULAR FRACTURES OF THE DISTAL END
    BISHAY, M
    AGUILERA, X
    GRANT, J
    DUNKERLEY, DR
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (03): : 378 - 383
  • [47] Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixator
    Tyllianakis, Minos
    Mylonas, Spyros
    Saridis, Alkis
    Kallivokas, Alkiviadis
    Kouzelis, Antonis
    Megas, Panagiotis
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (03): : 306 - 311
  • [48] INTRAARTICULAR FRACTURES OF THE DISTAL PART OF THE RADIUS TREATED WITH THE SMALL AO EXTERNAL FIXATOR
    EDWARDS, GS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (08): : 1241 - 1250
  • [49] Titanium Elastic Nailing with Temporary External Fixator versus Bridge Plating in Comminuted Pediatric Femoral Shaft Fractures: A Comparative Study
    Sukalyan Dey
    Kartikey Mishra
    Tarai Vishanji Nagda
    Jaideep Dhamele
    Chasanal Rathod
    Dipa Dey
    Indian Journal of Orthopaedics, 2018, 52 : 507 - 512
  • [50] THE SMALL AO EXTERNAL FIXATOR FOR FRACTURES OF THE DISTAL RADIUS AND OTHER APPLICATIONS - FOREWORD
    JAKOB, RP
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 25 : SD1 - SD1