99mTc-methoxyisobutylisonitrile single-photon emission computed tomography/computed tomography parathyroid imaging in the diagnosis of functional parathyroid cysts: an initial experience

被引:1
|
作者
Wei, Yushan [1 ,2 ]
Liu, Yan [1 ]
Yang, Lulu [1 ]
Xu, Hui [1 ]
Yang, Yiyuan [1 ]
Liang, Yiqian [1 ]
Zhang, Yuchen [1 ]
Yang, Aimin [1 ]
Tang, Xiaojiang [3 ]
Xue, Jianjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Nucl Med, Affiliated Hosp 1, 277 West Yanta Rd, Xian, Peoples R China
[2] Xian Chest Hosp, Dept Med Imaging, Xian, Peoples R China
[3] Xi An Jiao Tong Univ, Dept Breast Surg, Affiliated Hosp 1, Xian, Peoples R China
关键词
Parathyroid cyst (PCs); functional parathyroid cysts ( FPCs); single-photon emission computed; tomography/computed tomography imaging (SPECT/CT imaging); 99mTc-methoxyisobutylisonitrile (99mTc-MIBI); hyperparathyroidism (HPT); F-18-FLUOROCHOLINE PET/CT; POSSIBLE PITFALL; HYPERPARATHYROIDISM; LOCALIZATION; SENSITIVITY; ASPIRATION; LESIONS; ENTITY;
D O I
10.21037/gs-23-273
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Functional parathyroid cysts ( FPCs) are rare and difficult to diagnose with noninvasive methods. The aim of this study was to evaluate the diagnostic value of 99mTc-methoxyisobutylisonitrile (99mTcMIBI) single-photon emission computed tomography/computerized tomography (SPECT/CT) parathyroid imaging in the diagnosis of FPCs and to account for its performance. Methods: The data from 10 patients with suspected parathyroid cysts (PCs) who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2012 and 2022 were retrospectively evaluated. The diagnostic value of 99mTc-MIBI SPECT/CT parathyroid imaging for FPCs was analyzed. Results: Surgical resection was performed in six cases and parathyroid puncture was performed in four cases. The sensitivity of 99mTc-MIBI SPECT/CT for FPCs was 100.0% (3/3), with a specificity of 100.0% (7/7) and an accuracy of 100.0% (10/ 10). The postoperative pathological findings in three cases of FPCs were parathyroid adenoma, parathyroid adenoma with hemorrhage, and parathyroid adenoma with cystic degeneration, respectively. The diagnostic accuracy of ultrasound and CT for PCs was only 22.22% (2/9) and 25.0% (1/4), respectively, and neither modality could indicate whether the cysts were functional or not. Conclusions: 99mTc-MIBI parathyroid SPECT/CT imaging has a high value in the diagnosis of FPCs in patients with suspected PCs, and an intense ring-shaped accumulation of radioactivity in the cyst wall on 99mTc-MIBI imaging suggests that the patient may have FPCs.
引用
收藏
页码:32 / 44
页数:13
相关论文
共 50 条
  • [31] Imaging gliomas with positron emission tomography and single-photon emission computed tomography
    Bénard, F
    Romsa, J
    Hustinx, R
    SEMINARS IN NUCLEAR MEDICINE, 2003, 33 (02) : 148 - 162
  • [32] The Economic Value of Hybrid Single-photon Emission Computed Tomography With Computed Tomography Imaging in Pulmonary Embolism Diagnosis
    Toney, Lauren K.
    Kim, Richard D.
    Palli, Swetha R.
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (09) : 1110 - 1123
  • [33] Single-Photon Emission Computed Tomography Is an Ambiguous Imaging Method on Initial Diagnosis for Acute Encephalopathy
    Yamanaka, Gaku
    Morishita, Nastumi
    Oana, Shingo
    Takeshita, Mika
    Morichi, Shinichiro
    Ishida, Yu
    Kashiwagi, Yasuyo
    Kawashima, Hisashi
    NEUROPEDIATRICS, 2016, 47 (01) : 39 - 45
  • [34] Utility of Single-Photon Emission Computed Tomography/Computed Tomography Fusion Imaging With 99mTc-Pyrophosphate Scintigraphy in the Assessment of Cardiac Transthyretin Amyloidosis
    Tsuda, Noriko
    Shiraishi, Shinya
    Oda, Seitaro
    Ogasawara, Koji
    Sakamoto, Fumi
    Tomiguchi, Seiji
    Fujisue, Koichiro
    Takashio, Seiji
    Izumiya, Yasuhiro
    Tsujita, Kenichi
    Ando, Yukio
    Yamashita, Yasuyuki
    CIRCULATION JOURNAL, 2018, 82 (07) : 1970 - 1971
  • [35] Single-photon emission computed tomography/computed tomography in brain tumors
    Schillaci, Orazio
    Filippi, Luca
    Manni, Carlo
    Santoni, Riccardo
    SEMINARS IN NUCLEAR MEDICINE, 2007, 37 (01) : 34 - 47
  • [36] Single-photon emission computed tomography/computed tomography in abdominal diseases
    Schillaci, Orazio
    Filippi, Luca
    Danieli, Roberta
    Simonetti, Giovanni
    SEMINARS IN NUCLEAR MEDICINE, 2007, 37 (01) : 48 - 61
  • [37] The value of 99mTc-methylene diphosphonate single photon emission computed tomography/computed tomography in diagnosis of fibrous dysplasia
    Linqi Zhang
    Qiao He
    Wei Li
    Rusen Zhang
    BMC Medical Imaging, 17
  • [38] The value of 99mTc-methylene diphosphonate single photon emission computed tomography/computed tomography in diagnosis of fibrous dysplasia
    Zhang, Linqi
    He, Qiao
    Li, Wei
    Zhang, Rusen
    BMC MEDICAL IMAGING, 2017, 17
  • [39] Accuracy of Dual Phase Single-Photon Emission Computed Tomography/Computed Tomography in Primary Hyperparathyroidism: Correlation With Serum Parathyroid Hormone Levels
    Koberstein, Wade
    Fung, Christopher
    Romaniuk, Kristy
    Abele, Jonathan T.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2016, 67 (02): : 115 - 121
  • [40] Implantable cardioverter-defibrillator lead infection detected by 99mTc-sulesomab single-photon emission computed tomography/computed tomography 'fusion' imaging
    Schiavo, Riccardo
    Ricci, Alessandra
    Pontillo, Daniele
    Bernardini, Giuliana
    Melacrinis, Francesca Fiore
    Maccafeo, Stefano
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (11) : 883 - 884