Research on the evolutionary history of the morphological structure of cotton seeds: a new perspective based on high-resolution micro-CT technology

被引:0
|
作者
Li, Yuankun [1 ,2 ]
Huang, Guanmin [2 ]
Lu, Xianju [2 ]
Gu, Shenghao [2 ]
Zhang, Ying [2 ]
Li, Dazhuang [2 ]
Guo, Minkun [2 ]
Zhang, Yongjiang [1 ]
Guo, Xinyu [2 ]
机构
[1] Hebei Agr Univ, Coll Agron, State Key Lab North China Crop Improvement & Regul, Key Lab Crop Growth Regulat Hebei Prov, Baoding, Peoples R China
[2] Beijing Acad Agr & Forestry Sci, Informat Technol Res Ctr, Beijing Key Lab Digital Plant, Beijing, Peoples R China
来源
关键词
cotton; seed morphological structure; micro-CT; phenotypic analysis; temporal succession; MU-CT; TOMOGRAPHY; SIZE; SELECTION;
D O I
10.3389/fpls.2023.1219476
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Cotton (Gossypium hirsutum L.) seed morphological structure has a significant impact on the germination, growth and quality formation. However, the wide variation of cotton seed morphology makes it difficult to achieve quantitative analysis using traditional phenotype acquisition methods. In recent years, the application of micro-CT technology has made it possible to analyze the three-dimensional morphological structure of seeds, and has shown technical advantages in accurate identification of seed phenotypes. In this study, we reconstructed the seed morphological structure based on micro-CT technology, deep neural network Unet-3D model, and threshold segmentation methods, extracted 11 basics phenotypes traits, and constructed three new phenotype traits of seed coat specific surface area, seed coat thickness ratio and seed density ratio, using 102 cotton germplasm resources with clear year characteristics. Our results show that there is a significant positive correlation (P< 0.001) between the cotton seed size and that of the seed kernel and seed coat volume, with correlation coefficients ranging from 0.51 to 0.92, while the cavity volume has a lower correlation with other phenotype indicators (r<0.37, P< 0.001). Comparison of changes in Chinese self-bred varieties showed that seed volume, seed surface area, seed coat volume, cavity volume and seed coat thickness increased by 11.39%, 10.10%, 18.67%, 115.76% and 7.95%, respectively, while seed kernel volume, seed kernel surface area and seed fullness decreased by 7.01%, 0.72% and 16.25%. Combining with the results of cluster analysis, during the hundred-year cultivation history of cotton in China, it showed that the specific surface area of seed structure decreased by 1.27%, the relative thickness of seed coat increased by 8.70%, and the compactness of seed structure increased by 50.17%. Furthermore, the new indicators developed based on micro-CT technology can fully consider the three-dimensional morphological structure and cross-sectional characteristics among the indicators and reflect technical advantages. In this study, we constructed a microscopic phenotype research system for cotton seeds, revealing the morphological changes of cotton seeds with the year in China and providing a theoretical basis for the quantitative analysis and evaluation of seed morphology.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Anatomical Variations of the Human Cochlea Determined from Micro-CT and High-Resolution CT Imaging and Reconstruction
    Tang, Jie
    Tang, Xianglong
    Li, Zhenhua
    Liu, Yikang
    Tan, Songhua
    Li, Heng
    Ke, Rongdan
    Wang, Zhi
    Gong, Li
    Tang, Anzhou
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2018, 301 (06): : 1086 - 1095
  • [22] The impact of (simulated) resolution on breast cancer diagnosis based on high-resolution 3D micro-CT microcalcification images
    Brahimetaj, Redona
    Cornelis, Jan
    Van Ongeval, Chantal
    De Mey, Johan
    Jansen, Bart
    MEDICAL PHYSICS, 2024, 51 (03) : 1754 - 1762
  • [23] High-resolution 3D micro-CT imaging of breast microcalcifications: a preliminary analysis
    Willekens, Inneke
    Van de Casteele, Elke
    Buls, Nico
    Temmermans, Frederik
    Jansen, Bart
    Deklerck, Rudi
    de Mey, Johan
    BMC CANCER, 2014, 14
  • [24] High-resolution 3D micro-CT imaging of breast microcalcifications: a preliminary analysis
    Inneke Willekens
    Elke Van de Casteele
    Nico Buls
    Frederik Temmermans
    Bart Jansen
    Rudi Deklerck
    Johan de Mey
    BMC Cancer, 14
  • [25] High-Resolution Micro-CT for Morphologic and Quantitative Assessment of the Sinusoid in Human Cavernous Hemangioma of the Liver
    Duan, Jinghao
    Hu, Chunhong
    Chen, Hua
    PLOS ONE, 2013, 8 (01):
  • [26] High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT
    Nahrendorf, Matthias
    Badea, Cristian
    Hedlund, Laurence W.
    Figueiredo, Jose-Luiz
    Sosnovik, David E.
    Johnson, G. Allan
    Weissleder, Ralph
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 292 (06): : H3172 - H3178
  • [27] A PIPELINE FOR QUANTITATIVE ANALYSIS OF HIGH-RESOLUTION MICRO-CT OF THE VASCULATURE OF THE FETO-PLACENTAL COTYLEDON
    Jackson, Toby
    Srinivasan, Vijayalaksmi
    Spring, Mary
    James, Jo
    Clark, Alys
    PLACENTA, 2023, 140 : E66 - E66
  • [28] High-resolution micro-CT scanning as an innovative tool for evaluating dental hard tissue development
    Dong, Guangyan
    Dong, Qianqian
    Liu, Yi
    Lou, Beiyan
    Feng, Jin
    Wang, Kejing
    Zhou, Xuedong
    Wu, Hongkun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 335 - 344
  • [29] Research on Cotton Yarn Based on Synchrotron Radiation 3D Micro-CT Imaging
    Shuaikang Han
    Qianhe Li
    Md All Amin Newton
    Yantao Gao
    Binjie Xin
    Ke Li
    Fibers and Polymers, 2024, 25 : 543 - 555
  • [30] Research on Cotton Yarn Based on Synchrotron Radiation 3D Micro-CT Imaging
    Han, Shuaikang
    Li, Qianhe
    Newton, Md All Amin
    Gao, Yantao
    Xin, Binjie
    Li, Ke
    FIBERS AND POLYMERS, 2024, 25 (02) : 543 - 555