The robot doesn't lie: real-life validation of robotic performance metrics

被引:11
|
作者
Quinn, Kristen M. [1 ]
Chen, Xiaodong [2 ]
Runge, Louis T. [1 ]
Pieper, Heidi [3 ]
Renton, David [2 ]
Meara, Michael [2 ]
Collins, Courtney [2 ]
Griffiths, Claire [3 ]
Husain, Syed [4 ]
机构
[1] Med Univ South Carolina, Dept Surg, 96 Jonathan Lucas St Room CSB 417, Charleston, SC 29425 USA
[2] Ohio State Univ, Wexner Med Ctr, Div Gastrointestinal Surg, Columbus, OH 43210 USA
[3] Ohio State Univ, Wexner Med Ctr, Ctr Minimally Invas Surg, Columbus, OH 43210 USA
[4] Ohio State Univ, Wexner Med Ctr, Div Colorectal Surg, Columbus, OH 43210 USA
关键词
Surgical education; Operative autonomy; Robotic surgery; Surgical training; GENERAL-SURGERY RESIDENTS; READINESS;
D O I
10.1007/s00464-022-09707-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Degree of resident participation in a case is often used as a surrogate marker for operative autonomy, an essential element of surgical resident training. Previous studies have demonstrated a considerable disagreement between the perceptions of attending surgeons and trainees when it comes to estimating operative participation. The Da Vinci Surgical System dual console interface allows machine generated measurements of trainee's active participation, which has the potential to obviate the need for labor intensive direct observation of surgical procedures. However, the robotic metrics require validation. We present a comparison of operative participation as perceived by the resident, faculty, trained research staff observer (gold standard), and robotic machine generated data. Methods A total of 28 consecutive robotic inguinal hernia repair procedures were observed by research staff. Operative time, percent active time for the resident, and number of handoffs between the resident and attending were recorded by trained research staff in the operating room and the Da Vinci Surgical System. Attending and resident evaluations of operative performance and perceptions of percent active time for the resident were collected using standardized forms and compared with the research staff observed values and the robot-generated console data. Wilcoxon two-sample tests and Pearson Correlation coefficients statistical analysis were performed. Results Robotic inguinal hernia repair cases had a mean operative time of 91.3 (30) minutes and an attending-rated mean difficulty of 3.1 (1.26) out of 5. Residents were recorded to be the active surgeon 71.8% (17.7) of the total case time by research staff. There was a strong correlation (r = 0.77) in number of handoffs between faculty and trainee as recorded by the research staff and robot (4.28 (2.01) vs. 5.8 (3.04) respectively). The robotic machine generated data demonstrated the highest degree of association when compared to the gold standard (research staff observed data), with r = 0.98, p < 0.0001. Lower levels of association were seen with resident reported (r = 0.66) perceptions and faculty-reported (r = 0.55) perceptions of resident active operative time. Conclusions Our findings suggest that robot-generated performance metrics are an extremely accurate and reliable measure of intraoperative resident participation indicated by a very strong correlation with the data recorded by research staff's direct observation of the case. Residents demonstrated a more accurate awareness of their degree of participation compared with faculty surgeons. With high accuracy and ease of use, robotic surgical system performance metrics have the potential to be a valuable tool in surgical training and skill assessment.
引用
收藏
页码:5547 / 5552
页数:6
相关论文
共 50 条
  • [41] Performance of child restraint systems in real-life lateral collisions
    Langwieder, K
    Hell, W
    Willson, H
    40TH STAPP CAR CRASH CONFERENCE PROCEEDINGS, 1996, P-30 : 391 - 404
  • [42] Quality Assessment of Real-Life Performance of Home Mechanical Ventilators
    Garmendia, Onintza
    Farre, Ramon
    Gonzalez, Monica
    Luz Alonso-Alvarez, Ma
    Perez, Noelia
    Marti, Sergi
    Montserrat, Josep M.
    ARCHIVOS DE BRONCONEUMOLOGIA, 2020, 56 (04): : 258 - 259
  • [43] Assessment of esophagogastroduodenoscopy skills on simulators before real-life performance
    Nielsen, Anders Bo
    Pedersen, Finn Moller
    Laursen, Christian B.
    Konge, Lars
    Laursen, Stig
    ENDOSCOPY INTERNATIONAL OPEN, 2022, 10 (06) : E815 - E823
  • [44] CONCURRENT VALIDATION OF AUTOMATED EVALUATION OF ROBOTIC SURGERY PERFORMANCE: CORRELATION OF PERFORMANCE METRICS TO GLOBAL EVALUATIVE ASSESSMENT OF ROBOTIC SURGERY (GEARS)
    Hung, Andrew
    Chen, Jian
    Jarc, Anthony
    Djaladat, Hooman
    Gill, Inderbir
    JOURNAL OF UROLOGY, 2017, 197 (04): : E693 - E693
  • [45] A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study
    Schoot, Tessa S.
    Weenk, Mariska
    van de Belt, Tom H.
    Engelen, Lucien J. L. P. G.
    van Goor, Harry
    Bredie, Sebastian J. H.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2016, 18 (05)
  • [46] Assessing snacking and drinking behavior in Real-Life Settings: Validation of the SnackBox technology
    de Gooijer, Femke J.
    van Kraaij, Alex
    Fabius, Jasper
    Hermsen, Sander
    Feskens, Edith J. M.
    Camps, Guido
    FOOD QUALITY AND PREFERENCE, 2023, 112
  • [47] Real-Life Validation of Reduced Reward Processing in Emerging Adults With Depressive Symptoms
    Bakker, Jindra Myrthe
    Goossens, Liesbet
    Lange, Iris
    Michielse, Stijn
    Schruers, Koen
    Lieverse, Ritsaert
    Marcelis, Machteld
    van Amelsvoort, Therese
    van Os, Jim
    Myin-Germeys, Inez
    Wichers, Marieke
    JOURNAL OF ABNORMAL PSYCHOLOGY, 2017, 126 (06) : 713 - 725
  • [48] AN OBJECTIVE ASSESSMENT OF PERFORMANCE DURING ROBOTIC PARTIAL NEPHRECTOMY: VALIDATION AND CORRELATION OF AUTOMATED PERFORMANCE METRICS WITH OUTCOMES
    Ghodoussipour, Saum
    Chen, Jian
    Nguyen, Jessica
    Reddy, Sharath
    Shakir, Aliasger
    Patel, Rut
    Gill, Inderbir
    Hung, Andrew
    JOURNAL OF UROLOGY, 2019, 201 (04): : E483 - E483
  • [49] From Clinical Trial Efficacy to Real-Life Effectiveness: Why Conventional Metrics do not Work
    Boissel, Jean-Pierre
    Cogny, Frederic
    Marko, Nicholas
    Boissel, Francois-Henri
    DRUGS-REAL WORLD OUTCOMES, 2019, 6 (03) : 125 - 132
  • [50] REAL-LIFE IMPACT ON GLUCOSE METRICS OF USING OR NOT USING THE FREESTYLE LIBRE 2 ALARM SYSTEM
    Barajas Galindo, D. E.
    Ramos Bachiller, B.
    Antequera Gonzalez, M.
    Gonzalez Arnaiz, E.
    Gonzalez Roza, L.
    Ballesteros Pomar, M. D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A143 - A143