Modelling the impact of building energy consumption on urban thermal environment: The bias of the inventory approach

被引:0
|
作者
Chen, Liutao [1 ,2 ]
Yang, Jiachuan [1 ,2 ]
Zheng, Xing [3 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[2] HKUST Fok Ying Tung Res Inst, Guangzhou, Peoples R China
[3] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Inventory approach; Building energy modelling; Building energy consumption; Building waste heat emissions; Urban canopy model; Urban heat island; Surface energy balance; ANTHROPOGENIC HEAT EMISSIONS; CLIMATE; SURFACE; CANOPY; METHODOLOGY; DISCHARGES; MITIGATION; ISLANDS; SYSTEM; CITIES;
D O I
10.1016/j.uclim.2023.101802
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building waste heat is the dominant contributor to anthropogenic heat that causes the urban heat island effect. Numerous studies have estimated the impact of anthropogenic heat emissions on the urban environment using the inventory (IVT) approach, but the assumptions of this method equating building energy consumption to anthropogenic sensible heat emissions, can lead to over/underestimation of air and surface temperatures in the urban canyon. The building energy modelling (BEM) approach, considering the dynamic interaction between the outdoor microclimate and indoor environment, provides a reliable way to quantify the impact of building waste heat on urban climate. However, the temperature bias caused by the inventory approach has not been systematically investigated in the literature. In this study, we conduct simulations in Beijing for three building types (residential, office, and hotel) in four months (January, April, July, and October) to reveal the temperature biases by the IVT approach using the results from the BEM approach as the ground truth. Results show that the IVT approach overestimates the canyon air temperature (T-can) in heating and ventilation months. The positive bias of daily maximum Tcan is >1C in January and 2C in October. In the summertime, the temperature bias by the IVT approach varies with the type and location of air conditioning (A/C). Daily mean T-can is underestimated by up to 1.2 degrees C when using window-type A/C, and is overestimated by up to 2.1 degrees C when using water-cooled A/C at rooftop. The temperature bias is more evident in compact neighbourhoods with higher building surface fractions. Furthermore, it is found that the IVT approach causes overestimation of sensible heat flux and underestimation of latent heat flux in most of the studied scenarios, indicating a possible overestimation of urban heat/dry island in previous studies using the IVT approach. This study offers important insights into the buildingmicroclimate feedback in the urban environment.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] IMPACT OF BUILDING FORM AND URBAN MICROCLIMATE ON ENERGY CONSUMPTION OF RESIDENTIAL BUILDINGS
    Kokhalou, Elnaz Mehrvar
    Haghi, Mehri Fadaei
    INTERNATIONAL JOURNAL OF ECOSYSTEMS AND ECOLOGY SCIENCE-IJEES, 2018, 8 (02): : 241 - 248
  • [22] Impact of Urban Morphology on Infiltration-Induced Building Energy Consumption
    Jurelionis, Andrius
    Bouris, Demetri G.
    ENERGIES, 2016, 9 (03)
  • [23] Field measurements of urban residential energy consumption and thermal environment in China
    Jiang, Zhongtian
    Yoshino, Hiroshi
    Li, Zhenhai
    Li, Nianping
    Liu, Jing
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 285 - 292
  • [24] FIELD MEASUREMENTS OF URBAN RESIDENTIAL ENERGY CONSUMPTION AND THERMAL ENVIRONMENT IN CHINA
    Zhou, Jie
    Yoshino, Hiroshi
    Li, Zhenhai
    Li, Nianping
    Liu, Jing
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 629 - 635
  • [25] On the accuracy of Urban Building Energy Modelling
    Oraiopoulos, A.
    Howard, B.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 158
  • [26] Survey on Energy Consumption and Indoor Thermal Environment of University Building in Changsha, China
    Tian, Peizhe
    Zhou, Hui
    Li, Nianping
    Su, Qie
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 65 - 71
  • [27] Analysis on Building Thermal Environment and Energy Consumption for an Apartment in the Different Heating Modes
    Hu, Wenju
    Liu, Qin
    Nie, Jin-zhe
    Chang, Mo-ning
    Gao, Yan
    Zhang, Qun-li
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2545 - 2552
  • [28] Energy consumption pattern and indoor thermal environment of residential building in rural China
    Li, Baiyi
    You, Liyao
    Zheng, Min
    Wang, Yao
    Wang, Ziguang
    Energy and Built Environment, 2020, 1 (03): : 327 - 336
  • [29] Urban and future climate - Impact on energy consumption and thermal comfort of buildings
    Remund, Jan
    Grossenbacher, Urs
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4738 - 4745
  • [30] Impact of urban form on building energy consumption in different climate zones of China
    Zhao, Yiman
    Ding, Xiaotian
    Wu, Ziyu
    Yin, Shi
    Fan, Yifan
    Ge, Jian
    ENERGY AND BUILDINGS, 2024, 320