Guided block matching and 4-D transform domain filter projection denoising method for dynamic PET image reconstruction

被引:2
|
作者
Xin, Lin [1 ]
Zhuo, Weihai [1 ]
Liu, Haikuan [1 ]
Xie, Tianwu [1 ]
机构
[1] Fudan Univ, Inst Radiat Med, 2094 Xietu Rd, Shanghai 200032, Peoples R China
关键词
Block matching and 4-D transform domain filter; Dynamic PET; Projection denoising; POSITRON-EMISSION-TOMOGRAPHY; WHOLE-BODY PET;
D O I
10.1186/s40658-023-00580-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDynamic PET is an essential tool in oncology due to its ability to visualize and quantify radiotracer uptake, which has the potential to improve imaging quality. However, image noise caused by a low photon count in dynamic PET is more significant than in static PET. This study aims to develop a novel denoising method, namely the Guided Block Matching and 4-D Transform Domain Filter (GBM4D) projection, to enhance dynamic PET image reconstruction.MethodsThe sinogram was first transformed using the Anscombe method, then denoised using a combination of hard thresholding and Wiener filtering. Each denoising step involved guided block matching and grouping, collaborative filtering, and weighted averaging. The guided block matching was performed on accumulated PET sinograms to prevent mismatching due to low photon counts. The performance of the proposed denoising method (GBM4D) was compared to other methods such as wavelet, total variation, non-local means, and BM3D using computer simulations on the Shepp-Logan and digital brain phantoms. The denoising methods were also applied to real patient data for evaluation.ResultsIn all phantom studies, GBM4D outperformed other denoising methods in all time frames based on the structural similarity and peak signal-to-noise ratio. Moreover, GBM4D yielded the lowest root mean square error in the time-activity curve of all tissues and produced the highest image quality when applied to real patient data.ConclusionGBM4D demonstrates excellent denoising and edge-preserving capabilities, as validated through qualitative and quantitative assessments of both temporal and spatial denoising performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Image speckle noise denoising by a multi-layer fusion enhancement method based on block matching and 3D filtering
    Huang, Shuo
    Zhou, Ping
    Shi, Hao
    Sun, Yu
    Wan, Suiren
    IMAGING SCIENCE JOURNAL, 2019, 67 (04): : 224 - 235
  • [42] An algorithm for direct 4-D PET image reconstruction/non-rigid motion estimation with limited MRI prior information
    Bousse, Alexandre
    Jiao, Jieqing
    Pizarro, Luis
    Thielemans, Kris
    Atkinson, David
    Ourselin, Sebastien
    Arridge, Simon
    Hutton, Brian F.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [43] Four-dimensional (4D) image reconstruction strategies in dynamic PET: Beyond conventional independent frame reconstruction
    Rahmim, Arman
    Tang, Jing
    Zaidi, Habib
    MEDICAL PHYSICS, 2009, 36 (08) : 3654 - 3670
  • [44] Evaluation of a 4D PET image reconstruction method with respiratory motion compensation in a patient study
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [45] Anatomy-assisted direct 4D parametric image reconstruction for dynamic cardiac PET imaging
    Deng, Wei
    Wang, Xinhui
    Tang, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [46] 4D deep image prior: dynamic PET image denoising using an unsupervised four-dimensional branch convolutional neural network
    Hashimoto, Fumio
    Ohba, Hiroyuki
    Ote, Kibo
    Kakimoto, Akihiro
    Tsukada, Hideo
    Ouchi, Yasuomi
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (01):
  • [47] Evaluation of a new 4D PET image reconstruction method with respiratory motion compensation in a CHO study
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [48] 4D PET with the quad-HIDAC: Development of dynamic list-mode EM image reconstruction
    Walledge, RJ
    Reader, AJ
    Aboagye, EO
    Spinks, TJ
    Honer, M
    Missimer, J
    Jeavons, AP
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1716 - 1720
  • [49] Impact of time-of-flight on indirect 3D and direct 4D parametric image reconstruction in the presence of inconsistent dynamic PET data
    Kotasidis, F. A.
    Mehranian, A.
    Zaidi, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3443 - 3471
  • [50] 3D/4D hybrid spectral domain synthetic aperture image reconstruction method for hand-held ultrasound systems
    Tasinkevych, Yuriy
    Lewandowski, Marcin
    Walczak, Mateusz
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2358 - 2361