Cutting Balloon Angioplasty for Severe In-Stent Restenosis after Carotid Artery Stenting: Long-Term Outcomes and Review of Literature

被引:0
|
作者
Lee, Jeong-Yoon [1 ,2 ]
Kim, Jonguk [1 ,2 ,3 ]
Kim, Do Yeon [4 ]
Kim, Jun Yup [4 ]
Baik, Sung Hyun [5 ]
Kang, Jihoon [4 ]
Kim, Beom Joon [4 ]
Bae, Hee-Joon [4 ]
Jung, Cheolkyu [5 ,6 ]
机构
[1] Soonchunhyang Univ, Seoul Hosp, Dept Neurol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Translat Med, Seoul, South Korea
[3] Inha Univ Hosp, Dept Neurol, Incheon, South Korea
[4] Seoul Natl Univ, Bundang Hosp, Dept Neurol, Seongnam, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Seongnam, South Korea
[6] Seoul Natl Univ, Bundang Hosp, Dept Radiol, 82 Gumi ro 173beon gil, Seongnam 13620, South Korea
关键词
Carotid artery stenosis; Balloon angioplasty; Endovascular procedure; Stent; RECURRENT STENOSIS; ENDARTERECTOMY; RISK; MANAGEMENT;
D O I
10.5469/neuroint.2024.00010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: Cutting balloon-percutaneous transluminal angioplasty (CB-PTA) is a feasible treatment option for in-stent restenosis (ISR) after carotid artery stenting (CAS). However, the longterm durability and safety of CB-PTA for ISR after CAS have not been well established. Materials and Methods: We retrospectively reviewed medical records of patients with ISR after CAS who had been treated with CB-PTA from 2012 to 2021 in our center. Detailed information of baseline characteristics, periprocedural and long-term outcomes, and follow-up imaging was collected. Results: During 2012-2021, a total of 301 patients underwent CAS. Of which, CB-PTA was performed on 20 lesions exhibiting severe ISR in 18 patients following CAS. No patient had any history of receiving carotid endarterectomy or radiation therapy. These lesions were located at the cervical segment of the internal carotid artery (n=16), proximal external carotid artery (n=1), and distal common carotid artery (n=1). The median time interval between initial CAS and detection of ISR was 390 days (interquartile range 324-666 days). The follow-up period ranged from 9 months to 9 years with a median value of 21 months. Four patients (22.2%) were symptomatic. The average of stenotic degree before and after the procedure was 79.2% and 34.7%, respectively. Out of the 18 patients receiving CB-PTA, 16 (88.9%) did not require additional stenting, and 16 (88.9%) did not experience recurrent ISR during the follow-up period. Two patients who experienced recurrent ISR were successfully treated with CB-PTA and additional stenting. No periprocedural complication was observed in any case. Conclusion: Regarding favorable periprocedural and long-term outcomes in our single-center experience, CB-PTA was a feasible and safe option for the treatment of severe ISR after CAS.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [31] Ultrasound criteria for severe in-stent restenosis following carotid artery stenting
    Zhou, Wei
    Felkai, Deborah D.
    Evans, Mark
    McCoy, Sally A.
    Lin, Peter H.
    Kougias, Panagiotos
    El-Sayed, Hosam F.
    Lumsden, Alan B.
    JOURNAL OF VASCULAR SURGERY, 2008, 47 (01) : 74 - 80
  • [32] Cutting balloon angioplasty versus balloon angioplasty for treating diffuse in-stent restenosis
    Spanos, V
    Sarais, C
    Toutouzas, K
    Moshiri, S
    Montorfano, M
    Briguori, C
    Stankovic, G
    Colombo, A
    EUROPEAN HEART JOURNAL, 2002, 23 : 553 - 553
  • [33] Use Of Drug-Eluting Balloon For The Treatment Of In-stent Restenosis After Carotid Artery Stenting
    Montorsi, Piero
    Bartorelli, Antonio
    Fabbiocchi, Franco
    Galli, Stefano
    Lualdi, Alessandro
    Ravagnani, Paolo
    Teruzzi, Giovanni
    Trabattoni, Daniela
    Troiano, Sarah
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B56 - B57
  • [34] Long-Term Risk of In-Stent Restenosis and Stent Fracture for Extracranial Vertebral Artery Stenting
    Li, Man Kwun Andrew
    Tsang, Anderson Chun On
    Tsang, Frederick Chun Pong
    Ho, Wai Shing
    Lee, Raymand
    Leung, Gilberto Ka Kit
    Lui, Wai Man
    CLINICAL NEURORADIOLOGY, 2019, 29 (04) : 701 - 706
  • [35] Long-Term Risk of In-Stent Restenosis and Stent Fracture for Extracranial Vertebral Artery Stenting
    Man Kwun Andrew Li
    Anderson Chun On Tsang
    Frederick Chun Pong Tsang
    Wai Shing Ho
    Raymand Lee
    Gilberto Ka Kit Leung
    Wai Man Lui
    Clinical Neuroradiology, 2019, 29 : 701 - 706
  • [36] Long-term Results of Drug-Eluting Balloon Angioplasty for Treatment of Refractory Recurrent Carotid In-Stent Restenosis
    Gandini, Roberto
    Del Giudice, Costantino
    Da Ros, Valerio
    Sallustio, Fabrizio
    Altobelli, Simone
    D'Onofrio, Adolfo
    Abrignani, Sergio
    Vasili, Erald
    Stanzione, Paolo
    Simonetti, Giovanni
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (05) : 671 - 677
  • [37] Balloon Angioplasty for In-Stent Stenosis After Carotid Artery Stenting Is Associated With an Increase in Repeat Interventions
    Donas, Konstantinos P.
    Eisenack, Markus
    Torsello, Giovanni
    JOURNAL OF ENDOVASCULAR THERAPY, 2011, 18 (05) : 720 - 725
  • [38] Regarding "Patterns of in-stent restenosis after carotid artery stenting: Classification and implications for long term outcome" - Reply
    Lal, Brajesh K.
    JOURNAL OF VASCULAR SURGERY, 2008, 47 (06) : 1380 - 1380
  • [39] In-stent restenosis after carotid angioplasty-stenting: Incidence and management - Discussion
    Sullivan, TM
    Hobson, RW
    Burnand, KG
    Turnipseed, WD
    Andros, G
    JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) : 225 - 226
  • [40] Drug-Eluting Balloon Angioplasty for In-Stent Restenosis Following Carotid Artery Stent Placement
    Bhatia, Kunal
    Akhtar, Iqra N.
    Akinci, Yasemin
    Liaqat, Jahanzeb
    Siddiq, Farhan
    Gomez, Camilo R.
    Qureshi, Adnan I.
    JOURNAL OF NEUROIMAGING, 2020, 30 (03) : 267 - 275