99mTc-methoxyisobutylisonitrile single-photon emission computed tomography/computed tomography parathyroid imaging in the diagnosis of functional parathyroid cysts: an initial experience

被引:1
|
作者
Wei, Yushan [1 ,2 ]
Liu, Yan [1 ]
Yang, Lulu [1 ]
Xu, Hui [1 ]
Yang, Yiyuan [1 ]
Liang, Yiqian [1 ]
Zhang, Yuchen [1 ]
Yang, Aimin [1 ]
Tang, Xiaojiang [3 ]
Xue, Jianjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Nucl Med, Affiliated Hosp 1, 277 West Yanta Rd, Xian, Peoples R China
[2] Xian Chest Hosp, Dept Med Imaging, Xian, Peoples R China
[3] Xi An Jiao Tong Univ, Dept Breast Surg, Affiliated Hosp 1, Xian, Peoples R China
关键词
Parathyroid cyst (PCs); functional parathyroid cysts ( FPCs); single-photon emission computed; tomography/computed tomography imaging (SPECT/CT imaging); 99mTc-methoxyisobutylisonitrile (99mTc-MIBI); hyperparathyroidism (HPT); F-18-FLUOROCHOLINE PET/CT; POSSIBLE PITFALL; HYPERPARATHYROIDISM; LOCALIZATION; SENSITIVITY; ASPIRATION; LESIONS; ENTITY;
D O I
10.21037/gs-23-273
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Functional parathyroid cysts ( FPCs) are rare and difficult to diagnose with noninvasive methods. The aim of this study was to evaluate the diagnostic value of 99mTc-methoxyisobutylisonitrile (99mTcMIBI) single-photon emission computed tomography/computerized tomography (SPECT/CT) parathyroid imaging in the diagnosis of FPCs and to account for its performance. Methods: The data from 10 patients with suspected parathyroid cysts (PCs) who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2012 and 2022 were retrospectively evaluated. The diagnostic value of 99mTc-MIBI SPECT/CT parathyroid imaging for FPCs was analyzed. Results: Surgical resection was performed in six cases and parathyroid puncture was performed in four cases. The sensitivity of 99mTc-MIBI SPECT/CT for FPCs was 100.0% (3/3), with a specificity of 100.0% (7/7) and an accuracy of 100.0% (10/ 10). The postoperative pathological findings in three cases of FPCs were parathyroid adenoma, parathyroid adenoma with hemorrhage, and parathyroid adenoma with cystic degeneration, respectively. The diagnostic accuracy of ultrasound and CT for PCs was only 22.22% (2/9) and 25.0% (1/4), respectively, and neither modality could indicate whether the cysts were functional or not. Conclusions: 99mTc-MIBI parathyroid SPECT/CT imaging has a high value in the diagnosis of FPCs in patients with suspected PCs, and an intense ring-shaped accumulation of radioactivity in the cyst wall on 99mTc-MIBI imaging suggests that the patient may have FPCs.
引用
收藏
页码:32 / 44
页数:13
相关论文
共 50 条
  • [41] RECEPTOR IMAGING BY POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    FROST, JJ
    INVESTIGATIVE RADIOLOGY, 1992, 27 : S54 - S58
  • [42] Radiopharmaceuticals for single-photon emission computed tomography brain imaging
    Kung, HF
    Kung, MP
    Choi, SR
    SEMINARS IN NUCLEAR MEDICINE, 2003, 33 (01) : 2 - 13
  • [43] Single-photon emission computed tomography/computed tomography: Basic instrumentation and innovations
    O'Connor, Michael K.
    Kemp, Brad J.
    SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (04) : 258 - 266
  • [44] Comparative imaging of ectopic mediastinal parathyroid adenoma with magnetic resonance imaging and single photon emission computed tomography/computed tomography: advantages of multimodality imaging
    Liu, Xiangxiang
    Meng, Zhaowei
    Wang, Peng
    Jia, Qiang
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2020, 35 (04): : 1024 - 1025
  • [45] Accuracy of early-phase versus dual-phase single-photon emission computed tomography/computed tomography in the localization of Parathyroid disease
    Mandal, Rajarsi
    Muthukrishnan, Ashok
    Ferris, Robert L.
    de Almeida, John R.
    Duvvuri, Umamaheswar
    LARYNGOSCOPE, 2015, 125 (06): : 1496 - 1501
  • [46] Technological development and advances in single-photon emission computed tomography/computed tomography
    Seo, Youngho
    Mari, Carina
    Hasegawa, Bruce H.
    SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 177 - 198
  • [47] The value of 99mTc-sestamibi single-photon emission computed tomography-computed tomography in the evaluation and risk stratification of renal masses
    Sistani, Golmehr
    Bjazevic, Jennifer
    Kassam, Zahra
    Romsa, Jonathan
    Pautler, Stephen
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2021, 15 (06): : 197 - 201
  • [48] 99mTc-labeled-2-arylbenzoxazole derivatives as potential Aβ imaging probes for single-photon emission computed tomography
    Wang, Xuedan
    Cui, Mengchao
    Jia, Jianhua
    Liu, Boli
    EUROPEAN JOURNAL OF MEDICINAL CHEMISTRY, 2015, 89 : 331 - 339
  • [49] Incremental value of single-photon emission computed tomography/computed tomography in the diagnosis of active condylar hyperplasia
    Agarwal, Krishan Kant
    Mukherjee, Anirban
    ArunRaj, S. T.
    Tripathi, Madhavi
    Bal, Chandrasekhar
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (01) : 29 - 34
  • [50] SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    KNOLL, GF
    PROCEEDINGS OF THE IEEE, 1983, 71 (03) : 320 - 329