Impact of time-of-flight on indirect 3D and direct 4D parametric image reconstruction in the presence of inconsistent dynamic PET data

被引:6
|
作者
Kotasidis, F. A. [1 ,2 ]
Mehranian, A. [1 ]
Zaidi, H. [1 ,3 ,4 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Manchester, Wolfson Mol Imaging Ctr, MAHSC, Manchester M20 3LJ, Lancs, England
[3] Univ Geneva, Geneva Neurosci Ctr, CH-1205 Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
基金
瑞士国家科学基金会;
关键词
PET; time-of-flight; direct 4D reconstruction; parametric imaging; POSITRON-EMISSION-TOMOGRAPHY; MOTION CORRECTION; TOF PET; ATTENUATION CORRECTION; INPUT FUNCTIONS; RESOLUTION; BODY; COMPENSATION; REDUCTION; ALGORITHM;
D O I
10.1088/0031-9155/61/9/3443
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kinetic parameter estimation in dynamic PET suffers from reduced accuracy and precision when parametric maps are estimated using kinetic modelling following image reconstruction of the dynamic data. Direct approaches to parameter estimation attempt to directly estimate the kinetic parameters from the measured dynamic data within a unified framework. Such image reconstruction methods have been shown to generate parametric maps of improved precision and accuracy in dynamic PET. However, due to the interleaving between the tomographic and kinetic modelling steps, any tomographic or kinetic modelling errors in certain regions or frames, tend to spatially or temporally propagate. This results in biased kinetic parameters and thus limits the benefits of such direct methods. Kinetic modelling errors originate from the inability to construct a common single kinetic model for the entire field-of-view, and such errors in erroneously modelled regions could spatially propagate. Adaptive models have been used within 4D image reconstruction to mitigate the problem, though they are complex and difficult to optimize. Tomographic errors in dynamic imaging on the other hand, can originate from involuntary patient motion between dynamic frames, as well as from emission/transmission mismatch. Motion correction schemes can be used, however, if residual errors exist or motion correction is not included in the study protocol, errors in the affected dynamic frames could potentially propagate either temporally, to other frames during the kinetic modelling step or spatially, during the tomographic step. In this work, we demonstrate a new strategy to minimize such error propagation in direct 4D image reconstruction, focusing on the tomographic step rather than the kinetic modelling step, by incorporating time-of-flight (TOF) within a direct 4D reconstruction framework. Using ever improving TOF resolutions (580 ps, 440 ps, 300 ps and 160 ps), we demonstrate that direct 4D TOF image reconstruction can substantially prevent kinetic parameter error propagation either from erroneous kinetic modelling, inter-frame motion or emission/transmission mismatch. Furthermore, we demonstrate the benefits of TOF in parameter estimation when conventional post-reconstruction (3D) methods are used and compare the potential improvements to direct 4D methods. Further improvements could possibly be achieved in the future by combining TOF direct 4D image reconstruction with adaptive kinetic models and interframe motion correction schemes.
引用
收藏
页码:3443 / 3471
页数:29
相关论文
共 50 条
  • [1] Error Propagation Reduction in Direct 4D Image Reconstruction Using Time-Of-Flight PET
    Kotasidis, Fotis A.
    Mehranian, Abolfazl
    Zaidi, Habib
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [2] Direct 4D parametric image reconstruction for dynamic cardiac PET imaging
    Tang, Jing
    Bengel, Frank
    Zhou, Yun
    Bravo, Paco
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] Impact of Time-Of-Flight Image Reconstruction in PET Parametric Imaging
    Kotasidis, Fotis A.
    Mehranian, Abolfazl
    Zaidi, Habib
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [4] Analytic Reconstruction of the Attenuation from 3D Time-of-Flight PET Data
    Rezaei, Ahmadreza
    Nuyts, Johan
    Defrise, Michel
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2330 - 2333
  • [5] Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET
    Watson, Charles C.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1736 - 1739
  • [6] Initial evaluation of a direct 4D PET parametric image reconstruction method
    Yan, Jianhua
    Planeta-Wilson, Beata
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [7] Anatomy-assisted direct 4D parametric image reconstruction for dynamic cardiac PET imaging
    Deng, Wei
    Wang, Xinhui
    Tang, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [8] Initial Evaluation of Direct 4D Parametric Reconstruction with Human PET Data
    Yan, Jianhua
    Planeta-Wilson, Beata
    Gallezot, Jean-Dominique
    Carson, Richard E.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2503 - 2506
  • [9] Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing
    Vandenberghe, S
    Daube-Witherspoon, ME
    Lewitt, RM
    Karp, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1603 - 1621
  • [10] Evaluation of Direct 4D Parametric Reconstruction with Low Count Human PET Data
    Yan, Jianhua
    Planeta-Wilson, Beata
    Gallezot, Jean-Dominique
    Carson, Richard E.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2259 - 2262