99mTc-methoxyisobutylisonitrile single-photon emission computed tomography/computed tomography parathyroid imaging in the diagnosis of functional parathyroid cysts: an initial experience

被引:1
|
作者
Wei, Yushan [1 ,2 ]
Liu, Yan [1 ]
Yang, Lulu [1 ]
Xu, Hui [1 ]
Yang, Yiyuan [1 ]
Liang, Yiqian [1 ]
Zhang, Yuchen [1 ]
Yang, Aimin [1 ]
Tang, Xiaojiang [3 ]
Xue, Jianjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Nucl Med, Affiliated Hosp 1, 277 West Yanta Rd, Xian, Peoples R China
[2] Xian Chest Hosp, Dept Med Imaging, Xian, Peoples R China
[3] Xi An Jiao Tong Univ, Dept Breast Surg, Affiliated Hosp 1, Xian, Peoples R China
关键词
Parathyroid cyst (PCs); functional parathyroid cysts ( FPCs); single-photon emission computed; tomography/computed tomography imaging (SPECT/CT imaging); 99mTc-methoxyisobutylisonitrile (99mTc-MIBI); hyperparathyroidism (HPT); F-18-FLUOROCHOLINE PET/CT; POSSIBLE PITFALL; HYPERPARATHYROIDISM; LOCALIZATION; SENSITIVITY; ASPIRATION; LESIONS; ENTITY;
D O I
10.21037/gs-23-273
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Functional parathyroid cysts ( FPCs) are rare and difficult to diagnose with noninvasive methods. The aim of this study was to evaluate the diagnostic value of 99mTc-methoxyisobutylisonitrile (99mTcMIBI) single-photon emission computed tomography/computerized tomography (SPECT/CT) parathyroid imaging in the diagnosis of FPCs and to account for its performance. Methods: The data from 10 patients with suspected parathyroid cysts (PCs) who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2012 and 2022 were retrospectively evaluated. The diagnostic value of 99mTc-MIBI SPECT/CT parathyroid imaging for FPCs was analyzed. Results: Surgical resection was performed in six cases and parathyroid puncture was performed in four cases. The sensitivity of 99mTc-MIBI SPECT/CT for FPCs was 100.0% (3/3), with a specificity of 100.0% (7/7) and an accuracy of 100.0% (10/ 10). The postoperative pathological findings in three cases of FPCs were parathyroid adenoma, parathyroid adenoma with hemorrhage, and parathyroid adenoma with cystic degeneration, respectively. The diagnostic accuracy of ultrasound and CT for PCs was only 22.22% (2/9) and 25.0% (1/4), respectively, and neither modality could indicate whether the cysts were functional or not. Conclusions: 99mTc-MIBI parathyroid SPECT/CT imaging has a high value in the diagnosis of FPCs in patients with suspected PCs, and an intense ring-shaped accumulation of radioactivity in the cyst wall on 99mTc-MIBI imaging suggests that the patient may have FPCs.
引用
收藏
页码:32 / 44
页数:13
相关论文
共 50 条
  • [1] Parathyroid imaging using single-photon emission computed tomography/computed tomography: single institution experience
    Guerrouj, H.
    Benrais, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S287 - S287
  • [2] The Detection of Preoperative Parathyroid Lesions: The Success of Ultrasonography, Technetium-99m Methoxyisobutylisonitrile Parathyroid Scintigraphy, and Single-Photon Emission Computed Tomography-Computed Tomography
    Baser, Ozden Ozdemir
    Koseoglu, Derya
    Cetin, Zeynep
    Catak, Merve
    Berker, Dilek
    ENDOCRINE PRACTICE, 2021, 27 (12) : 1193 - 1198
  • [3] The role of single-photon emission computed tomography/computed tomography in localizing parathyroid adenoma
    Dasgupta, Dhruba J.
    Navalkissoor, Shaunak
    Ganatra, Rakesh
    Buscombe, John
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (07) : 621 - 626
  • [4] Comparison of 99mTc-methoxyisobutylisonitrile myocardial single-photon emission computed tomography and electron beam computed tomography for detecting coronary artery disease in patients with no myocardial infarction
    姚稚明
    李伟
    屈婉莹
    周诚
    何青
    季福绥
    中华医学杂志(英文版), 2004, (05) : 61 - 66
  • [5] Comparison of 99mTc-methoxyisobutylisonitrile myocardial single-photon emission computed tomography and electron beam computed tomography for detecting coronary artery disease in patients with no myocardial infarction
    Yao, ZM
    Li, W
    Qu, WY
    Zhou, C
    He, Q
    Ji, FS
    CHINESE MEDICAL JOURNAL, 2004, 117 (05) : 700 - 705
  • [6] 99mTc-Ethambutol Scintigraphy with Single-Photon Emission Computed Tomography/Computed Tomography in Lymph Node Tuberculosis: An Initial Experience
    Bhattacharya, Bisakh
    Damle, Nishikant
    Ranjan, Piyush
    Arora, Geetanjali
    Prakash, Sneha
    Nischal, Neeraj
    Jorwal, Pankaj
    Kumar, Arvind
    Tyagi, Apoorva
    Wig, Naveet
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2022, 37 (04): : 323 - 328
  • [7] 99mTc-MIBI single photon emission computed tomography/computed tomography for the incidental detection of rare parathyroid carcinoma
    Chen, Zejun
    Fu, Jingjing
    Shao, Qing
    Zhou, Bin
    Wang, Feng
    MEDICINE, 2018, 97 (40)
  • [8] Advantages of the 99mTc-sestamibi Single-Photon Emission Computed Tomography/Computed Tomography in Occult Parathyroid Adenoma and Concomitant Thyroid Papillary Carcinoma
    Cadena-Pineros, Enrique
    Amelia De los Reyes, Carmen
    Llamas-Olier, Augusto
    Ernesto Romero-Rojas, Alfredo
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 34 (02): : 150 - 152
  • [9] Less frequent cardiac and extracardiac findings during 99mTc-methoxyisobutylisonitrile myocardial perfusion single-photon emission computed tomography with radiological correlates
    Qutbi, Mohsen
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2020, 35 (02): : 147 - 153
  • [10] Incremental value of 99mTc-MIBI single-photon emission computed tomography/computed tomography fusion imaging for the diagnosis of secondary hyperparathyroidism
    Peng, Ye
    Pan, Guixia
    Zhao, Bo
    Zuo, Changjing
    Wang, Yingqiu
    Chen, Rui
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (09) : 767 - 771