Repair of fire-damaged RC square columns with CFRP textile-reinforced ECC matrix

被引:16
|
作者
Liu, Wang-Wei [1 ,2 ]
Ouyang, Li-Jun [3 ]
Gao, Wan-Yang [1 ,2 ]
Liang, Jian [1 ,2 ]
Wang, Tian-Ci [1 ,2 ]
Song, Jiang [1 ,2 ]
Yang, Jian [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai Key Lab Digital Maintenance Bldg & Infras, Shanghai 200240, Peoples R China
[3] Univ Shanghai Sci & Technol, Sch Environm & Architecture, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
RC columns; Fire damage; Strengthening; ECC; Textile; Axial compressive behavior; ENGINEERED CEMENTITIOUS COMPOSITE; CONCRETE COLUMNS; FRP CONFINEMENT; BEAMS; BEHAVIOR; BASALT; CAPACITY; MORTAR; STRAIN; MODEL;
D O I
10.1016/j.engstruct.2023.116530
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber-reinforced polymer (FRP) textile reinforced engineered cementitious composite (ECC) matrix (TRE for short) is a newly developed composite system with great potential for the strengthening and life extension of damaged reinforced concrete (RC) columns after fire exposure. It combines the advantages of the lightweight and high strength of FRP textile and the ultra-high ductility of ECC material. However, there is a lack of research on the use of the TRE system to strengthen fire-damaged RC columns. This paper presents an experimental study on the axial compressive behavior of fire-damaged square RC columns strengthened with the TRE system. A total of 13 specimens were prepared and tested under axial compression. The test variables included the fire-exposure time (2 h or 3 h) used to produce the initial pre-damage of RC columns, the type of cementitious matrix (ECC or mortar), the number of TRE layers (2 layers or 3 layers), and the thickness of the concrete cover (20 mm or 40 mm). The failure modes, load capacity, secant stiffness, ultimate displacement, load-displacement curves of the specimens and the hoop tensile strains in the outermost layer of the CFRP textiles were investigated and discussed. The typical failure mode of the strengthened specimens was characterized by tensile rupture of the fiber rovings bridging the main crack in the strengthening jacket. The results showed that the use of the TRE system could significantly increase the load capacity, secant stiffness and ultimate displacement of fire-damaged RC columns. Depending on the design parameters, the enhancement percentages in the load capacity varied between 18% and 126%.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Experimental research on fire-damaged RC continuous T-beams subsequently strengthened with CFRP sheets
    Xu, Qingfeng
    Chen, Lingzhu
    Han, Chongqing
    Harries, Kent A.
    Xu, Zhimin
    ENGINEERING STRUCTURES, 2019, 183 : 135 - 149
  • [32] Effects of long-term loading on fire-damaged reinforced-concrete stub columns
    Huo, Jingsi
    Liu, Hanqing
    Xu, Xi
    MAGAZINE OF CONCRETE RESEARCH, 2019, 71 (09) : 476 - 487
  • [33] A Comparative Study of Circular and Square RC Columns Externally Reinforced with CFRP Composite
    Benzaid, Riad
    Mesbah, Habib-Abdelhak
    Chikh, Nasr-eddine
    7TH ASIAN SYMPOSIUM ON POLYMERS IN CONCRETE, 2012, : 893 - 901
  • [34] Experimental research on eccentric compression performance of fire-damaged RC lattice columns strengthened with filling concrete
    Han C.
    Shao P.
    Xu Q.
    Chen L.
    Cheng J.
    Leng Y.
    Xu, Qingfeng (xuqingfeng73@163.com), 1600, Science Press (42): : 169 - 178
  • [35] Repair of fire damaged circular reinforced concrete columns with FRP composites
    Yaqub, M.
    Bailey, C. G.
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (01) : 359 - 370
  • [36] Study on seismic behavior of low ductility RC columns strengthened with textile-reinforced concrete composites
    Zhang Q.
    Zhu X.
    Gu X.
    Xie Y.
    Zhao Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (12): : 49 - 58
  • [37] Repair of fire damaged circular reinforced concrete columns with FRP composites
    University of Manchester, Sackville Street Building, Oxford Road, Manchester, M13 9PL, United Kingdom
    Constr Build Mater, 1 (359-370):
  • [38] Repair of heat-damaged RC columns using carbon nanotubes modified CFRP
    Irshidat, Mohammad R.
    Al-Saleh, Mohammed H.
    MATERIALS AND STRUCTURES, 2017, 50 (02)
  • [39] Repair of heat-damaged RC columns using carbon nanotubes modified CFRP
    Mohammad R. Irshidat
    Mohammed H. Al-Saleh
    Materials and Structures, 2017, 50
  • [40] Slenderness effects on concrete-filled square steel tube columns strengthened with CFRP grid-reinforced ECC matrix
    Yan, Yuhong
    Ma, Wentao
    Lu, Yiyan
    Li, Shan
    Huang, Yue
    ENGINEERING STRUCTURES, 2024, 314