Numerical Analysis of Evacuated Tube Solar Collector with Heat Pipe Containing an I-section Insert

被引:2
|
作者
Mthembu, Nokwanda [1 ]
Tartibu, Lagouge [1 ]
Mukuna, Jean Gad [2 ]
机构
[1] Univ Johannesburg, Dept Mech & Ind Engn, Johannesburg, South Africa
[2] Mangosuthu Univ Technol, Dept Mech Engn, Durban, South Africa
关键词
Thermal resistance; Network model; Evacuated tube; Heat pipe solar collector; THERMAL PERFORMANCE; ENERGY;
D O I
10.1007/s13369-022-07348-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Evacuated tube collectors can achieve a much high efficiency and temperature for a much longer period compared to conventional single flat plate collector systems. However, they can be a lot more expensive compared to flat panel collectors. Hence, the building of a suitable model would make the analysis of the configuration of the systems more insightful to achieve higher efficiencies. In this paper, a thermal resistance network model of an evacuated tube heat pipe was developed. An analysis of its performance was done to understand the effect of adding an I-section geometry insert on the total thermal resistance, the heat transfer and the efficiency considering several working fluids such as water, ethanol, methanol, acetone and toluene. The proposed model was validated using data collected on a cloudy day from the SAURAN STATION located in UMLAZI, SOUTH AFRICA. This study reveals that the addition of an insert decreases the total thermal resistance, which results in improved efficiencies. Water exhibited higher efficiency compared to other working fluids with the efficiency of 62.24% and 54.27% corresponding to the configuration with and without a geometry insert. An improvement in the rate of heat transfer from 530 to 605 KW when introducing an insert into the heat pipe was observed. Interestingly, the solar collector exhibited better results, even on a cloudy day. The thermal resistance network model proposed in this paper was deemed appropriate to be used for the performance prediction of the heat pipe with an insert.
引用
收藏
页码:3961 / 3976
页数:16
相关论文
共 50 条
  • [1] Numerical Analysis of Evacuated Tube Solar Collector with Heat Pipe Containing an I-section Insert
    Nokwanda Mthembu
    Lagouge Tartibu
    Jean Gad Mukuna
    Arabian Journal for Science and Engineering, 2023, 48 : 3961 - 3976
  • [2] Design of Evacuated Tube Solar Collector with Heat Pipe
    Kumar, S. Siva
    Kumar, K. Mohan
    Kumar, S. R. Sanjeev
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (14) : 12641 - 12646
  • [3] Thermal Performance of Evacuated Tube Heat Pipe Solar Collector
    Putra, Nandy
    Kristian, M. R.
    David, R.
    Haliansyah, K.
    Ariantara, Bambang
    PROCEEDINGS OF THE 3RD AUN/SEED-NET REGIONAL CONFERENCE ON ENERGY ENGINEERING AND THE 7TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS (RCENE/THERMOFLUID 2015), 2016, 1737
  • [4] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [5] EVACUATED HEAT PIPE SOLAR COLLECTOR
    MAHDJURI, F
    ENERGY CONVERSION, 1979, 19 (02): : 85 - 90
  • [6] Evacuated tube solar heat pipe collector model and associated tests
    Jafarkazemi, Farzad
    Abdi, Hossein
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (02)
  • [7] Evacuated Heat Pipe Solar Collector.
    Mahdjuri, Faramarz
    Energie Alternative Habitat Territorio Energia, 1981, 3 (10): : 198 - 201
  • [8] Optical and thermal performance analysis of a compact solar collector with heat-pipe evacuated tube
    Yang, Moucun
    Zhi, Liming
    Diao, Kelong
    Zhu, Yuezhao
    Taylor, Robert A.
    SOLAR ENERGY, 2023, 258 : 118 - 129
  • [9] Experimental evaluation of the efficiency of a solar tube collector evacuated with and without heat pipe
    Eufracio Arias, Wilder Efrain
    Abregu Rodriguez, Nathaly Ibeth
    Rodriguez Espinoza, Dayana
    FUENTES EL REVENTON ENERGETICO, 2019, 17 (01): : 7 - 17
  • [10] Analysis of heat transfer characteristics for parabolic trough solar collector system with heat-pipe evacuated tube
    Zhang W.
    Wang J.
    Tian R.
    Xue Q.
    Ba X.
    2018, Chinese Society of Agricultural Engineering (34): : 202 - 209