Repair of fire-damaged RC square columns with CFRP textile-reinforced ECC matrix

被引:16
|
作者
Liu, Wang-Wei [1 ,2 ]
Ouyang, Li-Jun [3 ]
Gao, Wan-Yang [1 ,2 ]
Liang, Jian [1 ,2 ]
Wang, Tian-Ci [1 ,2 ]
Song, Jiang [1 ,2 ]
Yang, Jian [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai Key Lab Digital Maintenance Bldg & Infras, Shanghai 200240, Peoples R China
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
RC columns; Fire damage; Strengthening; ECC; Textile; Axial compressive behavior; ENGINEERED CEMENTITIOUS COMPOSITE; CONCRETE COLUMNS; FRP CONFINEMENT; BEAMS; BEHAVIOR; BASALT; CAPACITY; MORTAR; STRAIN; MODEL;
D O I
10.1016/j.engstruct.2023.116530
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber-reinforced polymer (FRP) textile reinforced engineered cementitious composite (ECC) matrix (TRE for short) is a newly developed composite system with great potential for the strengthening and life extension of damaged reinforced concrete (RC) columns after fire exposure. It combines the advantages of the lightweight and high strength of FRP textile and the ultra-high ductility of ECC material. However, there is a lack of research on the use of the TRE system to strengthen fire-damaged RC columns. This paper presents an experimental study on the axial compressive behavior of fire-damaged square RC columns strengthened with the TRE system. A total of 13 specimens were prepared and tested under axial compression. The test variables included the fire-exposure time (2 h or 3 h) used to produce the initial pre-damage of RC columns, the type of cementitious matrix (ECC or mortar), the number of TRE layers (2 layers or 3 layers), and the thickness of the concrete cover (20 mm or 40 mm). The failure modes, load capacity, secant stiffness, ultimate displacement, load-displacement curves of the specimens and the hoop tensile strains in the outermost layer of the CFRP textiles were investigated and discussed. The typical failure mode of the strengthened specimens was characterized by tensile rupture of the fiber rovings bridging the main crack in the strengthening jacket. The results showed that the use of the TRE system could significantly increase the load capacity, secant stiffness and ultimate displacement of fire-damaged RC columns. Depending on the design parameters, the enhancement percentages in the load capacity varied between 18% and 126%.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Strengthening pre-damaged RC square columns with fabric-reinforced cementitious matrix (FRCM): Experimental investigation
    Alhoubi, Yazan
    El Refai, Ahmed
    Abed, Farid
    El-Maaddawy, Tamer
    Tello, Noor
    COMPOSITE STRUCTURES, 2022, 294
  • [42] Seismic behaviour of RC columns retrofitted with textile-reinforced mortar (TRM) optimized by short PVA fibres
    Guo, Liying
    Deng, Mingke
    Li, Tong
    STRUCTURES, 2023, 50 : 244 - 254
  • [43] Seismic Behavior of RC Columns Strengthened with Textile-Reinforced Ultrahigh-Toughness Cementitious Composite Jackets
    Hou, Lijun
    Xu, Ran
    Yu, Xiaotong
    Liu, Zikai
    Liu, Gengsheng
    Chen, Da
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2024, 28 (05)
  • [44] Strengthening and repair of deficient reinforced concrete columns using textile-reinforced mortar: State-of-the-art review
    Kobbekaduwa, Dhanushka
    Nanayakkara, Ominda
    Di Sarno, Luigi
    Krevaikas, Theofanis
    STRUCTURES, 2024, 65
  • [45] Effect of size on the eccentric compression performance of damaged square RC columns strengthened with CFRP: An experimental study
    Si, Jianhui
    Li, Kai
    Zeng, Zhaobao
    Liu, Zewei
    Hu, Jiannan
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (01) : 168 - 182
  • [46] Experimental study on pre-damaged RC beams shear-strengthened with textile-reinforced mortar (TRM)
    Guo, Liying
    Deng, Mingke
    Chen, Hui
    Li, Ruizhe
    Ma, Xiangkun
    Zhang, Yangxi
    ENGINEERING STRUCTURES, 2022, 256
  • [47] Cyclic performance of fire-damaged concrete-filled steel tubular beam-columns repaired with CFRP wraps
    Tao, Zhong
    Han, Lin-Hai
    Zhuang, Jin-Ping
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (01) : 37 - 50
  • [48] Experimental investigation of high strength reinforced concrete columns damaged by fire and retrofitted with CFRP jackets
    Xu, J.
    Tan, C.
    Aboutaha, R.
    5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, 2019, 358
  • [49] Fire-damaged R/C members repair with high-performance fibre-reinforced jacket
    Department of Civil Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy
    Strain, SUPPL. 2 (28-35):
  • [50] Fire-damaged R/C Members Repair With High-Performance Fibre-Reinforced Jacket
    Leonardi, A.
    Meda, A.
    Rinaldi, Z.