Power consumption of model houses with and without PCM plaster lining using different heating methods

被引:5
|
作者
Nemeth, Bence [1 ]
Ujhidy, Aurel [1 ]
Toth, Judit [1 ]
Ferencz, Monika [1 ,2 ]
Kurdi, Robert [2 ]
Gyenis, Janos [1 ]
Feczko, Tivadar [1 ,2 ]
机构
[1] Res Ctr Nat Sci, Inst Mat & Environm Chem, Magyar tudosok korutja 2, H-1117 Budapest, Hungary
[2] Univ Pannonia, Fac Engn, Egyet u 10, H-8200 Veszprem, Hungary
关键词
Thermal energy storage; Phase change material; Microencapsulation; Building envelope; Heating efficiency; PHASE-CHANGE MATERIALS; THERMAL PERFORMANCE; STORAGE TANK; PUMP SYSTEM; ENERGY; PARAMETERS; REDUCTION; DEMAND; DESIGN; GYPSUM;
D O I
10.1016/j.enbuild.2023.112845
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal behaviour and power demand of two container model houses were studied. One of them was equipped with plaster lining with incorporated PCM microcapsules, and the second one served as refer-ence during two successive winter periods. In the first winter period of 2019/20, an electric radiator was applied for heating the houses during the daytime, and then they were let cool down from evening to the next morning. The dynamic thermal behaviour and power demand of the model houses were investi-gated during the heating up periods, then in a quasi-thermal equilibrium, as well as along their sponta-neous cooling down process at changing environmental temperatures. The indoor and environmental air temperatures, internal and external wall surface temperatures were collected by data logger during the whole winter periods for both model houses. Through the second winter period of 2020/21 the same methodology was used; nevertheless, the model houses were heated by air-air heat pumps. The perfor-mance coefficient (COP) of heat pumps was compared to the electric radiators. The estimated COP showed significant correlation with the temperature differences between the outdoor and indoor air tem-peratures, considerable worsening from COP = 3.1-3.4 to COP = 2.0-2.1 with increasing temperature drop to be overcome by the applied air-air heat pumps. However, there was no considerable dependence observed between the reference and PCM plaster lined houses. Equations were suggested to estimate the power demand in quasi-thermal equilibrium for both model houses and both heating methods as a function of the temperature differences between indoor and outdoor air. The power demand of PCM plaster lined model house compared to the reference house was lower by 10.3 % and 7.0 % using electric radiators or heat pumps, respectively, throughout the whole winter period, considering a medium tem-perature drop of 20 degrees C through the walls.(c) 2023 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A Sensor Predictive Model for Power Consumption using Machine Learning
    Moocheet, Nalveer
    Jaumard, Brigitte
    Thibault, Pierre
    Eleftheriadis, Lackis
    2023 IEEE 12TH INTERNATIONAL CONFERENCE ON CLOUD NETWORKING, CLOUDNET, 2023, : 238 - 246
  • [22] A Predictive Model for Power Consumption Estimation Using Machine Learning
    Aboubakar, Moussa
    Quenel, Ilhem
    Ari, Ado Adamou Abba
    INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ENERGY TECHNOLOGIES (ICECET 2021), 2021, : 61 - 65
  • [23] Power Consumption Contrasting Model for Different Logarithmic Active Pixel Sensor Topologies
    de Oliveira, Ewerton Gomes
    de Moraes Cruz, Carlos Augusto
    de Lima Monteiro, Davies William
    2017 2ND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SYSTEMS, CIRCUITS AND TRANSDUCERS (INSCIT), 2017, : 69 - 73
  • [24] Analysis of a large power PMSM using different control methods
    Zhao, XT
    Li, CJ
    Li, YH
    Wang, CS
    ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, : 416 - 421
  • [25] Probabilistic Neuromorphic System Using Binary Phase-Change Memory (PCM) Synapses: Detailed Power Consumption Analysis
    Garbin, Daniele
    Suri, Manan
    Bichler, Olivier
    Querlioz, Damien
    Gamrat, Christian
    DeSalvo, Barbara
    2013 13TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2013, : 91 - 94
  • [26] The design of Viterbi decoder for low power consumption space time trellis code without adder architecture using RTL model
    Abu, Mohd Azlan
    Harun, Harlisya
    Harmin, Mohammad Yazdi
    Wahab, Noor Izzri Abdul
    Kadir, Muhd Khairulzaman Abdul
    WORLD JOURNAL OF ENGINEERING, 2016, 13 (06) : 540 - 546
  • [27] Evaluation of different methods to ameliorate the performance of PV/T systems using hybrid nanofluids and PCM in a spiral tube with different cross sections
    Jasim, Dheyaa J.
    Al-Asadi, Hasan A.
    Alizadeh, Asad
    Nabi, Hossein
    Albayati, Talib M.
    Salih, Issam K.
    Pasha, Pooya
    Ganji, Davood Domiri
    RESULTS IN ENGINEERING, 2023, 20
  • [28] Comparison of vacuum drying characteristics of radiata pine timber using different heating methods
    Jung, HS
    Eom, CD
    So, BJ
    DRYING TECHNOLOGY, 2004, 22 (05) : 1005 - 1022
  • [29] Methods of Using Different Liquid Fuels for Heating Open-Hearth Furnaces.
    Oleksiak, Roman
    Roslon, Sylwester
    Hutnik Warszawa, 1986, 53 (03): : 80 - 81
  • [30] Power consumption forecast model using ensemble learning for smart grid
    Jatinder Kumar
    Rishabh Gupta
    Deepika Saxena
    Ashutosh Kumar Singh
    The Journal of Supercomputing, 2023, 79 : 11007 - 11028