Research on the evolutionary history of the morphological structure of cotton seeds: a new perspective based on high-resolution micro-CT technology

被引:0
|
作者
Li, Yuankun [1 ,2 ]
Huang, Guanmin [2 ]
Lu, Xianju [2 ]
Gu, Shenghao [2 ]
Zhang, Ying [2 ]
Li, Dazhuang [2 ]
Guo, Minkun [2 ]
Zhang, Yongjiang [1 ]
Guo, Xinyu [2 ]
机构
[1] Hebei Agr Univ, Coll Agron, State Key Lab North China Crop Improvement & Regul, Key Lab Crop Growth Regulat Hebei Prov, Baoding, Peoples R China
[2] Beijing Acad Agr & Forestry Sci, Informat Technol Res Ctr, Beijing Key Lab Digital Plant, Beijing, Peoples R China
来源
关键词
cotton; seed morphological structure; micro-CT; phenotypic analysis; temporal succession; MU-CT; TOMOGRAPHY; SIZE; SELECTION;
D O I
10.3389/fpls.2023.1219476
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Cotton (Gossypium hirsutum L.) seed morphological structure has a significant impact on the germination, growth and quality formation. However, the wide variation of cotton seed morphology makes it difficult to achieve quantitative analysis using traditional phenotype acquisition methods. In recent years, the application of micro-CT technology has made it possible to analyze the three-dimensional morphological structure of seeds, and has shown technical advantages in accurate identification of seed phenotypes. In this study, we reconstructed the seed morphological structure based on micro-CT technology, deep neural network Unet-3D model, and threshold segmentation methods, extracted 11 basics phenotypes traits, and constructed three new phenotype traits of seed coat specific surface area, seed coat thickness ratio and seed density ratio, using 102 cotton germplasm resources with clear year characteristics. Our results show that there is a significant positive correlation (P< 0.001) between the cotton seed size and that of the seed kernel and seed coat volume, with correlation coefficients ranging from 0.51 to 0.92, while the cavity volume has a lower correlation with other phenotype indicators (r<0.37, P< 0.001). Comparison of changes in Chinese self-bred varieties showed that seed volume, seed surface area, seed coat volume, cavity volume and seed coat thickness increased by 11.39%, 10.10%, 18.67%, 115.76% and 7.95%, respectively, while seed kernel volume, seed kernel surface area and seed fullness decreased by 7.01%, 0.72% and 16.25%. Combining with the results of cluster analysis, during the hundred-year cultivation history of cotton in China, it showed that the specific surface area of seed structure decreased by 1.27%, the relative thickness of seed coat increased by 8.70%, and the compactness of seed structure increased by 50.17%. Furthermore, the new indicators developed based on micro-CT technology can fully consider the three-dimensional morphological structure and cross-sectional characteristics among the indicators and reflect technical advantages. In this study, we constructed a microscopic phenotype research system for cotton seeds, revealing the morphological changes of cotton seeds with the year in China and providing a theoretical basis for the quantitative analysis and evaluation of seed morphology.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] High-resolution local imaging using a micro-CT
    Lee, Soo Yeol
    Cho, Min Hyoung
    Choi, Jeong Min
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 137 - 140
  • [2] High-resolution micro-CT imaging: A new technique for early detection of osteoporosis
    Yang, J
    Pham, SM
    Grabbe, DL
    RADIOLOGY, 2002, 225 : 418 - 418
  • [3] Fast high-resolution micro-CT with exact reconstruction methods
    Varslot, T.
    Kingston, A.
    Sheppard, A.
    Sakellariou, A.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [4] Comparative morphological examination of vertebral bodies of teleost fish using high-resolution micro-CT scans
    Sakashita, Misaki
    Sato, Mao
    Kondo, Shigeru
    JOURNAL OF MORPHOLOGY, 2019, 280 (06) : 778 - 795
  • [5] Segmentation and Visualization of a Large, High-Resolution Micro-CT Data of Mice
    Chityala, Ravishankar
    Pudipeddi, Sridevi
    Arensten, Luke
    Hui, Susanta
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (02) : 302 - 308
  • [6] Segmentation and Visualization of a Large, High-Resolution Micro-CT Data of Mice
    Ravishankar Chityala
    Sridevi Pudipeddi
    Luke Arensten
    Susanta Hui
    Journal of Digital Imaging, 2013, 26 : 302 - 308
  • [7] High-resolution in-vivo micro-CT scanner for small animals
    Sasov, A
    Dewaele, D
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 256 - 264
  • [8] High-resolution in-vivo micro-CT scanner for small animals
    Sasov, A
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 705 - 710
  • [9] Morphological examination of abdominal vertebral bodies from grass carp using high-resolution micro-CT scans
    Barak, Meir M.
    Schlott, James
    Gundersen, Laura
    Diaz, Giovanni
    Rhee, Vanessa
    Villoth, Naomi
    Ferber, Alexandra
    Blair, Salvatore
    JOURNAL OF ANATOMY, 2024, 245 (01) : 84 - 96
  • [10] Electrical Stimulation in the Human Cochlea: A Computational Study Based on High-Resolution Micro-CT Scans
    Bai, Siwei
    Encke, Joerg
    Obando-Leiton, Miguel
    Weiss, Robin
    Schaefer, Friederike
    Eberharter, Jakob
    Boehnke, Frank
    Hemmert, Werner
    FRONTIERS IN NEUROSCIENCE, 2019, 13