Lu-177-PSMA dosimetry for kidneys and tumors based on SPECT images at two imaging time points

被引:6
|
作者
Chen, Gefei [1 ]
Lu, Zhonglin [1 ]
Jiang, Han [1 ,2 ]
Afshar-Oromieh, Ali [3 ]
Rominger, Axel [3 ]
Shi, Kuangyu [3 ]
Mok, Greta S. P. [1 ,4 ]
机构
[1] Univ Macau, Fac Sci & Technol, Dept Elect & Comp Engn, Biomed Imaging Lab BIG, Taipa, Macao, Peoples R China
[2] Fujian Med Univ, CT Ctr, PET, Union Hosp, Fuzhou, Fujian, Peoples R China
[3] Univ Bern, Bern Univ Hosp, Dept Nucl Med, Bern, Switzerland
[4] Univ Macau, Minist Educ, Frontiers Sci Ctr Precis Oncol, Taipa, Macao, Peoples R China
关键词
SPECT; Lu-177; PSMA; curve fitting; single time point; dosimetry; THERAPY;
D O I
10.3389/fmed.2023.1246881
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPersonalized dosimetry for Lu-177-PSMA treatment requires multiple-time-point SPECT/CT scans to calculate time-integrated activity (TIA). This study evaluates two-time-point (TTP) methods for TIA calculation for kidneys and tumors.MethodsA total of 18 patients treated with 3.7-7.4 GBq Lu-177 PSMA-617 were analyzed retrospectively, including 18 sets of left and right kidneys, as well as 45 tumors. Four quantitative SPECT/CT (4TP) were acquired at 2 h, 20 h, 40 h, 60 h (n = 11), or 200 h (n = 7) after treatment, and they were fit bi-exponentially as reference. The TTP method was fitted by a mono-exponential washout function using two selected imaging time points for kidneys. For tumors, one uptake and one washout phase were modeled, assuming linear (type I) and same (type II) uptake phase between 0 h to the first time point and mono-exponential washout thereafter. Two single-time-point (STP) methods were also implemented for comparison. TIA calculated by TTP and STP methods were compared with reference to the 4TP TIA.ResultsFor the kidneys, the TTP methods using 20 h-60 h and 40 h-200 h had smaller mean absolute errors of 8.05 +/- 6.05% and 4.95 +/- 3.98%, respectively, as compared to other combinations of time points and STP methods. For tumors, the type I and type II TTP methods using 20h-60 h and 40-200 h had smaller mean absolute errors of 6.14 +/- 5.19% and 12.22 +/- 4.44%, and 8.31 +/- 7.16% and 4.48 +/- 7.10%, respectively, as compared to other TTP and STP methods.ConclusionThe TTP methods based on later imaging time demonstrated fewer errors than the STP methods in kidney and tumor TIA. Imaging at 20 h-60 h and 40 h-200 h could simplify the dosimetry procedures with fewer TIA estimation errors.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Dosimetry of Lu-177 DKFZ-PSMA-617 for the treatment of metastatic prostate cancer using quantitative SPECT/CT
    Delker, Andreas
    Fendler, Wolfgang
    Brunegraf, Anika
    Gosewisch, Astrid
    Gildehaus, Franz Josef
    Bartenstein, Peter
    Boening, Guido
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [42] Correlation of PSMA PET and Post-therapy SPECT Imaging Metrics with Absorbed Doses for 177Lu-PSMA-617 Therapy
    Meyer, Catherine
    Yilmaz, Burcak
    Winters, Celeste
    Mench, Anna
    Mallak, Nadine
    Mittra, Erik
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [43] Towards fully automatized [177Lu]Lu-PSMA personalized dosimetry based on 360° CZT whole-body SPECT/CT: a proof-of-concept
    Dieudonne, Arnaud
    Terro, Aya
    Dumouchel, Arthur
    Perret, Solene
    Edet-Sanson, Agathe
    Vera, Pierre
    Hapdey, Sebastien
    Modzelewski, Romain
    Tonnelet, David
    Decazes, Pierre
    EJNMMI PHYSICS, 2025, 12 (01):
  • [44] Feasibility of total body dosimetry of Lu-177 SPECT-CT images recorded by a CZT camera
    Imbert, Laetitia
    Chevalier, Elodie
    Claudin, Marine
    Karcher, Gilles
    Marie, Pierre-Yves
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [45] Evaluation of intratherapeutic 177 Lu-HA-DOTATATE treatment in neuroendocrine tumors: dosimetry with SPECT, whole-body imaging and gamma probe
    Leonhaeuser, Britta
    Happel, Christian
    Groener, Daniel
    Bockisch, Benjamin
    Fiebich, Martin
    Hellwig, Dirk
    Gruenwald, Frank
    Kranert, Wolfgang Tilman
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2019, 58 (05): : 379 - 386
  • [46] Gamma Camera Calibration for SPECT Based Quantitative Imaging with LU-177
    D'Arienzo, M.
    Cazzato, M.
    Ungania, S.
    Cozzella, L.
    Iaccarino, G.
    D'Andrea, M.
    Strigari, L.
    Fenwick, A.
    Johansson, L.
    Cox, M.
    De Felice, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S331 - S332
  • [47] Impact of dead time on quantitative 177Lu-SPECT (QSPECT) and kidney dosimetry during PRRT
    Alessandro Desy
    Guillaume F. Bouvet
    Andrea Frezza
    Philippe Després
    Jean-Mathieu Beauregard
    EJNMMI Physics, 7
  • [48] Impact of dead time on quantitative 177Lu-SPECT (QSPECT) and kidney dosimetry during PRRT
    Desy, Alessandro
    Bouvet, Guillaume F.
    Frezza, Andrea
    Despres, Philippe
    Beauregard, Jean-Mathieu
    EJNMMI PHYSICS, 2020, 7 (01)
  • [49] Image-Based Bone Marrow Dosimetry in Patients Undergoing [177Lu]Lu-PSMA Radioligand Therapy
    Rumiantcev, M.
    Resch, S.
    Shen, X.
    Liubchenko, G.
    Brendel, M.
    Ziegler, S.
    Boening, G.
    Sheikh, G.
    Delker, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S164 - S164
  • [50] Deep transformer-based personalized dosimetry from SPECT/CT images: a hybrid approach for [177Lu]Lu-DOTATATE radiopharmaceutical therapy
    Mansouri, Zahra
    Salimi, Yazdan
    Akhavanallaf, Azadeh
    Shiri, Isaac
    Teixeira, Eliluane Pirazzo Andrade
    Hou, Xinchi
    Beauregard, Jean-Mathieu
    Rahmim, Arman
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (06) : 1516 - 1529