Aortic arch branching variations and risk of cerebrovascular accidents in patients with a left ventricular assist device

被引:0
|
作者
Zijderhand, Casper F. [1 ,3 ]
Sjatskig, Jelena [1 ]
Scharink, Denne A. [1 ]
Peek, Jette J. [1 ]
Birim, Ozcan [1 ]
Bekkers, Jos A. [1 ]
Bogers, Ad J. J. C. [1 ]
Caliskan, Kadir [2 ]
机构
[1] Erasmus MC Univ Med Ctr, Dept Cardiothorac Surg, Thoraxcenter, Rotterdam, Netherlands
[2] Erasmus MC Univ Med Ctr, Dept Cardiol, Rotterdam, Netherlands
[3] Erasmus MC, Thoraxcenter, Univ Med Ctr Rotterdam, Room RG-620,Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands
关键词
adverse events; anatomic variations; aortic arch branching; left ventricular assist device; STROKE; COMPLICATIONS; MORTALITY; SUPPORT; EVENTS; IMPACT;
D O I
10.2459/JCM.0000000000001570
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This retrospective study investigated the association between anatomical variations in the aortic arch branching and adverse events, including the risk of cerebrovascular accidents (CVAs), in patients with a left ventricular assist device (LVAD).Methods Medical charts were reviewed for all patients with HeartMate 3 LVAD support at our center from 2016 to 2021. Computed tomography scans were evaluated to categorize the variations in the aortic arch branching based on seven different types, as described in the literature.Results In total, 101 patients were included: 86 (85.1%) with a normal branching pattern and 15 (14.9%) with an anatomical variation. The following variations were observed: eight (7.9%) with a bovine arch and seven (6.9%) with a left vertebral arch. The median age was 57 years, 77.2% were men, and the median follow-up was 25 months. No difference was found in the rate of early (< 30 days) re-exploration due to bleeding after LVAD implantation. The rate of CVA and mortality did not differ significantly between patients with a normal arch or an anatomical variation during follow-up, with hazard ratios of 1.47 [95% confidence interval (CI): 0.48-4.48; P = 0.495] and 0.69 (95% CI: 0.24-1.98; P = 0.489), respectively.Conclusion This preliminary study showed no differences in early and long-term adverse events, including CVA, when comparing patients with a variation in the aortic arch branching to patients with a normal aortic arch. However, knowledge of the variations in aortic arch branching could be meaningful during cardiac surgery for potential differences in surgical events in the perioperative period.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 50 条
  • [41] Ventricular Arrhythmias in Patients With Left Ventricular Assist Device (LVAD)
    Ahmed, Azza
    Amin, Mustapha
    Boilson, Barry A.
    Killu, Ammar M.
    Madhavan, Malini
    CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE, 2019, 21 (11)
  • [42] Ventricular Arrhythmias in Patients With Left Ventricular Assist Device (LVAD)
    Azza Ahmed
    Mustapha Amin
    Barry A. Boilson
    Ammar M. Killu
    Malini Madhavan
    Current Treatment Options in Cardiovascular Medicine, 2019, 21
  • [43] Low thromboembolic risk for patients with the Heartmate II left ventricular assist device
    John, Ranjit
    Kamdar, Forum
    Liao, Kenneth
    Colvin-Adams, Monica
    Miller, Leslie
    Joyce, Lyle
    Boyle, Andrew
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05): : 1318 - 1323
  • [44] Risk factor analysis of Swedish left ventricular assist device (LVAD) patients
    Granfeldt, H
    Koul, B
    Wiklund, L
    Peterzén, B
    Lönn, U
    Babic, A
    Ahn, HC
    ANNALS OF THORACIC SURGERY, 2003, 76 (06): : 1993 - 1998
  • [45] Current Smoking and Increased Risk of Stroke in Patients with Left Ventricular Assist Device
    Sherazi, S.
    Goldenberg, I.
    McNitt, S.
    Kutyifa, V.
    Gosev, I.
    Wood, K.
    Chen, L.
    Polonsky, S.
    Vidula, H.
    Alexis, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S171 - S171
  • [46] Diabetes Mellitus Is Not a Risk Factor for Patients Supported With Left Ventricular Assist Device
    Zhou, Pengyu
    Xiao, Zezhou
    Zhu, Peng
    Nie, Zhiqiang
    Pavan, Desai
    Zheng, Shaoyi
    ANNALS OF THORACIC SURGERY, 2020, 109 (05): : 1614 - 1622
  • [47] VAD-Related and Specific Infections are Significantly Associated with an Increased Risk of Cerebrovascular Accidents in Patients Supported by a Ventricular Assist Device: An EUROMACS Analysis
    Antonides, C.
    Veen, K.
    Schoenrath, F.
    Gummert, J.
    Nemec, P.
    Merkely, B.
    Musumeci, F.
    Meyns, B.
    de By, T.
    Bogers, A.
    Caliskan, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S44 - S45
  • [48] Left ventricular assist device implantation in patients after left ventricular reconstruction
    Palmen, Meindert
    Braun, Jerry
    Beeres, Saskia L. M. A.
    Klautz, Robert J. M.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (06) : 979 - 981
  • [49] Aortic Arch And Variations In Its Branching Pattern
    Indumathi, S.
    Sudha, S.
    Rajila, Hannah Sugirthabai R.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2010, 4 (05) : 3134 - U449
  • [50] Anatomical Variations in Aortic Arch Branching Pattern
    Kondori, Bahman Jalali
    Asadi, Mohammad Hossein
    Rahimian, Elham
    Tahsini, Majid Reza