The robot doesn't lie: real-life validation of robotic performance metrics

被引:11
|
作者
Quinn, Kristen M. [1 ]
Chen, Xiaodong [2 ]
Runge, Louis T. [1 ]
Pieper, Heidi [3 ]
Renton, David [2 ]
Meara, Michael [2 ]
Collins, Courtney [2 ]
Griffiths, Claire [3 ]
Husain, Syed [4 ]
机构
[1] Med Univ South Carolina, Dept Surg, 96 Jonathan Lucas St Room CSB 417, Charleston, SC 29425 USA
[2] Ohio State Univ, Wexner Med Ctr, Div Gastrointestinal Surg, Columbus, OH 43210 USA
[3] Ohio State Univ, Wexner Med Ctr, Ctr Minimally Invas Surg, Columbus, OH 43210 USA
[4] Ohio State Univ, Wexner Med Ctr, Div Colorectal Surg, Columbus, OH 43210 USA
关键词
Surgical education; Operative autonomy; Robotic surgery; Surgical training; GENERAL-SURGERY RESIDENTS; READINESS;
D O I
10.1007/s00464-022-09707-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Degree of resident participation in a case is often used as a surrogate marker for operative autonomy, an essential element of surgical resident training. Previous studies have demonstrated a considerable disagreement between the perceptions of attending surgeons and trainees when it comes to estimating operative participation. The Da Vinci Surgical System dual console interface allows machine generated measurements of trainee's active participation, which has the potential to obviate the need for labor intensive direct observation of surgical procedures. However, the robotic metrics require validation. We present a comparison of operative participation as perceived by the resident, faculty, trained research staff observer (gold standard), and robotic machine generated data. Methods A total of 28 consecutive robotic inguinal hernia repair procedures were observed by research staff. Operative time, percent active time for the resident, and number of handoffs between the resident and attending were recorded by trained research staff in the operating room and the Da Vinci Surgical System. Attending and resident evaluations of operative performance and perceptions of percent active time for the resident were collected using standardized forms and compared with the research staff observed values and the robot-generated console data. Wilcoxon two-sample tests and Pearson Correlation coefficients statistical analysis were performed. Results Robotic inguinal hernia repair cases had a mean operative time of 91.3 (30) minutes and an attending-rated mean difficulty of 3.1 (1.26) out of 5. Residents were recorded to be the active surgeon 71.8% (17.7) of the total case time by research staff. There was a strong correlation (r = 0.77) in number of handoffs between faculty and trainee as recorded by the research staff and robot (4.28 (2.01) vs. 5.8 (3.04) respectively). The robotic machine generated data demonstrated the highest degree of association when compared to the gold standard (research staff observed data), with r = 0.98, p < 0.0001. Lower levels of association were seen with resident reported (r = 0.66) perceptions and faculty-reported (r = 0.55) perceptions of resident active operative time. Conclusions Our findings suggest that robot-generated performance metrics are an extremely accurate and reliable measure of intraoperative resident participation indicated by a very strong correlation with the data recorded by research staff's direct observation of the case. Residents demonstrated a more accurate awareness of their degree of participation compared with faculty surgeons. With high accuracy and ease of use, robotic surgical system performance metrics have the potential to be a valuable tool in surgical training and skill assessment.
引用
收藏
页码:5547 / 5552
页数:6
相关论文
共 50 条
  • [31] Validation of dipslides as a tool for environmental sampling in a real-life hospital setting
    Ibfelt, T.
    Foged, C.
    Andersen, L. P.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2014, 33 (05) : 809 - 813
  • [32] Validation of dipslides as a tool for environmental sampling in a real-life hospital setting
    T. Ibfelt
    C. Foged
    L. P. Andersen
    European Journal of Clinical Microbiology & Infectious Diseases, 2014, 33 : 809 - 813
  • [33] Schnitzler syndrome: validation and applicability of diagnostic criteria in real-life patients
    Gusdorf, L.
    Asli, B.
    Barbarot, S.
    Neel, A.
    Masseau, A.
    Puechal, X.
    Gottenberg, J-E.
    Grateau, G.
    Blanchard-Delaunay, C.
    Rizzi, R.
    Lifermann, F.
    Kyndt, X.
    Aubin, F.
    Bessis, D.
    Boye, T.
    Gayet, S.
    Rongioletti, F.
    Sauleau, E.
    Fermand, J-P.
    Lipsker, D.
    ALLERGY, 2017, 72 (02) : 177 - 182
  • [34] Real-life validation of a sample pooling strategy for screening of hepatitis C
    Aguilera, Antonio
    Fuentes, Ana
    Cea, Maria
    Carracedo, Raquel
    Vinuela, Laura
    Ordonez, Patricia
    Lopez-Fabal, Fatima
    Saez, Elena
    Cebrian, Ruben
    Perez-Revilla, Alfredo
    Pereira, Sara
    De Salazar, Adolfo
    Garcia, Federico
    CLINICAL MICROBIOLOGY AND INFECTION, 2023, 29 (01) : 112.e1 - 112.e4
  • [36] SIMULATION OF ROBOT-ASSISTED WSN LOCALIZATION USING REAL-LIFE DATA
    Marks, Michal
    Niewiadomska-Szynkiewicz, Ewa
    PROCEEDINGS - 30TH EUROPEAN CONFERENCE ON MODELLING AND SIMULATION ECMS 2016, 2016, : 607 - 613
  • [37] Voice Interaction Recognition Design in Real-Life Scenario Mobile Robot Applications
    Li, Shih-An
    Liu, Yu-Ying
    Chen, Yun-Chien
    Feng, Hsuan-Ming
    Shen, Pi-Kang
    Wu, Yu-Che
    APPLIED SCIENCES-BASEL, 2023, 13 (05):
  • [38] The Ten Commandments for Translating Simulation Results Into Real-life Performance
    Wenzler, Ivo
    SIMULATION & GAMING, 2009, 40 (01) : 98 - 109
  • [39] Diagnostic performance of the MelaFind device in a real-life clinical setting
    Fink, Christine
    Jaeger, Claudia
    Jaeger, Katharina
    Haenssle, Holger A.
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2017, 15 (04): : 414 - 419
  • [40] Web 2.0 presentation tools as an alternative to real-life performance
    Casteleyn, Jordi
    Mottart, Andre
    Van Vooren, Valerie
    3RD WORLD CONFERENCE ON LEARNING, TEACHING AND EDUCATIONAL LEADERSHIP, 2013, 93 : 221 - 224