Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures

被引:1
|
作者
Fleifel, Dominik [1 ,2 ]
Pytiak, Andrew V. [3 ]
Jin, Xin [4 ]
Cizmic, Zlatan [5 ]
Vaidya, Rahul [1 ,2 ]
机构
[1] Wayne State Univ, Dept Orthopaed Surg, Sch Med, Detroit, MI 48202 USA
[2] Detroit Med Ctr, Dept Orthopaed Surg, Detroit, MI 48201 USA
[3] Rocky Mt Hosp Children, Dept Pediat Orthopaed Surg, Denver, CO USA
[4] Wayne State Univ, Dept Biomed Engn, Sch Med, Detroit, MI USA
[5] St John Providence Hosp, Dept Orthopaed Surg, Southfield, MI USA
关键词
burke plate; fracture; radius; subcutaneous; external fixator; internal fixation; DISTRACTION PLATE; INTERNAL-FIXATION; OPEN REDUCTION; LOCKING PLATE; BRIDGE PLATE; VOLAR; DORSAL; COMPLICATIONS; PINS; COMPRESSION;
D O I
10.7759/cureus.39142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background External fixators that span the wrist have been the historical norm in treating distal radius fractures. We have modified a dorsal distraction approach by using a subcutaneously applied locked bridge plate through two small incisions superficial to the extensor tendons and outside the extensor compartment. The purpose of this study was to biomechanically evaluate this modified method of fixation for comminuted distal radius fractures in comparison with two established constructs. Methods Matched cadaver specimens were used to model an AO Type 23-C3 distal radius fracture. Biochemical testing for stiffness during axial compressive loading was done on three constructs: a conventional Burke distraction plate, the subcutaneous internal fixation plating technique, and an external fixator. All specimens were cyclically loaded for 3000 cycles and then retested. Results The modified construct was found to be stiffer than the external fixator (p=0.013). When compared to the Burke plate, the modified construct was significantly less stiff before axial cycling (p=0.025). However, the difference was not maintained after cycling, and the post-axial loading stiffness difference was nonsignificant (p=0.456). Conclusion Our data demonstrate the biomechanical integrity of the subcutaneous plating technique for the fixation of comminuted distal radius fractures. It is stiffer than an external fixator and has the theoretical advantage of avoiding pin-tract infections. In addition, it is subcutaneous and not a cumbersome external construct. Our construct is minimally invasive, and it does not violate the dorsal extensor compartments. This allows for finger movement even while the construct is in place.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Biomechanics and biology of external fixation of distal radius fractures
    Bindra, RR
    HAND CLINICS, 2005, 21 (03) : 363 - +
  • [22] A new technique for distal forearm fractures:: the external radius fixator
    Kadas, Istvan
    Szita, Janos
    Renner, Antal
    Vendegh, Zsolt
    Gloviczki, Balazs
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2007, 18 (03): : 143 - 149
  • [23] Is the external fixator yet useful for treating fractures of the distal radius?
    Rongières M.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1495 - 1497
  • [24] Locked wires fixator for fractures of the distal third of the radius and ulna in children
    Naito, Kiyohito
    Kawakita, So
    Nagura, Nana
    Sugiyama, Yoichi
    Obata, Hiroyuki
    Goto, Kenji
    Kaneko, Ayaka
    Kaneko, Kazuo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (07): : 1193 - 1197
  • [25] Locked wires fixator for fractures of the distal third of the radius and ulna in children
    Kiyohito Naito
    So Kawakita
    Nana Nagura
    Yoichi Sugiyama
    Hiroyuki Obata
    Kenji Goto
    Ayaka Kaneko
    Kazuo Kaneko
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1193 - 1197
  • [26] Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures
    Mignemi, Megan E.
    Byram, Ian R.
    Wolfe, Carmen C.
    Fan, Kang-Hsien
    Koehler, Elizabeth A.
    Block, John J.
    Jordanov, Martin I.
    Watson, Jeffry T.
    Weikert, Douglas R.
    Lee, Donald H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (01): : 40 - 48
  • [27] Dorsal Locked Plate Fixation of Distal Radius Fractures
    Lutsky, Kevin
    Boyer, Martin
    Goldfarb, Charles
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (07): : 1414 - 1422
  • [28] The use of dorsal distraction plating for severely comminuted distal radius fractures: A review and comparison to volar plate fixation
    Perlus, R.
    Doyon, J.
    Henry, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : S50 - S55
  • [29] Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Gradl, Georg
    Klitscher, Daniela
    Mehling, Isabella
    Mehler, Dorothea
    Mueller, Lars P.
    Rommens, Pol M.
    CLINICAL BIOMECHANICS, 2010, 25 (08) : 771 - 775
  • [30] Distraction Plating for the Treatment of Highly Comminuted Distal Radius Fractures in Elderly Patients
    Richard, Marc J.
    Katolik, Leonid I.
    Hanel, Douglas P.
    Wartinbee, Daniel A.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (05): : 948 - 956