Impact of time-of-flight on indirect 3D and direct 4D parametric image reconstruction in the presence of inconsistent dynamic PET data

被引:6
|
作者
Kotasidis, F. A. [1 ,2 ]
Mehranian, A. [1 ]
Zaidi, H. [1 ,3 ,4 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Manchester, Wolfson Mol Imaging Ctr, MAHSC, Manchester M20 3LJ, Lancs, England
[3] Univ Geneva, Geneva Neurosci Ctr, CH-1205 Geneva, Switzerland
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
基金
瑞士国家科学基金会;
关键词
PET; time-of-flight; direct 4D reconstruction; parametric imaging; POSITRON-EMISSION-TOMOGRAPHY; MOTION CORRECTION; TOF PET; ATTENUATION CORRECTION; INPUT FUNCTIONS; RESOLUTION; BODY; COMPENSATION; REDUCTION; ALGORITHM;
D O I
10.1088/0031-9155/61/9/3443
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Kinetic parameter estimation in dynamic PET suffers from reduced accuracy and precision when parametric maps are estimated using kinetic modelling following image reconstruction of the dynamic data. Direct approaches to parameter estimation attempt to directly estimate the kinetic parameters from the measured dynamic data within a unified framework. Such image reconstruction methods have been shown to generate parametric maps of improved precision and accuracy in dynamic PET. However, due to the interleaving between the tomographic and kinetic modelling steps, any tomographic or kinetic modelling errors in certain regions or frames, tend to spatially or temporally propagate. This results in biased kinetic parameters and thus limits the benefits of such direct methods. Kinetic modelling errors originate from the inability to construct a common single kinetic model for the entire field-of-view, and such errors in erroneously modelled regions could spatially propagate. Adaptive models have been used within 4D image reconstruction to mitigate the problem, though they are complex and difficult to optimize. Tomographic errors in dynamic imaging on the other hand, can originate from involuntary patient motion between dynamic frames, as well as from emission/transmission mismatch. Motion correction schemes can be used, however, if residual errors exist or motion correction is not included in the study protocol, errors in the affected dynamic frames could potentially propagate either temporally, to other frames during the kinetic modelling step or spatially, during the tomographic step. In this work, we demonstrate a new strategy to minimize such error propagation in direct 4D image reconstruction, focusing on the tomographic step rather than the kinetic modelling step, by incorporating time-of-flight (TOF) within a direct 4D reconstruction framework. Using ever improving TOF resolutions (580 ps, 440 ps, 300 ps and 160 ps), we demonstrate that direct 4D TOF image reconstruction can substantially prevent kinetic parameter error propagation either from erroneous kinetic modelling, inter-frame motion or emission/transmission mismatch. Furthermore, we demonstrate the benefits of TOF in parameter estimation when conventional post-reconstruction (3D) methods are used and compare the potential improvements to direct 4D methods. Further improvements could possibly be achieved in the future by combining TOF direct 4D image reconstruction with adaptive kinetic models and interframe motion correction schemes.
引用
收藏
页码:3443 / 3471
页数:29
相关论文
共 50 条
  • [21] Dependence of 3D/4D PET Quantitative Image Features On Noise
    Oliver, J.
    Budzevich, M.
    Zhang, G.
    Latifi, K.
    Dilling, T.
    Balagurunathan, Y.
    Gu, Y.
    Grove, O.
    Feygelman, V.
    Gillies, R.
    Moros, E.
    Lee, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 380 - 380
  • [22] 3D Reconstruction With Time-of-Flight Depth Camera and Multiple Mirrors
    Trong-Nguyen Nguyen
    Huu-Hung Huynh
    Meunier, Jean
    IEEE ACCESS, 2018, 6 : 38106 - 38114
  • [23] 3D indirect time-of-flight imaging employing transmission electroabsorption modulators
    Miller, Markus
    Sassiya, Bedouin
    Menzel, Susanne
    Ebeling, Karl-Joachim
    Michalzik, Rainer
    UNCONVENTIONAL OPTICAL IMAGING III, 2022, 12136
  • [24] Fast iterative image reconstruction of 3D PET data
    Kinahan, PE
    Michel, C
    Defrise, M
    Townsend, DW
    Sibomana, M
    Lonneux, M
    Newport, DF
    Luketich, JD
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1918 - 1922
  • [25] Evaluation of Respiratory Motion Impact on 3D and 4D PET Imaging
    Cui, Y.
    Bowsher, J.
    Cai, J.
    Yin, F. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E553 - E553
  • [26] Comparison of four dynamic filtering techniques in the reconstruction of 4D PET data
    Delaplace, Rudy
    Jullian, Yann
    Laporte, Pierre
    Stute, Simon
    Tauber, Clovis
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [27] Diffuse Mirrors: 3D Reconstruction from Diffuse Indirect Illumination Using Inexpensive Time-of-Flight Sensors
    Heide, Felix
    Xiao, Lei
    Heidrich, Wolfgang
    Hullin, Matthias B.
    2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 3222 - 3229
  • [28] Impact of Erroneous Kinetic Model Formulation in Direct 4D Image Reconstruction
    Kotasidis, Fotis A.
    Matthews, Julian C.
    Angelis, Georgios I.
    Markiewicz, Pawel J.
    Lionheart, William R.
    Reader, Andrew J.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2366 - +
  • [29] Estimation of Gap Data Using Bow-Tie Filters for 3D Time-of-Flight PET
    Ren, Ran
    Li, Quanzheng
    Ahn, Sangtae
    Cho, Sanghee
    Leahy, Richard M.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2691 - 2694
  • [30] Data processing method of time-of-flight 3D imaging camera
    Pan H.-D.
    Wang Q.-C.
    Xie B.
    Xu S.-F.
    Liu J.-L.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (06): : 1049 - 1056