Enhanced honey badger optimization of performance analysis of evacuated tube heat pipe solar collector integrated with PCM storage unit

被引:1
|
作者
Ramesh, C. [1 ,5 ]
Vijayakumar, M. [2 ]
Kumaresan, G. [3 ]
Selvanayagam, Benjamin Franklin [4 ]
机构
[1] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[2] PSN Coll Engn & Technol, Dept Mech Engn, Tirunelveli, Tamil Nadu, India
[3] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam, Tamil Nadu, India
[4] Sri Ramakrishna Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[5] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore 641402, Tamil Nadu, India
关键词
Heat pipe; phase change material; aluminum fin; fin temperature; optimization; thermal energy storage; liquid fractions; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; WATER-HEATER; SYSTEM; TANK;
D O I
10.1177/0958305X231189187
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid method for improving the efficiency of heat pipe evacuated-tube solar-collector (HPETC) is proposed for incorporating the phase-change materials (PCMs) in both off-demand and regular operation. The proposed hybrid approach is called an improved honey badger algorithm (HBA). The crossover and mutation operator improves the honey badger's (HB) foraging habit. The proposed approach aims to generate hot air at various rates of airflow under incident and nonincident solar-radiation situations. The analysis is done on the effects of different energy-storage systems and the position of the heat pipe (HP). In a normal heat-pipe evacuated-tube solar collector, the HP is put within the glass tube that is closer to the upper-surface, and it is held in place through an aluminum fin. However, in the proposed method, the HP is rearranged in the tube's middle. In order to identify the PCM with the highest average-fin temperature, the temperatures of the area-weighted average-fin are measured and compared throughout the glass tubes under typical conditions. For maximizing the thermal-energy carrying capability, the average liquid fraction volume of PCMs is measured for a 24-h flow period. The average liquid-fraction volume of PCMs is continuously observed in stagnation mode till the glass tube reaches the maximal value. The structured mesh patch conforming method is used to invalidate the HPETC system's constituent parts, improving numerical stability and convergence. The proposed method efficiency is 0.43. The proposed method shows high efficiency compared with other existing methods.
引用
收藏
页数:28
相关论文
共 50 条
  • [41] Performance of a solar still integrated with evacuated tube collector in natural mode
    Singh, Ragh Vendra
    Kumar, Shiv
    Hasan, M. M.
    Khan, M. Emran
    Tiwari, G. N.
    DESALINATION, 2013, 318 : 25 - 33
  • [42] Theoretical and experimental studies of impacts of heat shields on heat pipe evacuated tube solar collector
    Huang, Xiaona
    Wang, Qiliang
    Yang, Honglun
    Zhong, Shuai
    Jiao, Dongsheng
    Zhang, Kaili
    Li, Mujun
    Pei, Gang
    RENEWABLE ENERGY, 2019, 138 : 999 - 1009
  • [43] Performance comparison of evacuated U-tube solar collector integrated parabolic reflector with conventional evacuated U-tube solar collector
    KIRAN NAIK, B.
    PREMNATH, S.
    MUTHUKUMAR, P.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2021, 46 (03):
  • [44] Experimental evaluation of a self storage integrated evacuated tube solar thermal collector
    Aramesh, Mohamad
    Shabani, Bahman
    JOURNAL OF ENERGY STORAGE, 2023, 62
  • [45] Performance comparison of evacuated U-tube solar collector integrated parabolic reflector with conventional evacuated U-tube solar collector
    B KIRAN NAIK
    S PREMNATH
    P MUTHUKUMAR
    Sādhanā, 2021, 46
  • [46] Experimental performance evaluation of a novel designed phase change material integrated manifold heat pipe evacuated tube solar collector system
    Chopra, K.
    Tyagi, V. V.
    Pathak, Atin K.
    Pandey, A. K.
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2019, 198
  • [47] Smart optimization of a thermosyphon heat pipe for an evacuated tube solar collector using response surface methodology (RSM)
    Sarafraz, M. M.
    Tlili, I.
    Tian, Zhe
    Bakouri, Mohsen
    Safaei, Mohammad Reza
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2019, 534
  • [48] Energetic and exergetic analysis of a heat pipe evacuated tube solar collector using MWCNT/water nanofluid
    Eltaweel, Mahmoud
    Abdel-Rehim, Ahmed A.
    Attia, Ahmed A. A.
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 22
  • [49] Numerical Analysis of Evacuated Tube Solar Collector with Heat Pipe Containing an I-section Insert
    Mthembu, Nokwanda
    Tartibu, Lagouge
    Mukuna, Jean Gad
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (03) : 3961 - 3976
  • [50] Optimization and thermal performance of evacuated tube solar collector with various nanofluids
    Yurddas, Ali
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 152