Modelling the impact of building energy consumption on urban thermal environment: The bias of the inventory approach

被引:0
|
作者
Chen, Liutao [1 ,2 ]
Yang, Jiachuan [1 ,2 ]
Zheng, Xing [3 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[2] HKUST Fok Ying Tung Res Inst, Guangzhou, Peoples R China
[3] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Inventory approach; Building energy modelling; Building energy consumption; Building waste heat emissions; Urban canopy model; Urban heat island; Surface energy balance; ANTHROPOGENIC HEAT EMISSIONS; CLIMATE; SURFACE; CANOPY; METHODOLOGY; DISCHARGES; MITIGATION; ISLANDS; SYSTEM; CITIES;
D O I
10.1016/j.uclim.2023.101802
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building waste heat is the dominant contributor to anthropogenic heat that causes the urban heat island effect. Numerous studies have estimated the impact of anthropogenic heat emissions on the urban environment using the inventory (IVT) approach, but the assumptions of this method equating building energy consumption to anthropogenic sensible heat emissions, can lead to over/underestimation of air and surface temperatures in the urban canyon. The building energy modelling (BEM) approach, considering the dynamic interaction between the outdoor microclimate and indoor environment, provides a reliable way to quantify the impact of building waste heat on urban climate. However, the temperature bias caused by the inventory approach has not been systematically investigated in the literature. In this study, we conduct simulations in Beijing for three building types (residential, office, and hotel) in four months (January, April, July, and October) to reveal the temperature biases by the IVT approach using the results from the BEM approach as the ground truth. Results show that the IVT approach overestimates the canyon air temperature (T-can) in heating and ventilation months. The positive bias of daily maximum Tcan is >1C in January and 2C in October. In the summertime, the temperature bias by the IVT approach varies with the type and location of air conditioning (A/C). Daily mean T-can is underestimated by up to 1.2 degrees C when using window-type A/C, and is overestimated by up to 2.1 degrees C when using water-cooled A/C at rooftop. The temperature bias is more evident in compact neighbourhoods with higher building surface fractions. Furthermore, it is found that the IVT approach causes overestimation of sensible heat flux and underestimation of latent heat flux in most of the studied scenarios, indicating a possible overestimation of urban heat/dry island in previous studies using the IVT approach. This study offers important insights into the buildingmicroclimate feedback in the urban environment.
引用
收藏
页数:24
相关论文
共 50 条
  • [11] Quantifying the impact of urban wind sheltering on the building energy consumption
    Nikkho, Saber Khoshdel
    Heidarinejad, Mohammad
    Liu, Jiying
    Srebric, Jelena
    APPLIED THERMAL ENGINEERING, 2017, 116 : 850 - 865
  • [12] Evaluation of the impact of the surrounding urban morphology on building energy consumption
    Wong, Nyuk Hien
    Jusuf, Steve Kardinal
    Syafii, Nedyomukti Imam
    Chen, Yixing
    Hajadi, Norwin
    Sathyanarayanan, Haripriya
    Manickavasagam, Yamini Vidya
    SOLAR ENERGY, 2011, 85 (01) : 57 - 71
  • [13] Impact of building greening on building energy consumption: A quantitative computational approach
    Qiao, Renlu
    Liu, Tongtong
    JOURNAL OF CLEANER PRODUCTION, 2020, 246 (246)
  • [14] The Impact of the Thermal Comfort Models on the Prediction of Building Energy Consumption
    Albatayneh, Aiman
    Alterman, Dariusz
    Page, Adrian
    Moghtaderi, Behdad
    SUSTAINABILITY, 2018, 10 (10)
  • [15] Investigation and analysis on civil building energy consumption and thermal environment in Changsha
    Yang, CZ
    Wu, XY
    Li, WJ
    Dai, XL
    Li, NP
    Dai, XZ
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3938 - 3942
  • [16] The Impact of Detail, Shadowing and Thermal Zoning Levels on Urban Building Energy Modelling (UBEM) on a District Scale
    Faure, Xavier
    Johansson, Tim
    Pasichnyi, Oleksii
    ENERGIES, 2022, 15 (04)
  • [17] Impact of urban wind environment on urban building energy: A review of mechanisms and modeling
    Jie, Pengyu
    Su, Meifang
    Gao, Naiping
    Ye, Yu
    Kuang, Xiaoming
    Chen, Jun
    Li, Peixian
    Grunewald, John
    Xie, Xiaoping
    Shi, Xing
    BUILDING AND ENVIRONMENT, 2023, 245
  • [18] Modelling Building Stock Energy Consumption at the Urban Level from an Empirical Study
    Ji, Qunfeng
    Bi, Yangbo
    Makvandi, Mehdi
    Deng, Qinli
    Zhou, Xilin
    Li, Chuancheng
    BUILDINGS, 2022, 12 (03)
  • [19] Urban climate - Impact on energy consumption and thermal comfort of buildings
    Remund, Jan
    Grossenbacher, Urs
    PROCEEDINGS OF THE ISES EUROSUN 2018 CONFERENCE - 12TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2018, : 1614 - 1623
  • [20] A Review: Urban Heat Island and its Impact on Building Energy Consumption
    Maghrabi, Ammar
    Mohamed, Mohd Farid
    Raman, Sudharshan N.
    Sulaiman, Mohd Khairul Azhar Mat
    Yusoff, Wardah Fatimah Mohammad
    Abuhussain, Mohammed Awad
    JURNAL KEJURUTERAAN, 2022, 34 (04): : 553 - 563